Air Source Heat Pump for Cooling, Heating&Hot Water 70kw

Product Details
Customization: Available
Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Still deciding? Get samples of US$ 1380/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
  • Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
  • Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
  • Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
  • Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
Find Similar Products

Basic Info.

Model NO.
AM03P-AM48P (8KW-132KW)
Heat Source
Air-source
Application
Villa Family
Certification
CE, ISO9001, CCC
Name
Air Source Heat Pump Cchh
Compressor
SANYO
Refrigerant
R410A
Color
Gray or White
Cooling Capacity
9kw~80kw
Heating Capacity
10kw~81kw
Water Heating Capacity
12kw~85kw
Transport Package
Safe Packing
Specification
Yes
Trademark
CEN
Origin
China
HS Code
8418612090
Production Capacity
5000 Units/Month

Product Description

KONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
WHY US:
Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
KONNEN NEW PROJECTS:
Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
KONNEN HEAT PUMPS LOADING:
Air Source Heat Pump for Cooling, Heating&Hot Water 70kw
PARAMETERS TABLE:
C02F series (air source cooling/heating module heat pump)                                                                                                                                 AM-160119
  AM03Ps-S5 AM04.6Ps-S5 AM05P-S5 AM06P-S5 AM07P-T5 AM10P-C24 AM12P-C24 AM14P-C24 AM24P-C48 AM36P-C48 AM48P-C48
Rated cooling capacity kW 12.5  13  15  18  26  30  38  66  99  132 
Rated heating capacity kW 8.8  13.5  14.5  16.5  19.5  28  31  41  71  107  136 
Rated input power for cooling kW 2.48  3.88  4.08  4.72  5.59  8.20  9.50  11.80  21.60  31.20  41.30 
Rated input power for heating kW 2.70  4.14  4.50  5.14  5.58  8.51  9.50  12.40  21.90  33.10  41.90 
Rated input current for cooling A 12.12  18.94  7.72  8.96  10.66  15.58  17.90  22.90  40.70  58.60  77.80 
Rated input current for heating A 12.85  19.72  8.52  9.77  10.49  16.17  18.10  23.50  41.50  62.50  79.40 
Maximum input power kW 3.24  4.97  5.40  6.17  6.91  10.21  11.60  14.80  26.70  40.30  51.20 
Maximum input current A 15.50  23.78  10.00  12.03  13.20  19.91  21.70  28.40  49.80  75.10  95.40 
Cooling performance coefficient (EER)  / 3.22  3.22  3.19  3.18  3.22  3.17  3.16  3.22  3.06  3.17  3.20 
Heating performance coefficient (COP) / 3.26  3.26  3.22  3.21  3.26  3.29  3.26  3.31  3.24  3.23  3.25 
Energy regulation % 0, 100 0, 50, 100 0,33,66,100 0,25,50,100
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Fully closed scroll type
Start mode Directly start 
Quantity Set 1 1 1 1 1 2 2 2 2 3 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow M3/h 1.38  2.15  2.24  2.58  3.09  4.47  5.16  6.54  11.35  17.03  22.70 
Water pressure drop KPa 40 40 40 40 40 40 40 40 50 50 50
Water pipe size DN DN25 DN32 DN65
 Pipe connection Inner thread Flange
Fan Type Efficient axial type
Wind blowing type Side blowing Top blowing 
Refrigerant Throttle type Electronic expansion valve
Quantity KG 2.1 3.1 3.3 3.6 4.3 3.3×2 3.6×2 4.2×2 9.5×2 9.5×3 9.5×4
Unit dimensions Length MM 835 835 835 835 860 1000 1000 1000 2050 2050 2050
Width MM 410 410 410 410 820 1000 1000 1000 1000 1000 1000
Height MM 1330 1330 1330 1330 1080 1858 1858 1858 1900 1980 1980
Noise DB(A) 50 62 63 63 ≤63 65 65 68 ≤72 73 74
Weight KG 115 135 170 185 190 310 335 360 650 820 940
Testing condition:1. Standard cooling working condition: dry bulb temperature 35ºC, water input 12ºC, water output 7ºC.
                         2. Standard heating working condition: dry bulb temperature 7ºC, wet bulb 6ºC; water input 40ºC, water output 45ºC.
The above parameter are for single module,could be grouped according to requirements. 
The above parameters are based on Refrigearnt R410A,for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating,so above information is not the provision of any business contract.Please refer to final product label when buy,or refer to us for any information.Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier