Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Still deciding? Get samples of US$ 1400/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump
  • Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump
  • Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump
  • Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump
Find Similar Products

Basic Info.

Model NO.
EVI5P
Work Environment
Low-temperature Heat Pump
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC
Rated Heating Capacity
12kw, 19kw, 35kw
Compressor
Copeland
Type
Side Blowing
Cop at Ambient Temp. -25c
2.4
Transport Package
Safe Export Packing, with Pallet
Specification
CE
Trademark
KONNEN
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
2000 Units/Month

Product Description

KONNEN EVI AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP,LOW TEMPERATURE TYPE:
* Copeland compressor & R410a /R407C refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Packed with 3-way valve;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump
WHY US:
Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump
KONNEN NEW PROJECTS:
Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump

KONNEN HEAT PUMPS LOADING:
Air to Water Heat Pump Water Heater with Copeland Evi Air Source Heat Pump
PARAMETERS TABLE:
A02U series( EVI air source heat pump low temperature type)                                                                               EVI-150307
  EVI3P-S5 EVI5P-S5 EVI7P-E5 EVI10P-C24 EVI14P-C24 EVI20P-C48 EVI30P-C48 EVI40P-C96 EVI48P-C96
Normal condition Heating capacity kW 12 19 25 36 51 75 105 145 165
Input power kW 2.80  4.40  6.10  8.20  11.85  17.10  24.10  33.20  38.10 
Input current A 5.30  8.60  12.00  14.80  22.58  33.00  45.10  62.50  72.30 
COP / 4.29  4.32  4.32  4.39  4.24  4.39  4.36  4.37  4.33 
Nominal  condition Rated heating capacity kW 9.50  15.00  21.00  30.00  42.00  60.00  90.00  120.00  144.00 
Rated input power kW 2.60  4.10  5.70  8.10  11.34  16.10  24.50  32.50  39.30 
Rated input current A 5.20  8.20  11.40  15.30  21.42  30.20  46.00  61.10  73.60 
COP / 3.65  3.66  3.66  3.70  3.70  3.73  3.67  3.69  3.66 
Low temperature condition Heating capacity kW 5.50  8.80  12.30  17.50  24.50  36.50  52.50  70.00  84.00 
Input power kW 2.26  3.65  5.10  7.30  10.22  15.10  21.60  29.10  34.90 
Input current A 4.29  6.93  9.70  13.00  18.20  28.10  40.80  54.80  65.70 
COP / 2.43  2.41  2.41  2.40  2.40  2.42  2.43  2.41  2.41 
Maximum input power/current kW/A 3.61/6.92 5.71/11.20 7.99/15.68 10.62/20.75 15.42/30.08 22.27/43.36 31.38/612 42.92/83.62 51.5/100.3
Rated hot water output temperature ºC 55
Maximum hot water output temperature ºC 60
Rated hot water produce capacity L/H 204.25 322.5 451.5 645 903 1290 1935 2580 3096
Power supply 3N 380V/50Hz
Compressor Type Fully closed scroll type
Start mode Directly start
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow M3/h 2.1  3.3  4.6  6.0  8.9  12.9  18.0  24.9  29.9 
Water pressure drop KPa 50 55 55 60 60 65 65 65 ≤65
Pipe size DN 25 25 25 32 32 50 65 65 80
Middle heat exchanger Type Brazed plate type heat exchanger
Protections 1. High pressure and low pressure protection,
2. Anti-freezing protection,
3. High temperature protection,
4. Too big of the water temperature difference for outlet and inlet protection,
5. Overload protection,
6. Lack phase protection,
7. Reverse phase protection, etc.. 
Noise DB(A) 55 58 58 60 ≤60 ≤65 73 74 ≤78
Unit dimensions mm 835×410×1330 820*695*1060 1000×1000×1858 1000×2050×1900 2000×2050×1980
Package dimensions mm 910*480*1370 850*950*1300 1150*1150*2250 1150×2200x2300 2300×2100×2300
Weight KG 115 175 245 355 425 620 855 1250 1300
Testing condition: 1. Normal condition: dry bulb 20ºC, wet bulb 15ºC; initial water temperature 15ºC, end water temperature 55ºC.
                          2. Nominal condition: dry bulb 7ºC, wet bulb 6ºC; initial water temperature 9ºC, end water temperature 55ºC.
                          3. Low temperature condition: dry bulb -12ºC, wet bulb -14ºC; initial water temperature 9ºC, end water temperature 55ºC.

 