Swimming Pool Heat Pump Made by China Manufacturer
Reference FOB Price: | US $750.00-15,500.00 / Piece |
---|---|
Min. Order: | 1 Piece |
Energy Efficiency Grade: | One |
---|---|
Heat Temperature: | 28-35°c |
Work Environment: | Common Heat Pump |
Heat Source: | Air-source |
Heating Type: | Circulating Heat |
Application: | Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons |
Basic Info
Model NO.
SP14P-E10
Certification
CE, ISO9001, CCC, SASO, TUV
Heating Capacity
63kw
Product Name
Swimming Pool Heat Pump (9.45kw)
Rated Outlet Hot Water Temperature
28 Degree
Maximum Outlet Hot Water Temperature
35 Degree
Compressor
Panasonic /Copeland
Regrigerant
R410A
Transport Package
Safe Export Packing
Specification
SP14P-E10
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
28000PCS/Month
Product Description
KONNEN SWIMMING POOL HEAT PUMP, AIR TO WATER HEAT PUMP:
WE SUPPLY OEM SERVICE!
KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
WHY US:
KONNEN NEW PROJECTS:
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
KONNEN HEAT PUMPS LOADING:
PARAMETERS TABLE:
* Copeland /Panasonic compressor & R410a/R417a refrigerant. |
* Stainless steel 304 for all fasteners, for side covers of evaporator; |
* Preservative oil for copper tubes and all important part of cabinet; |
*Chinese No.1 brand "Gimleo" Titanium tube heat exchanger; |
* Japan "Saginomiya" or "Sanhua" electronic expansion valve; |
* "Sanhua" 4-way valve; |
* "Schneider" AC contactor & Relay |
* LCD controller; |
* Delivery time: 20~30 days; |
* Payment term: T/T 30% in advance and T/T 70% before delivery; |
* Warranty time: 24 months after delivery. |
WE SUPPLY OEM SERVICE!
KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
WHY US:
KONNEN NEW PROJECTS:
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
KONNEN HEAT PUMPS LOADING:
PARAMETERS TABLE:
Wave series(Swimming pool heat pump) | ||||||||||||||||
SP2.5PS-H2 | SP03PS-E3 | SP05PS-E5 | SP03P-E3 | SP05P-E5 | SP07P-E5 | SP10P-E10 | SP14P-E10 | SP20P-E20 | SP24P-E20 | SP30P-E20 | SP40P-C96 | SP48P-C96 | SP60P-C96 | |||
Rated heating capacity | kW | 11.8 | 13.8 | 24.1 | 13.8 | 24.1 | 31.5 | 47.5 | 63.3 | 92.8 | 112.6 | 143.3 | 190.0 | 230.0 | 280.0 | |
Rated input power | kW | 2.21 | 2.63 | 4.51 | 2.64 | 4.52 | 6.01 | 9.06 | 12.10 | 16.96 | 20.91 | 26.49 | 34.0 | 40.9 | 49.7 | |
Rated input current | A | 12.82 | 15.36 | 25.93 | 5.01 | 8.61 | 11.94 | 17.51 | 23.04 | 32.91 | 40.42 | 50.58 | 65.0 | 77.9 | 94.5 | |
COP | / | 5.34 | 5.25 | 5.34 | 5.23 | 5.33 | 5.24 | 5.24 | 5.23 | 5.47 | 5.38 | 5.41 | 5.6 | 5.6 | 5.6 | |
*Heating capacity | kW | 8.9 | 11.8 | 19.7 | 11.9 | 20.1 | 24.7 | 39.8 | 50.4 | 77.2 | 92.5 | 115.7 | 160.0 | 190.0 | 230.0 | |
*Input power | kW | 1.86 | 2.47 | 4.14 | 2.45 | 4.12 | 5.18 | 8.30 | 10.57 | 15.66 | 18.77 | 23.81 | 30.5 | 36.0 | 44.1 | |
*Input current | A | 10.66 | 14.24 | 23.65 | 4.70 | 7.82 | 9.85 | 15.98 | 20.12 | 29.85 | 35.65 | 45.35 | 58.0 | 68.9 | 83.7 | |
*COP | / | 4.78 | 4.78 | 4.76 | 4.86 | 4.88 | 4.77 | 4.80 | 4.77 | 4.93 | 4.93 | 4.86 | 5.3 | 5.3 | 5.2 | |
**Cooling capacity | kW | 8.74 | 11.65 | 19.42 | 11.65 | 19.42 | 24.27 | 38.83 | 50.49 | 77.67 | 92.23 | 116.50 | 155.35 | 184.47 | 220.25 | |
**Input power | kW | 2.33 | 3.08 | 5.06 | 3.04 | 5.08 | 6.34 | 10.25 | 13.25 | 20.39 | 24.21 | 30.66 | 40.98 | 48.92 | 58.27 | |
**Input current | A | 12.26 | 16.22 | 26.61 | 5.78 | 9.66 | 12.04 | 19.47 | 25.18 | 38.73 | 46.00 | 58.25 | 77.87 | 92.96 | 110.67 | |
**EER | / | 3.75 | 3.78 | 3.84 | 3.83 | 3.82 | 3.83 | 3.79 | 3.81 | 3.81 | 3.81 | 3.80 | 3.79 | 3.77 | 3.78 | |
Maximum input power | kW | 2.87 | 3.42 | 5.86 | 3.43 | 5.88 | 7.81 | 11.78 | 15.73 | 22.05 | 27.18 | 34.44 | 44.2 | 53.1 | 62.8 | |
Maxmum input current | A | 14.05 | 16.33 | 27.60 | 5.92 | 10.13 | 14.20 | 20.32 | 28.88 | 40.19 | 48.65 | 62.67 | 81.8 | 99.0 | 120.2 | |
Rated hot water output temperature | ºC | 28 | ||||||||||||||
Maximum hot water output temperature | ºC | 40 | ||||||||||||||
Rated cooling water output temperature | ºC | 12 | ||||||||||||||
Power supply | 1N 220V/50Hz | 3N 380V/50Hz | ||||||||||||||
Compressor | Type | Rotor type | Hermetic scroll type | |||||||||||||
Start mode | Directly start | |||||||||||||||
Quantity | Set | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 4 | 4 | 4 | 4 | 4 | 4 | |
Water side heat exchanger | Type | Titanium tube heat exchanger | ||||||||||||||
Water flow | M3/h | 5.07 | 6.02 | 10.32 | 6.02 | 10.32 | 13.76 | 20.64 | 28.38 | 40.85 | 49.45 | 62.35 | 81.70 | 98.90 | 124.70 | |
Water pressure drop | KPa | ≤50 | ≤70 | |||||||||||||
Pipe size | Φ | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ90 | Φ90 | Φ90 | Φ110 | Φ110 | Φ110 | |
Protections | 1. High pressure and low pressure protection, 2. Anti-freezing protection, 3. High temperature protection, 4. Too big of the water temperature difference for outlet and inlet protection, 5. Overload protection, 6. Lack phase protection, 7. Reverse phase protection, 8. Water flow protection etc. | |||||||||||||||
Noise | DB(A) | ≤50 | ≤55 | ≤63 | ≤55 | ≤63 | ≤63 | ≤65 | ≤68 | ≤70 | ≤70 | ≤70 | ≤76 | ≤78 | ≤80 | |
Unit dimensions | mm | 1000×360× 630 | 700×700× 870 | 820×695× 1060 | 700×700× 870 | 820×695× 1060 | 820×695× 1060 | 1502×750×1060 | 1502×750×1060 | 1995×1165×1105 | 1995×1165×1105 | 1995×1165×1105 | 2000×2050×1980 | 2000×2050×1980 | 2000×2050×1980 | |
Weight | KG | 64 | 100 | 160 | 100 | 160 | 190 | 255 | 400 | 600 | 725 | 855 | 1225 | 1260 | 1310 | |
Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC. | ||||||||||||||||
2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC. | ||||||||||||||||
3. ** Cooling: Ambient temp.(DB/WB): 35ºC/24ºC; Water temp.(In/Out):29ºC/27ºC | ||||||||||||||||
Cooling function for option, if your require cooling function, please let us know in advance. | ||||||||||||||||
The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us. | ||||||||||||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret. |