• Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
  • Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
  • Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
  • Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
  • Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
  • Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality

Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality

Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Heat Source: Air-source
Application: Sauna and Swimming Pool
Certification: CE, ISO9001
Usage: Swimming Pool
Samples:
US$ 598/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
S02H
Heating Capacity
120kw
Product Name
Swimming Pool Heat Pump (Ckfcrs-120II)
Refrigerant
R410A
Compressor
SANYO
Transport Package
Safety Export Packaging Plus Plywood
Specification
CE
Trademark
CEN (Creative Power)
Origin
Zhejiang, China( Main Land)
HS Code
8418612090
Production Capacity
500units /Month

Product Description

  KONNEN SWIMMING POOL HEAT PUMP WATER HEATER:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R410a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "Gimleo" Titanium tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* Schneider AC contactor and relay;
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

We also supply OEM services!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):

Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
WHY US:
Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
WORLD FAMOUS BRAND WE COOPERATED FOR OUR HEAT PUMPS:
Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
KONNEN NEW PROJECTS:
Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
KONNEN HEAT PUMP LOADING:
Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality
Product features:
Swimming Pool Heat Pum for Heating and Cooling Wuith High Quality

Parameters table:

S02H series(Swimming pool heat pump)                                                                                                                                                                                                        
  SP2.5PS-H2 SP03PS-E3 SP05PS-E5 SP03P-E3 SP05P-E5 SP07P-E5 SP10P-C24 SP14P-C24 SP20P-C48 SP24P-C48 SP30P-C48 SP36P-C96 SP40P-C96 SP48P-C96
Rated heating capacity kW 12  14  24  14  24  32  48  66  95  115  145  170  190  230 
Rated input power kW 2.11  2.45  4.14  2.37  4.06  5.69  8.14  11.57  16.10  19.49  25.11  29.31  32.76  39.65 
Rated input current A 10.82  12.56  21.23  4.55  7.80  10.92  15.63  22.21  30.91  37.42  48.21  56.28  62.90  76.13 
COP  / 5.59  5.71  5.80  5.91  5.91  5.62  5.90  5.70  5.90  5.90  5.77  5.80  5.80  5.80 
*Heating capacity kW 12  20  12  20  25  40  52  80  95  120  145  160  190 
*Input power kW 1.80  2.30  3.88  2.33  3.80  4.87  7.62  9.98  15.36  18.20  22.81  27.83  30.48  36.19 
*Input current A 9.21  11.81  19.92  4.47  7.30  9.36  14.63  19.16  29.48  34.94  43.80  53.44  58.51  69.49 
*COP / 5.01  5.21  5.15  5.15  5.26  5.13  5.25  5.21  5.21  5.22  5.26  5.21  5.25  5.25 
Maximum input power kW 2.74  3.19  5.38  3.08  5.28  7.40  10.58  15.04  20.93  25.34  32.64  38.10  42.59  51.55 
Maxmum input current A 14.05  16.33  27.60  5.92  10.13  14.20  20.32  28.88  40.19  48.65  62.67  73.16  81.77  98.97 
Rated hot water output temperature' ºC 28 
Maximum hot water output temperature ºC 35 
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Rotor type Fully closed scroll type
Start mode Directly start
Quantity Set 1 1 1 1 1 1 2 2 2 2 3 3 4 4
Water side heat exchanger Type Titanium tube heat exchanger
Water flow M3/h 5.07  6.02  10.32  6.02  10.32  13.76  20.64 28.38 40.85 49.45  62.35  73.10  81.70  98.90 
 Water pressure drop KPa ≤50 ≤70
Pipe size Φ Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ90 Φ90 Φ110 Φ110 Φ110
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection,
8. Water flow protection etc.
Noise DB(A) ≤50 ≤55 ≤63 ≤55 ≤63 ≤63 ≤65 ≤68 ≤70 ≤72 ≤73 ≤74 ≤76 ≤78
Unit dimensions mm 1000×360×
630
700×700×
870
820×695×
1060
700×700×
870
820×695×
1060
820×695×
1060
1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1980 2000×2050×1980 2000×2050×1980 2000×2050×1980
Weight KG 64 100 160 100 160 165 335 365 600 660 840 860 1225 1260
Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC
                             2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC
The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us.