7 Years Heat Pump Factory for Evi Air Source Heat Pump

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 40-60°c
Still deciding? Get samples of US$ 1400/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • 7 Years Heat Pump Factory for Evi Air Source Heat Pump
  • 7 Years Heat Pump Factory for Evi Air Source Heat Pump
  • 7 Years Heat Pump Factory for Evi Air Source Heat Pump
  • 7 Years Heat Pump Factory for Evi Air Source Heat Pump
Find Similar Products

Basic Info.

Model NO.
EVI05P
Work Environment
Low-temperature Heat Pump
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, SASO, TUV
Rated Heating Capacity
12kw, 19kw, 35kw
Compressor
Copeland
Type
Side Blowing
Cop at Ambient Temp. -25c
2.0
Transport Package
Safe Export Packing, with Pallet
Specification
CE
Trademark
KONNEN
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
2000 Units/Month

Product Description

KONNEN AIR SOURCE HEAT PUMP, EVI AIR TO WATER HEAT PUMP ,WORKING TEMPERATURE -30° C--43° C.
* Low-temperature cycle type with great performance of environmental protection, low operating costs, outstanding energy savings, safety and so on.
* Improving performance under cold temperature, safe and reliable - air injection & increase enthalpy products to achieve heating operation whthin-25 ° C - 43 ° C, increaseing the compressor heating capacity in the cold, rising nearly 20% heating capacity under-10 ° C, leading to "strong hot and cold" era. When the temperature is as low as -20 ° C the heat pump can start running and get good effect of hot water supply.

Scope: Hotels, guesthouses, entertainment sauna center, body building club, beauty salon, bathing centers, hospitals, factories, restaurants, dormitories, residential central heating and other hot water useing places.

1, High efficiency
* Energy efficient - the unit uses the world advanced technology - air injection & increase enthalpy systems, high efficiency heat exchanger technology, technology, air injection and enthalpy increase, higher COP in low temperature.

2, Safe and reliable
* Safe and reliable -useing of microcomputer for automatic control, control and fill constant temperature of hot water and ensure water temperature in water tank according to the water level, temperature, which can meet the requirement for all day water using in any time, water and electricity are separated, safe and reliable.
* Microcomputer controlled power-off memory, automatic fault detection, protection timely, more reliable, use more confidence.
* Easy installation - remote controller installation, strong and weak electric be completely separated, operation securely.

3, Energy saving
* Use R417A, R407C refrigerant, ozone depletion factor is zero, green, to meet the national environmental requirements, to eliminate the forbidden risk. (Optional refrigerant R22)
WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
7 Years Heat Pump Factory for Evi Air Source Heat Pump
WHY US:
7 Years Heat Pump Factory for Evi Air Source Heat Pump
KONNEN NEW PROJECTS:
7 Years Heat Pump Factory for Evi Air Source Heat Pump
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
7 Years Heat Pump Factory for Evi Air Source Heat Pump
KONNEN HEAT PUMPS LOADING:
7 Years Heat Pump Factory for Evi Air Source Heat Pump
PARAMETERS TABLE:
A02U series( EVI air source heat pump low temperature type)                                                                                                                          EVI-150307  
  EVI3P-S5 EVI5P-S5 EVI10P-C24 EVI14P-C24 EVI20P-C48 EVI30P-C48 EVI40P-C96 EVI48P-C96
Normal condition Heating capacity kW 12 19 36 51 75 105 145 165
Input power kW 2.80  4.40  8.20  11.85  17.10  24.10  33.20  38.10 
Input current A 5.30  8.60  14.80  22.58  33.00  45.10  62.50  72.30 
COP / 4.29  4.32  4.39  4.24  4.39  4.36  4.37  4.33 
Nominal  condition Rated heating capacity kW 9.50  15.00  30.00  42.00  60.00  90.00  120.00  144.00 
Rated input power kW 2.60  4.10  8.10  11.34  16.10  24.50  32.50  39.30 
Rated input current A 5.20  8.20  15.30  21.42  30.20  46.00  61.10  73.60 
COP / 3.65  3.66  3.70  3.70  3.73  3.67  3.69  3.66 
Low temperature condition Heating capacity kW 5.50  8.80  17.50  24.50  36.50  52.50  70.00  84.00 
Input power kW 2.26  3.65  7.30  10.22  15.10  21.60  29.10  34.90 
Input current A 4.29  6.93  13.00  18.20  28.10  40.80  54.80  65.70 
COP / 2.43  2.41  2.40  2.40  2.42  2.43  2.41  2.41 
Maximum input power/current kW/A 3.61/6.92 5.71/11.20 10.62/20.75 15.42/30.08 22.27/43.36 31.38/612 42.92/83.62 51.5/100.3
Rated hot water output temperature ºC 55
Maximum hot water output temperature ºC 60
Rated hot water produce capacity L/H 204.25 322.5 645 903 1290 1935 2580 3096
Power supply 3N 380V/50Hz
Compressor Type Fully closed scroll type
Start mode Directly start
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow M3/h 2.1  3.3  6.0  8.9  12.9  18.0  24.9  29.9 
Water pressure drop KPa ≤50 ≤55 ≤60 ≤60 ≤65 ≤65 ≤65 ≤65
Pipe size DN 25 25 32 32 50 65 65 80
Middle heat exchanger Type Brazed plate type heat exchanger
Protections 1. High pressure and low pressure protection,  2. Anti-freezing protection, 
3. High temperature protection, 4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection,  6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Noise DB(A) ≤55 ≤58 ≤60 ≤60 ≤65 ≤73 ≤74 ≤78
Unit dimensions mm 835×410×1330 1000×1000×1858 1000×2050×1900 2000×2050×1980
Package dimensions mm 910*480*1370 1150*1150*2250 2200×1150×2300 2300×2100×2300
Weight KG 115 175 355 425 620 855 1250 1300
Testing condition: 1. Normal condition: dry bulb 20ºC, wet bulb 15ºC; initial water temperature 15ºC, end water temperature 55ºC.
                          2. Nominal condition: dry bulb 7ºC, wet bulb 6ºC; initial water temperature 9ºC, end water temperature 55ºC.
                          3. Low temperature condition: dry bulb -12ºC, wet bulb -14ºC; initial water temperature 9ºC, end water temperature 55ºC.
 
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier