• Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees C
  • Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees C
  • Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees C
  • Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees C
  • Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees C
  • Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees C

Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees C

Energy Efficiency Grade: One
Heat Temperature: 28~35 Degrees C
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Certification
CE, ISO9001, CCC, SASO
Compressor
Copeland or SANYO or Panasonic
Color
White
Refrigerant
R417A/R410A/R22
Capacity
8kw to 230kw
Expansion Valve
Eev
Quality Control
Tested in National Proved Laboratory
Heat Exchanger
High Quality Titanium Tube Heat Exchanger
Transport Package
Strong & Safety Export Packing
Specification
CE
Trademark
KONNEN
Origin
Zhejiang, China
HS Code
8418612090
Production Capacity
1000 Units/Month

Product Description

     Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees CAir Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees CLarge Power Air Source Heat Pump Swimming Pool for Outdoor:

  • CE approved

  • Long time of warranty

  • Machine casing: spray coating metal plate

  • Function: Production of hot water

  • Host machine color: white or grey

  • Accessories: LCD controller, pressurized water tank(150L, 200L, 300L, 500L)

  • Safety protecting system:

  • 1)High and low pressure protection

  • 2)Anti-freeze protection

  • 3)High temperature protection

  • 4)Safety valve

  • 5)Overload protection

  • 6)Reverse phase

  • 7)Lack of phase

  • 8)Separation of water and electricity

  • 9)Air to Water Heat Pump for Commercial Use

  • Refrigerant: R22/R410
     

 A02H series (Air source heat pump water heater circulation type)                                                                                                                                          HW-150304
  HW03Ps-E3 HW05Ps-E5 HW03P-E3  HW05P-E5 HW07P-E5 HW10P-C24 HW14P-C24 HW20P-C48 HW24P-C48 HW30P-C48 HW36P-C48 HW48P-C96
Rated heating capacity kW 12 19 12 19 25 35 50  75 85 105 125 165
Rated input power kW 2.75  4.39  2.75  4.37  5.75  8.10  11.57  17.20  19.60  24.20  28.90  38.10 
Rated input current A 14.05  23.10  5.17  8.34  10.77  15.00  23.86  31.80  37.00  46.10  53.50  72.30 
Maximum input power kW 3.38  5.40  3.38  5.38  7.07  9.96  14.23  21.16  24.11  29.77  35.55  46.86 
Maximum input current A 18.28  29.19  6.43  10.21  13.44  18.93  27.05  40.20  45.81  56.56  67.54  89.04 
Performance coefficient(COP) / 4.36  4.33  4.36  4.35  4.35  4.33  4.32  4.36  4.34  4.34  4.33  4.33 
Rated hot water output temp. ºC 55 
Max. hot water output temp. ºC 60 
Rated hot water produce capacity L/H 258 408 258 408 537 752.5 1075 1612.5 1827.5 2257.5 2687.5 3547.5
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Fully closed scroll type
Start Mode Directly start
Quantity Set 1 1 1 1 1 2 2 4 2 3 3 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 2.1  3.3  2.1  3.3  4.3  6.0  8.6  12.9  14.6  18.1  21.5  28.4 
Water Pressure Drop kPa ≤50 ≤55 ≤50 ≤55 ≤55 <60 <60 <65 <65 <65 <65 <65
Pipe size DN DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN65 DN80
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Refrigerant Throttle Type Electronic expansion valve
Quantity kg 1.9 2.8 1.9 2.8 4.1 2.8×2 4.1×2 3.2×4 7.6×2 6.2×3 7.6×3 7.6×4
Noise DB(A) ≤55 ≤63 ≤55 ≤63 ≤65 ≤65 ≤68 ≤70 ≤72 ≤73 ≤74 ≤78
Dimension mm 700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1060
1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1980 1000×2050×1980 2000×2050×1980
Net Weight kg 100 160 100 160 190 310 400 605 650 835 840 1230
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. 
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.
 
R&D team with long time experience for heat pump water heaters and electronic controls:
Three main factories for heat pump water heater, water tank, and control system,
25HP national proved Laboratory for heat pump water heater,
Famous brand of components we use:
Air Source Heat Pump Water Heater for Swimming Pool Water From 28 to 35 Degrees C
air source heat pump, air to water heat pump water heater.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now