Water Source Heat Pump Water Heater Large Heating Capacity 240kw

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 40-60ºC
Still deciding? Get samples of US$ 1200/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Water Source Heat Pump Water Heater Large Heating Capacity 240kw
  • Water Source Heat Pump Water Heater Large Heating Capacity 240kw
  • Water Source Heat Pump Water Heater Large Heating Capacity 240kw
  • Water Source Heat Pump Water Heater Large Heating Capacity 240kw
  • Water Source Heat Pump Water Heater Large Heating Capacity 240kw
Find Similar Products

Basic Info.

Model NO.
CSFXRS-240II
Work Environment
Common Heat Pump
Heat Source
Water-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, SASO, TUV
Rated Heating Capacity
8kw-240kw
Refrigerant
R410A
Transport Package
Plywood Case or Carton
Specification
CSFXRS-8I--CSFXRS-240II
Trademark
KONNEN
Origin
Zhejiang, China
HS Code
8418612090
Production Capacity
2800units/Month

Product Description

KONNEN WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, WITH COPELAND COMPRESSOR AND R410A REFRIGERANT:
* Panasonic compressor & R410a refrigerant or Copeland compressor & R410a refrigerant;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Schneider AC contactor and relay
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* KONNEN LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY 2017(HEAT PUMP + WATER TANK + CONTROLLER):

Water Source Heat Pump Water Heater Large Heating Capacity 240kw
WHY US:
Water Source Heat Pump Water Heater Large Heating Capacity 240kw
KONNEN NEW PROJECTS:
Water Source Heat Pump Water Heater Large Heating Capacity 240kwKONNEN HEAT PUMPS FOR EXPORTING:
Water Source Heat Pump Water Heater Large Heating Capacity 240kw

WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Water Source Heat Pump Water Heater Large Heating Capacity 240kw
PRODUCT FEATURES:
Water Source Heat Pump Water Heater Large Heating Capacity 240kw

PARAMETERS TABLE:
Geothermy series (Water / Ground source heat pump water heater)
  CSFXRS-8I CSFXRS-10I CSFXRS-12I CSFXRS-20I CSFXRS-12II CSFXRS-20II CSFXRS-28II CSFXRS-40II CSFXRS-55II CSFXRS-80II CSFXRS-95II CSFXRS-120II CSFXRS160II CSFXRS190II CSFXRS240II
Rated heating capacity KW 7.9 9.8 11.8 19.8 11.9 19.8 28.1 39.5 54.3 79.2 93.95 118.85 158.2 188.8 238.4
Rated power KW 1.64  2.03  2.45  4.09  2.45  4.09  5.79  8.18  11.28  16.45  19.57  24.61  32.75  38.92  49.36 
Rated current A 8.77  11.53  13.92  23.24  4.62  7.77  10.99  15.54  21.97  31.12  37.16  46.74  62.19  73.92  93.75 
Maximum power KW 2.21  2.71  3.25  5.42  3.28  5.52  7.81  11.04  15.22  22.14  26.42  33.22  44.22  52.51  66.63 
Maximum current A 11.82  15.32  17.38  30.79  6.23  10.48  14.83  20.97  29.65  41.99  50.51  63.09  83.98  99.72  126.55 
Performance coefficient COP 4.82  4.83  4.82  4.84  4.86  4.84  4.85  4.83  4.81  4.81  4.80  4.83  4.83  4.85  4.83 
Rated hot water produce capacity L/H 172 215 258  430  258  430  602  860  1182  1720  2043  2580  3440  4085  5150 
Rated hot water output tempemperature ºC 55
Maximum hot water output temperature ºC 60
Power supply 1N 220V~240V/50Hz 3N 380V~420V/50Hz
Compressor Type Rotor type Hermetic scroll type
Start mode Directly Start(Soft start for option)
Hot water side heat exchanger Type Shell & tube heat exchanger
Water flow M3/h 1.4 1.8 2.1  3.4  2.1  3.4  4.8  6.9  9.4  13.8  16.3  20.6  27.5  32.7  41.2 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70 ≤70
Pipe connection DN DN20 DN20 DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN80 DN80 DN80
Pipe type Inner thread Flange
Heat source side heat exchanger Type Plate type heat exchanger Tube in tube heat exchanger Shell & tube heat exchanger
Water flow M3/h 1.1 1.4 1.6  2.7  1.6  2.7  3.8  5.4  7.3  10.7  12.7  16.1  21.5  25.5  32.3 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70 ≤70
Pipe size DN DN20 DN20 DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN80 DN80 DN80
Pipe connection Inner thread Flange
Protections 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.
Refrigerant Type R410A
Quantity(KG) 1.2 1.3 1.7 2.8 1.7 2.6 3.8 2.6x2 3.8x2 6x2 7.2x2 9x2 6x4 7.5x4 9x4
Noise ≤DB(A) 51 51 52 55 52 55 58 58 62 64 65 68 71 72 73
Unit dimensions Length MM 706 706 956 956 956 956 956 1100 1100 1795 1795 1795 2752 2752 2752
Width MM 356 356 556 556 556 556 556 840 840 1116 1116 1116 1178 1178 1178
Height MM 591 591 680 680 680 680 680 800 800 1049 1049 1049 1201 1201 1201
Weight KG 55 58 65 93 65 93 128 180 220 700 730 780 1300 1400 1500
Note: 1. Hot water heating standard condition: Hot water side initial water temperature 15ºC, final water temperature 55ºC;  heat source side water input temperature 15ºC.
2. The above parameters are based on refrigerant R410A, for parameters based on other refrigerant please contact us.
3.  The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier