Gold Member Since 2010
Audited Supplier
Zhejiang Cen New Energy Technology Co., Ltd.

Swimming Pool Heat Pump, Heat Pump for Swimming Pool, Pool Heating Water Heater manufacturer / supplier in China, offering Swimming Pool Heat Pump Water Heater, Evi Air Source Heat Pump for Hot Water&Space Heating 12kw-D03h, Air Source Heat Pump Water Heater Circulating Type, with Copeland Compressor and so on.

(/ )

Supplier Homepage Product Swimming pool heat pump Swimming Pool Heat Pump Water Heater

Swimming Pool Heat Pump Water Heater

FOB Price: Get Latest Price
Min. Order: 1 Piece
Production Capacity: 1, 000 PCS/Month
Transport Package: Safe Export Packing
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: CKFCRS-120II
  • Heat Temperature: 50-70°C
  • Heat Source: Air-source
  • Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
  • Cabient Colour: White or Black
  • Rated Power: 24.0kw
  • Noise: 70db(a)
  • Specification: CE
  • Energy Efficiency Grade: One
  • Work Environment: Common Heat Pump
  • Heating Type: Circulating Heat
  • Certification: CE, ISO9001, CCC, SASO
  • Rated Heating Capacity: 120kw
  • Performance Coefficient(Cop): 5.0
  • Trademark: KONNEN
  • Origin: China
Product Description
Swimming Pool Heat Pump 120KW:

1. Controlled by many modular machines, it has high water yield, adopts titanium, plate type and shell-tube heat excha



nger and resists corrosion, safe and durable and higher in energy efficiency.

2. With automatic heating and thermostatic control, it can provide hot water and ice water, ensuring dual-safety enjoyment.

3. The unit has the magnetic device, making H2O and metal ions arrange orderly. The magnetized water is regarded as a good skin care product in the medicine.

4. The titanium metal heat exchanger has strong anticorrosion capacity, high water-yielding capacity and thermal efficiency reaching 5.0. It is the first choice of constant temperature heating of the swimming pool.
S02H series(Swimming pool heat pump)                                                                                                                                                                                                        SP-150301

SP2.5PS-H2SP03PS-E3SP05PS-E5SP03P-E3SP05P-E5SP07P-E5SP10P-C24SP14P-C24SP20P-C48SP24P-C48SP30P-C48SP36P-C96SP40P-C96SP48P-C96
Rated heating capacitykW12 14 24 14 24 32 48 66 95 115 145 170 190 230 
Rated input powerkW2.11 2.45 4.14 2.37 4.06 5.69 8.14 11.57 16.10 19.49 25.11 29.31 32.76 39.65 
Rated input currentA10.82 12.56 21.23 4.55 7.80 10.92 15.63 22.21 30.91 37.42 48.21 56.28 62.90 76.13 
COP /5.59 5.71 5.80 5.91 5.91 5.62 5.90 5.70 5.90 5.90 5.77 5.80 5.80 5.80 
*Heating capacitykW12 20 12 20 25 40 52 80 95 120 145 160 190 
*Input powerkW1.80 2.30 3.88 2.33 3.80 4.87 7.62 9.98 15.36 18.20 22.81 27.83 30.48 36.19 
*Input currentA9.21 11.81 19.92 4.47 7.30 9.36 14.63 19.16 29.48 34.94 43.80 53.44 58.51 69.49 
*COP/5.01 5.21 5.15 5.15 5.26 5.13 5.25 5.21 5.21 5.22 5.26 5.21 5.25 5.25 
Maximum input powerkW2.74 3.19 5.38 3.08 5.28 7.40 10.58 15.04 20.93 25.34 32.64 38.10 42.59 51.55 
Maxmum input currentA14.05 16.33 27.60 5.92 10.13 14.20 20.32 28.88 40.19 48.65 62.67 73.16 81.77 98.97 
Rated hot water output temperature'ºC28 
Maximum hot water output temperatureºC35 
Power supply1N 220V/50Hz3N 380V/50Hz
CompressorTypeRotor typeFully closed scroll type
Start modeDirectly start
QuantitySet11111122223344
Water side heat exchangerTypeTitanium tube heat exchanger
Water flowM3/h5.07 6.02 10.32 6.02 10.32 13.76 20.6428.3840.8549.45 62.35 73.10 81.70 98.90 
 Water pressure dropKPa≤50≤70
Pipe sizeΦΦ50Φ50Φ50Φ50Φ50Φ50Φ50Φ50Φ50Φ90Φ90Φ110Φ110Φ110
Protections1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection,
8. Water flow protection etc.
NoiseDB(A)≤50≤55≤63≤55≤63≤63≤65≤68≤70≤72≤73≤74≤76≤78
Unit dimensionsmm1000×360×
630
700×700×
870
820×695×
1060
700×700×
870
820×695×
1060
820×695×
1060
1000×1000×18581000×1000×18581000×2050×19001000×2050×19001000×2050×19801000×2050×19802000×2050×19802000×2050×1980
WeightKG6410016010016016533536560066084086012251260
Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC
                             2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC
The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier
Avatar
Mr. Yanfen.Zhang
Export Manager
*From:
To: Mr. Yanfen.Zhang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now