Certification: SASO, CCC, ISO9001, CE, TUV
Working Medium: R410A
Heat Source Type: Air Source Heat Pump
Product Name: Air to Water Heat Pump Water Heater
Rated Outlet Hot Water Temperature: 55 Degree
Maximum Outlet Hot Water Temperature: 56 Degree
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RF7I/BR---RF17I/BR
Compressor
Gmcc
Refrigerant
R410A
Usage
Water Heater
Control Type
Digital
Display Type
LCD
Material
Colored Steel Casing
Working Range
-30--43 Degree
Power Supplier
220V/1/50Hz
Heating Capacity (Kw)
8.8kw-17kw
Power Input (Kw)
2.55-4.91
Cooling Capacity (Kw)
8-12
Cooling Input(Kw)
3.2-4.8
Transport Package
Safe Export Packing
Specification
RF8I/bd--RF16I/bd
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
2500units/Month

Product Description

KONNEN DC INVERTER AIR SOURCE HEAT PUMP, FOR COOLING +HEATING:
* MOQ: 5PC each model
* Working temp at -20ºC ~43ºC.;
*With wifi function
* MISUBISHI compressor with R32 refrigerant ;
* Delivery time:about 40days after received deposit;
* Payment:T/T 30% prepaid ,then pay for the balance before delivery;
*Package:ply-wood cases;
* Warrenty:18month;

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
R32 DC Inverter Heat Pump for House Heating & Cooling
WHY US:
R32 DC Inverter Heat Pump for House Heating & Cooling
KONNEN NEW PROJECTS:
R32 DC Inverter Heat Pump for House Heating & Cooling
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
R32 DC Inverter Heat Pump for House Heating & Cooling
KONNEN HEAT PUMPS LOADING:
R32 DC Inverter Heat Pump for House Heating & Cooling
PARAMETERS TABLE:
Monoblock R32 refrigerant DC inverter heat pump with WiFi function (heating, cooling and DHW)
Model number RF7I/BR RF9I/BR RF13I/BR RF17I/BR
Heating at A7/W35
 Heating capacity (min~max) KW 6.80 (3.36~7.93) 9.00 (4.50~10.66) 12.80 (6.05~14.30) 17.00 (8.60~20.30)
 Power input (min~max) KW 1.62 (0.82~1.91) 2.05 (1.07~2.50) 2.97 (1.51~3.52) 3.86 (1.91-4.45)
COP  W/W 4.20 (3.30~5.40) 4.40 (3.30~5.30) 4.30 (3.20~5.20) 4.40 (3.30~5.50)
Heating at A2/W35
Heating capacity (min~max) KW 6.25 (2.92~7.42) 8.32 (3.74~9.52) 11.80 (5.30~13.30) 15.70 (7.37~18.80)
 Power input  (min~max) KW 1.60 (0.82~1.96) 2.03 (1.02~2.45) 2.95 (1.45~3.50) 3.84 (1.89~4.56)
COP W/W 3.90 (2.30~4.60) 4.10 (2.40~4.60) 4.00 (2.20~4.40) 4.10 (2.40~4.80)
Heating at A-7/W35
Heating capacity (min~max) KW 5.03 (2.52~5.90) 6.53 (3.28~7.71) 9.64 (4.85~11.38) 12.65 (6.34~14.93)
 Power input (min~max) KW 1.57 (0.79~1.96) 1.98 (0.99~2.48) 2.92 (1.46~3.45) 3.72 (1.86~4.65)
COP W/W 3.20 (2.56~3.84) 3.30 (2.64~3.96) 3.30 (2.64~3.95) 3.40 (2.72~4.08)
Cooling at A35/W7
Cooling capacity (min~max) KW 5.00 (2.75~6.50) 6.50 (3.58~8.45) 10.20 (5.61~13.26) 12.90 (7.10~18.7)
power input (min~max) KW 1.78 (1.07~2.58) 2.28 (1.37~3.31) 3.64 (2.18~5.28) 4.45 (2.67~6.45)
EER W/W 2.80 (2.40~3.15) 2.85 (2.45~3.15) 2.80 (2.40~3.10) 2.90 (2.45~3.20)
 
Power supply V/Ph/Hz 220~240/1/50 220~240/1/50 220~240/1/50 380~415/3/50
Compressor N/A MISUBISHI MISUBISHI MISUBISHI MISUBISHI
Compressor type N/A DC Inverter DC Inverter DC Inverter  DC Inverter
Compressor quantity pc 1 1 1 1
Fan type N/A DC Inverter DC Inverter DC Inverter DC Inverter
Fan quantity pc 1 1 2 2
Refrigerant N/A R32 R32 R32 R32
Refrigerant regulation N/A Electronic expansion valve
Defrosting  N/A Auto-defrosting Auto-defrosting Auto-defrosting Auto-defrosting
Heat exchanger  N/A SWEP SWEP SWEP SWEP
Heat exchanger type N/A Brazed plate heat exchanger
Water connection Inch 1 1 1 1
Water flow switch N/A SIKA SIKA SIKA SIKA
Norminal water flow m3/h 1.4 1.8 2.7 3.6
Operating outdoor temperature ºC -20~43 -20~43 -20~43 -20~43
Max heating water temperature ºC 60 60 60 60
Max DHW temperature ºC 55 55 55 55
Min cooling water temperature ºC 10 10 10 10
Sound level dB(A) 52 54 56 56
Degree of protection N/A IPX4 IPX4 IPX4 IPX4
Net weight  kg 57 72 102 122
Dimension mm 945*410*600 1010*410*795 1115*470*1020 1165*470*1280
Test condition:          
1. A7/W35: outdoor air temperature 7ºC DB/6ºC WB, water inlet/outlet temperature 30ºC/35ºC          
2. A2/W35: outdoor air temperature 2ºC DB/1ºC WB, water inlet/outlet temperature 30ºC/35ºC          
3. A-7/W35: outdoor air temperature -7ºC DB/-8ºC WB, water inlet/outlet temperature 30ºC/35ºC          