Gold Member Since 2010
Audited Supplier
Zhejiang Cen New Energy Technology Co., Ltd.

Heat Pump, Air Source Heat Pump, Air to Water Heat Pump manufacturer / supplier in China, offering Large Power Air Source Heat Pump Swimming Pool for Outdoor, Swimming Pool Heat Pump-24kw-S02h, Circulating Type Home Use Heat Pump Water Heater (CKXRS-5.0IH) and so on.

(/ )

Supplier Homepage Product Air source commercial use heat pump Large Power Air Source Heat Pump Swimming Pool for Outdoor

Large Power Air Source Heat Pump Swimming Pool for Outdoor

FOB Price: US $2,590 / Set
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $2,590/ Set
Get Latest Price
Production Capacity: 50 Units/Day
Transport Package: Plywood Case and Pallet Packing
Payment Terms: L/C, T/T, D/P, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HW10P-C24
  • Heat Temperature: 50-70°C
  • Heat Source: Air-source
  • Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
  • Outlet Water Max Temp: 60 Celsius Degree
  • Outlet Water Rated Temperature: 55 Celsius Degree
  • Product Name: Air Source Heat Pump for Commercial Use
  • Type: Air Source Heat Pump
  • Specification: ISO9001, CE, CCC, TUV
  • HS Code: 8418612090
  • Energy Efficiency Grade: One
  • Work Environment: Common Heat Pump
  • Heating Type: Circulating Heat
  • Certification: CE, ISO9001, CCC, SASO
  • Rated Heating Capacity: 35 Kw
  • Outlet Hot Water Quantity (L/H): 752.5
  • Refrigerant: R410A
  • Trademark: KONNEN
  • Origin: China
Product Description

     Large Power Air Source Heat Pump Swimming Pool for Outdoor:

  • CE approved

  • Long time of warranty

  • Machine casing: spray coating metal plate

  • Function: Production of hot water

  • Host machine color: white or grey

  • Accessories: LCD controller, pressurized water tank(150L, 200L, 300L, 500L)

  • Safety protecting system:

  • 1)High and low pressure protection

  • 2)Anti-freeze protection

  • 3)High temperature protection

  • 4)Safety valve

  • 5)Overload protection

  • 6)Reverse phase

  • 7)Lack of phase

  • 8)Separation of water and electricity

  • 9)Air to Water Heat Pump for Commercial Use

  • Refrigerant: R22/R410
     

 A02H series (Air source heat pump water heater circulation type)                                                                                                                                          HW-150304
 HW03Ps-E3HW05Ps-E5HW03P-E3 HW05P-E5HW07P-E5HW10P-C24HW14P-C24HW20P-C48HW24P-C48HW30P-C48HW36P-C48HW48P-C96
Rated heating capacitykW12191219253550 7585105125165
Rated input powerkW2.75 4.39 2.75 4.37 5.75 8.10 11.57 17.20 19.60 24.20 28.90 38.10 
Rated input currentA14.05 23.10 5.17 8.34 10.77 15.00 23.86 31.80 37.00 46.10 53.50 72.30 
Maximum input powerkW3.38 5.40 3.38 5.38 7.07 9.96 14.23 21.16 24.11 29.77 35.55 46.86 
Maximum input currentA18.28 29.19 6.43 10.21 13.44 18.93 27.05 40.20 45.81 56.56 67.54 89.04 
Performance coefficient(COP)/4.36 4.33 4.36 4.35 4.35 4.33 4.32 4.36 4.34 4.34 4.33 4.33 
Rated hot water output temp.ºC55 
Max. hot water output temp.ºC60 
Rated hot water produce capacityL/H258408258408537752.510751612.51827.52257.52687.53547.5
Power supply1N 220V/50Hz3N 380V/50Hz
CompressorTypeFully closed scroll type
Start ModeDirectly start
QuantitySet111112242334
Water side heat exchangerTypeShell & coil(tube) heat exchanger
Water flowm3/h2.1 3.3 2.1 3.3 4.3 6.0 8.6 12.9 14.6 18.1 21.5 28.4 
Water Pressure DropkPa≤50≤55≤50≤55≤55<60<60<65<65<65<65<65
Pipe sizeDNDN20DN25DN20DN25DN25DN32DN32DN50DN50DN50DN65DN80
Protections1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
RefrigerantThrottle TypeElectronic expansion valve
Quantitykg1.92.81.92.84.12.8×24.1×23.2×47.6×26.2×37.6×37.6×4
NoiseDB(A)≤55≤63≤55≤63≤65≤65≤68≤70≤72≤73≤74≤78
Dimensionmm700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1060
1000×1000×18581000×1000×18581000×2050×19001000×2050×19001000×2050×19801000×2050×19802000×2050×1980
Net Weightkg1001601001601903104006056508358401230
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. 
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.
 
R&D team with long time experience for heat pump water heaters and electronic controls:
Three main factories for heat pump water heater, water tank, and control system,
25HP national proved Laboratory for heat pump water heater,
Famous brand of components we use:

Large Power Air Source Heat Pump Swimming Pool for Outdoor
air source heat pump, air to water heat pump water heater.
Send your message to this supplier
Avatar
Mr. Yanfen.Zhang
Export Manager
*From:
To: Mr. Yanfen.Zhang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now