• High Temperature Air Source Heat Pump Water Heater for Hotel
  • High Temperature Air Source Heat Pump Water Heater for Hotel
  • High Temperature Air Source Heat Pump Water Heater for Hotel
  • High Temperature Air Source Heat Pump Water Heater for Hotel
  • High Temperature Air Source Heat Pump Water Heater for Hotel
  • High Temperature Air Source Heat Pump Water Heater for Hotel

High Temperature Air Source Heat Pump Water Heater for Hotel

Energy Efficiency Grade: One
Heat Temperature: 60-80°c
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HT3P--HT48P (8kw-160kw)
Certification
CE, ISO9001, CCC, SASO, TUV
Product Name
Air Source Commercial Use Heat Pump (Kfxrs)
Compressor
Copeland or Panasonic
Refrigerant
R134A
Heating Capacity
8~160kw
Rated Produce Hot Water Capacity
115-2325L/H
Rated Input Power(Kw)
2.19~44.5kw
Power Supply
3n 380V/50Hz
Rated Hot Water Output Temp.
75 Celsius Degree
Max. Hot Water Output Temp.
80 Celsius Degree
Cop
3.65
Transport Package
Safety Export Packing
Specification
standard
Trademark
KONNEN
Origin
Zhejiang, China( Main Land)
HS Code
8418612090
Production Capacity
1800 PCS Per Month

Product Description


KONNEN HIGH TEMPERATURE AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor OR Copeland compressor with R134a refrigerant,
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
High Temperature Air Source Heat Pump Water Heater for Hotel
WHY US:
High Temperature Air Source Heat Pump Water Heater for Hotel
KONNEN NEW PROJECTS:
High Temperature Air Source Heat Pump Water Heater for Hotel
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
High Temperature Air Source Heat Pump Water Heater for Hotel
KONNEN HEAT PUMPS LOADING:
High Temperature Air Source Heat Pump Water Heater for Hotel
PARAMETERS TABLE:
A03H (High temperature air source heat pump water heater circulation type)                                                                                                                HT-150307
  HT3P-T3 HT5P-T5 HT7P-T5 HT10P-C24 HT14P-C24 HT20P-C48 HT24P-C48 HT30P-C48 HT48P-C96
Rated heating capacity kW 8 13.5 18 26 35 55 65 80 130
Rated input power kW 2.19  3.66  4.96  7.11  9.62  14.91  17.81  21.98  35.81 
Rated input current A 4.14  6.92  9.37  13.55  18.17  28.17  33.66  41.54  67.69 
Maximum input power kW 2.74  4.58  6.20  8.89  12.02  18.63  22.26  27.47  44.77 
Maximum input current A 5.34  8.92  12.09  17.33  23.44  36.33  43.41  53.57  87.29 
Performance coefficient(COP) / 3.65  3.69  3.63  3.65  3.64  3.69  3.65  3.64  3.63 
Rated hot water output temp. ºC 75
Maximum hot water output temp. ºC 80
Rated hot water produce capacity △t40 L/H 172.0  290.3  387.0  559.0  752.5  1182.5  1397.5  1720.0  2795.0 
△t60 L/H 114.7  193.5  258.0  372.7  501.7  788.3  931.7  1146.7  1863.3 
Power supply 3N 380V/50Hz
Compressor Type Fully closed scroll type
Start Mode Directly start
Quantity Set 1 1 1 2 2 4 2 3 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 1.4  2.3  3.1  4.5  6.0  9.5  11.2  13.8  22.4 
Water Pressure Drop kPa <50 <55 <57 <60 <60 <65 <65 <65 <65
Pipe size mm DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN80
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Refrigerant Type R134a
Throttle Type Electronic expansion valve
Quantity kg 2.1 3.3 4.3 2.8×2 4.1×3 3.2×4 7.6×2 6.2*3 7.6×4
Noise DB(A) 55 63 65 65 68 70 72 73 78
Unit Dimension  mm 700×680×
875
860×820×
1080
860×820×
1080
1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1900 2000×2050×1900
Package Dimension mm 788x768x940 898x898x1140 898x898x1140 1100x1100x1880 1100x1100x1880 1080x2130x 1940 1080x2130x 1940 1080x2130x 1940 2028x2220×1940
Net Weight kg 100 170 190 310 410 605 650 835 1250
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 75ºC, max. temperature 80ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC
The above parameters are based on Refrigearnt R134a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any  business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now