Air to Water High Temp Heat Pump Water Heater Large Heating Capacity

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 80-90°C
Still deciding? Get samples of US$ 1500/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
  • Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
  • Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
  • Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
  • Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
Find Similar Products

Basic Info.

Model NO.
HT03P-E3 ---HT60P-C96
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB, RoHS, SASO
Product Name
Commercial Use Air Source Heat Pump (Ckfxrs-70II)
Rated Heating Capacity
8kw~210kw
Suitable Environment
-7~43
Color
White Colored
Controller
Konnen Brand
Testing
25HP National Proved Laboratory
Rated Power Input
2.4--46
Cop
3.4
Transport Package
Safety Export Packing, with Pallet
Specification
Standard
Trademark
KONNEN
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
500 Units/Month

Product Description

WE SUPPLY OEM SERVICE!


Features:
Split-type design and independent water tanks for flexible and convenient connection of water pipes.
Flexible installation of main unit and water tank.
Dynamic heat exchange between water and coolant as there is no coolant pipe in the water tank. This will reduce the damping of the heat exchanger and thus ensure adequate flow of water, prevent leakage caused by corrosion of copper tube, and reduce scale formation in the system.
Free selection of water tank sizes.
Stainless steel water tank with good insulation and less scale formation to ensure the quality of water.
Isolated water and electricity system to ensure operating safety.
Constant Outlet Water Temperature

Water temperature can be set between 40 degrees and 60 degrees, with an difference of less than 1degrees. The outlet temperature can be easily controlled and the adjustment will cause no significant change in water temperature. Whether the outlet quantity is increased or decreased, the water temperature will remain unchanged.

The RL series can produce constant temperature water no matter how the flow is adjusted. In the case of common gas water heaters, the water temperature will change when the flow is adjusted. The temperature will go down when the outlet flow is decreased; Otherwise, it will go up. A sudden rise in water temperature may cause skin burns. When the water flow is too small, the heater may be choked off. For those with a complicated pipe system, the water temperature will be more difficult to control.


KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
WHY US:
Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
KONNEN NEW PROJECTS:
Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
KONNEN HEAT PUMPS LOADING:
Air to Water High Temp Heat Pump Water Heater Large Heating Capacity
PARAMETERS TABLE:
Volcano series (High temperature air source heat pump water heater circulation type)
  HT3Ps-E3 HT5sP-E5 HT3P-E3 HT5P-E5 HT7P-E7 HT10P-E10 HT14P-E14 HT20P-E20 HT24P-E20 HT30P-E20 HT40P-C96 HT48P-C96 HT60P-C96
Rated heating capacity kW 8.2 13.5 8.2 13.5 17.8 26.1 34.7 55.2 64.3 78.5 108.8 129.5 153.7
Rated input power kW 2.42 3.98 2.42 3.95 5.26 7.65 10.21 16.32 19.13 23.56 31.91 38.09 45.88
Rated input current A 10.58 17.56 4.58 7.52 9.99 14.55 19.35 30.95 36.33 44.71 60.60 72.34 87.14
Maximum input power kW 3.14 5.17 3.14 5.13 6.84 9.95 13.27 21.22 24.88 30.63 39.88 47.62 57.36
Maximum input current A 14.01 23.23 5.95 9.75 13.02 19.13 24.98 40.25 46.88 57.96 75.75 90.44 108.94
Performance coefficient(COP) / 3.39 3.39 3.39 3.42 3.38 3.41 3.40 3.38 3.36 3.33 3.41 3.40 3.35
Rated hot water output temp. ºC 75
Maximum hot water output temp. ºC 80
Rated hot water produce capacity t40 L/H 175.7 289.3 175.7 289.3 381.4 559.3 743.6 1182.9 1377.9 1682.1 2042.5 2795.0 3440.0
t60 L/H 117.1 192.9 117.1 192.9 254.3 372.9 495.7 788.6 918.6 1121.4 1559.0 1863.3 2293.4
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Hermetic scroll type
Start Mode Directly start(Soft start for option)
Quantity Set 1 1 1 1 1 2 2 4 4 4 4 4 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 1.4 2.3 1.4 2.3 3.1 4.5 6.0 9.5 11.2 13.8 18.7 22.4 27.6
Water Pressure Drop kPa ≤45 ≤53 <50 <55 <57 <60 <70 <70 <72 <72 <75 <75 <75
Pipe size mm DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN80 DN80 DN80
Protections 1. High pressure and low pressure protection,
2. Anti-freezing protection,
3. High temperature protection,
4. Too big of the water temperature difference for outlet and inlet protection,
5. Overload protection,
6. Lack phase protection,
7. Reverse phase protection, etc..
Refrigerant Type R134a
Throttle Type Electronic expansion valve
Quantity kg 1.9 3.3 1.9 3.3 4.3 2.8×2 4.1×2 3.2×4 3.8×4 4.6x4 6.4×4 7.6×4 9.2x4
Noise DB(A) ≤55 ≤63 ≤55 ≤63 ≤65 ≤68 ≤68 ≤70 ≤70 ≤72 ≤74 ≤74 ≤75
Dimension mm 700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1360
1502×750×
1060
1502×750×
1360
1995×1165
×1105
1995×1165
×1105
1995×1165
×1105
2000×2050
×1980
2000×2050
×1980
2000×2050
×1980
Net Weight kg 110 160 110 160 190 255 410 600 755 855 1050 1250 1620
Testing conditions:
1. Application side initial water temperature: 15ºC, end temperature 75ºC, max. temperature 80ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC.
The above parameters are based on Refrigearnt R134a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any  business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier