Water/Ground Source Heat Pump for Cooling&Heating

Product Details
Customization: Available
Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
Find Similar Products

Basic Info.

Model NO.
CRS
Heat Source
Water-source
Application
Villa Family
Certification
CE, ISO9001, CCC
Product Name
Water/Ground Source Heat Pump for Cooling&Heating
Refrigerant
R410A
Rated Heating Capacity
4.3~91kw
Cooling Capacity
4~80kw
Compressor
SANYO or Panasonic
Transport Package
Carton Packaging with Plywood
Specification
CE
Trademark
CEN
Origin
China
Production Capacity
3000units/Month

Product Description

Water/Ground Source Heat Pump for Cooling&HeatingWater/Ground Source Heat Pump for Cooling&HeatingWater/Ground Source Heat Pump for Cooling&HeatingMulti function air to water heat pump
Heating/cooling system and hot water
Central air conditioner
High COP heat pump
Low noise
Air source heat pump
Air to water heat pump

Air to water Multi-functional Heat pump

* Heat Pump(Multi-use): Room Heating, Air Conditioning and Domstic Hot Water

Air to water Multi-functional House Heat Pump can satisfy all your needs at your home. You not only can get the room heating in winter and have the air conditioning in summer, but also enjoy the hot water for bath and domstic use

* Saving: Reducing heating costs up to 65%

Alto Air to water Multi-functional House Heat Pump will dramatically reduce heating costs up to 65%. It only needs a bit of electrical energy to start extracting the heat energy from the air, which requires only 1 kilowatt of electricity to transfer 3 to 5 kilowatt of heat into your home. That means:
2/3 free energy from air + 1/3 electrical energy = Warm and Safe Water

* Environment: Less CO2 emission for better environment

Alto Air to water Multi-functional House Heat Pump does not use any combustion process or energy to generate heat. It only uses little electricity to transfer the energy from air to water
water(ground) source heat pump cooling & heating
Modle   CRS-4I   CRS-8I CRS-12II CRS-20II CRS-40II   CRS-70II CRS-80II CRS-120II CRS-165II CRS-200II CRS-240II CRS-300II
Cooling capacity kW 4 8 12 20 40 60 80 120 165 200 240 300
Heating capacity kW 4.3 8.6 13 22 45 69 91 131 176 213 260 315
Cooling input power kW 0.8 1.6 2.5 4.1 8.3 12.7 16.6 25.3 32.3 39.2 47 58.8
heating input power kW 0.95 1.9 2.8 4.7 10.4 14.6 20.6 27.2 39.1 47.3 57.7 70
Cooling input current A 4.3 8.4 4.5 7.5 15 22.7 29.5 45.5 58 71 85 106
Heating input current A 5.1 10.1 5.2 8.5 18.6 27 37 50.3 71 86 106 127
Underground working condution Cooling capacity kW 3.9 7.7 11.5 19.5 38.4 57.6 76.9 115.3 158.6 192.3 230.7 288.4
Heating capacity kW 4.2 8.2 12.5 21.2 43.2 66.3 85.1 125.9 169.2 204.8 250 302.8
Cooling input power kW 0.81 1.6 2.4 4.1 8.2 12.4 16.7 24.9 32.3 39.2 47 58
Heating input power kW 0.93 1.8 2.7 4.8 10 15.4 20.3 29.2 41.2 49.9 60.9 73.8
Cooling input current A 4.2 8.5 4.5 7.5 15 23.5 31.5 46 60.2 72.9 86 105
Heating input current A 4.8 9.8 5.3 9.1 18 29.1 37.5 55.3 76.6 92.8 113.2 137
Underground circle type nominal working condition Cooling capacity kW 3.8 7.6 11.4 19.1 38 57 76.2 114.1 157 190.3 228.4 285.5
Heating capacity kW 4.1 8.1 12.3 20.9 42 65 80.1 124.6 167.5 202.3 247.5 299.8
Cooling input power kW 0.8 1.6 2.4 4.2 8.4 12.7 16.9 25.3 32.9 39.8 47.8 59.8
Heating input power kW 1.1 2.1 3.1 5.1 10.5 16.2 20 31.1 41.8 50.5 61.8 74
Cooling input current A 4.2 8.4 4.7 7.9 15.6 23.6 31.9 47 61.1 74 88 111
Heating input current A 5.7 11.1 5.8 9.6 18 30.1 37.8 57.8 77.7 93 114 139.3
Circle water working conditon Cooling capacity kW 3.6 7.2 10.9 18.1 36.2 54.3 72.4 108.7 149.5 181.3 217.5 271.9
Heating capacity kW 4.7 10.3 15.6 26.4 54.6 84.5 104 161.9 218 266 330 390
Cooling input power kW 0.95 1.9 2.9 4.8 9.5 14.2 19.1 28.6 36.4 44.2 53 66.3
Heating input power kW 1.04 2.3 3.4 6 12.1 18.7 23.1 35.9 43.6 53.2 66 78
Cooling input current A 5.1 10.3 5.6 9.3 17.6 26.4 36 53.1 67.7 82 98 123.3
Heating input current A 5.5 12.3 6.7 11.4 22.5 34.7 43 66.7 81 98 122.7 145
power 220V/50Hz 380V/50Hz
Compressor type Rotor Scroll Double-Screw-Refrigeration Compressors
NO. UNIT 1 1 1 1 1 2 2 2 1 1 1 1
Energy regulation % 0, 100 0, 100 0, 100 0, 100 0, 100 0, 50, 100 0, 50, 100 0, 50, 100 0, 25, 50, 75, 100
Heating source side heat exchanger  Type Plate type heat exchanger
  Horizontal type shell& tube heat exchanger
Underground water make cooling water flow m 3 /h 0.36 0.7 1 1.7 3.4 5.2 6.7 10.8 14.2 16 20 24
Underground water make heating  water flow m 3 /h 0.42 0.83 1.3 2.1 4.2 6.2 8.3 12.4 17 21 25 31
Underground circle type nominal working condition cooling water flow m 3 /h 0.7 1.4 2.2 3.6 7.2 11.2 13.7 21.4 28.8 35 42 52
Underground circle type nominal working condition heating water flow m 3 /h 0.65 1.3 1.96 3.3 6.5 9.8 13.1 19.6 27 33 39.5 49
Water tube interface mm DN20 DN20 DN20 DN25 DN40 DN50 DN80 DN100
User side heat exchanger Type Plate type heat exchanger   Horizontal type shell& tube heat exchanger
cooling water flow m3/h 0.7 1.4 2.1 3.4 6.8 10.3 13.7 20 28.3 34.4 41.3 52
Heating water flow m3/h 0.74 1.5 2.2 3.8 7.7 11.8 15.6 22.5 30 36.6 44.7 54.2
Water tube interface mm DN20 DN20 DN20 DN25 DN40 DN50 DN80 DN100
Protector 1\High and low pressure protection, 2\anti-freeze protection, 3\temperature protection, 4\safety valve, 5\overload protection, 6\Reverse phase,
7\Lack of phase, 8\Separation of water and electricity, ect.
Refrigerant Type R410a/R407c
Throttle Mode thermostatic expansion valve
weight kg 0.8 1.2 1.9 3 12 19 23 39 45 56 67 82
Size Long mm 709 709 709 810 1760 2400 2400 2560 2560 2650 2890 2890
Wide mm 359 359 359 420 500 650 650 880 900 900 900 1100
High mm 592 592 592 590 1150 1210 1260 1300 1335 1430 1430 1530
Noise ≤ dB(A) 35 35 38 42 55 60 60 62 65 66 66 68
Weight kg 43.8 45 69 93 340 570 612 850 1150 1300 1450 1850
Note: 1, Underground circle type nominal cooling working condition: User side water inlet/outlet temperature 12º C/7º C; Source side water inlet/outlet temperature 25º C/30º C













              Underground circle type nominal Heating working condition: User side water inlet/outlet temperature 40º C/45º C; Source side water inlet/outlet temperature 10º C/5º C













        2, Underground water type nominal cooling workingcondition: user side water inlet/outlet temperature 12º C/7º C; source side water inlet/outlet temperature 18º C/29º C













              Underground water type nominal heating workingcondition: user side water inlet/outlet temperature 40º C/45º C; source side water inlet/outlet temperature 15º C/7º C













        3, Circle water type nominal cooling workingcondition: user side water inlet/outlet temperature 12º C/7º C; source side water inlet/outlet temperature 30º C/35º C













              Circle water type nominal heatinging workingcondition: user side water inlet/outlet temperature 40º C/45º C; source side water inlet/outlet temperature 20º C/15º C













        4, Standard cooling working condition: User side water inlet/outlet temperature 12º C/7º C; Source side water inlet/outlet temperature 15º C/20º C













            Standard heating working condition: User side water inlet/outlet temperature 40º C/45º C; Source side water inlet/outlet temperature 15º C/10º C













      5, The above parameters based on Refrigearnt R22, for parameters based on other refrigerants please contact us.













      6, The product parameters may have some difference from the final product because of products updating, please refer to final product label when buy. Our company keeps the right to interpret.














Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier