Air-Cooled Module Units Heat Pump75kw
Water source heat pump for cooling and heating
|
CRF15I/J |
CRF15/J |
CRF30/JT |
CRF40/JT |
CRF55/JF |
CRF65/JF |
CRF75/JF |
CRF98/JF |
CRF130/JF |
(CF02F05A) |
(CF02F05B) |
(CF02F10A) |
(CF02F14A) |
(CF02F20A) |
(CF02F24A) |
(CF02F28A) |
(CF02F36A) |
(CF02F48A) |
cooling capacity |
kW |
15 |
15 |
30 |
40 |
55 |
68 |
75 |
98 |
130 |
heating capacity |
kW |
16 |
16 |
31 |
42 |
57 |
71 |
78 |
107 |
136 |
cooling input power |
kW |
4.7 |
4.7 |
9.5 |
12.7 |
17.5 |
21.6 |
23.8 |
31.2 |
41.3 |
heating input power |
kW |
4.8 |
4.9 |
9.5 |
12.9 |
17.6 |
21.9 |
24.1 |
33.1 |
41.9 |
cooling input current |
A |
24.1 |
8.9 |
17.9 |
23.9 |
32.9 |
40.7 |
44.8 |
58.6 |
77.8 |
heating input current |
A |
25.3 |
9.3 |
18.1 |
24.5 |
33.3 |
41.5 |
45.5 |
62.5 |
79.4 |
max. input power |
kW |
5.8 |
6 |
11.6 |
15.8 |
21.4 |
26.7 |
29.3 |
40.3 |
51.2 |
max. input current |
A |
30.1 |
11.2 |
21.7 |
29.4 |
40.1 |
49.8 |
54.7 |
75.1 |
95.4 |
energy regulation |
% |
0,100 |
0,50,100 |
0,25,50,75,100 |
power |
1N 220V/50Hz |
3N 380V/50Hz |
Alternative power |
(1N 208-230V/60Hz);(3N 208-230V/60Hz);(1N 220-240V/50Hz);(3N 220-240V/50Hz) |
(3N 208-230V/60Hz);(3N 380-415V/50Hz);(3N 440-460V/60Hz);(3N 380V/60Hz) |
compressor |
type |
Scroll type |
Start Method |
Direct Start |
quantity |
pcs |
1 |
1 |
2 |
2 |
4 |
4 |
4 |
4 |
4 |
Water side heat exchanger |
type |
plate type heat exchanger |
Shell and tube heat exchanger |
water flow |
m 3 /h |
2.58 |
2.58 |
5.16 |
6.88 |
9.46 |
11.696 |
12.9 |
16.856 |
22.36 |
pressure drop |
≤kPa |
40 |
40 |
40 |
40 |
50 |
50 |
50 |
50 |
50 |
pipe size |
mm |
DN25 |
DN32 |
DN50 |
connection pipe mode |
inner thread |
Flange |
Fan |
Type |
efficient axial type |
Wind out type |
wind blowing from the side |
wind blowing from the top |
refrigerant |
type |
R410A |
throttle type |
expansion valve |
quantity |
kg |
3.1 |
3.1 |
3.2×2 |
3.6×2 |
3.6×4 |
4.2×4 |
5.0×4 |
6.5×4 |
8.5×4 |
dimentions |
length |
mm |
933 |
933 |
1460 |
1460 |
2050 |
2050 |
2050 |
2050 |
2050 |
width |
mm |
403 |
403 |
910 |
910 |
1100 |
1100 |
1100 |
1100 |
1100 |
height |
mm |
1395 |
1395 |
1430 |
1430 |
1935 |
1935 |
1975 |
1980 |
2030 |
Noise |
≤dB(A) |
63 |
63 |
65 |
65 |
67 |
67 |
67 |
71 |
72 |
Weight |
kg |
140 |
140 |
299 |
299 |
650 |
650 |
710 |
820 |
940 |
Remarks:1.Cooling conditions: ambient dry bulb 35, cold water inlet 12, outlet 7. |
2. Heating conditions: ambient dry bulb 7, cold water inlet 40, outlet 45. |
3.The above models are for single module,it can be combined according to your requirment; |
4.The above models is our normal model,The product parameters may have some difference from the final produc. |