Certification: SASO, CCC, ISO9001, CE
Working Medium: 134A
Heat Source Type: Air Source Heat Pump
Product Name: Commercial Use Air Source Heat Pump (Ckfyrs-35II)
Rated Outlet Hot Water Temperature: 75 Degree
Maximum Outlet Hot Water Temperature: 80 Degree
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HT30P-E20
Compressor
Panasonic / Copeland
Refrigerant
R134A
Rated Heating Capacity
78.5kw
Rated Input Power
23.56kw
Rated Input Current
44.71A
Transport Package
Safe Export Packing
Specification
HT30P-E20
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
3, 000PCS/Month

Product Description

KONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic / Copeland compressor & R134a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Good quality shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
High Temperature Air Source Heat Pump Commercial Use Heat Pump Water Heater 75c
WHY US:
High Temperature Air Source Heat Pump Commercial Use Heat Pump Water Heater 75c
KONNEN NEW PROJECTS:
High Temperature Air Source Heat Pump Commercial Use Heat Pump Water Heater 75c
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
High Temperature Air Source Heat Pump Commercial Use Heat Pump Water Heater 75c
KONNEN HEAT PUMPS LOADING:
High Temperature Air Source Heat Pump Commercial Use Heat Pump Water Heater 75c
PARAMETERS TABLE:
Volcano series (High temperature air source heat pump water heater circulation type)
  HT3Ps-E3 HT5sP-E5 HT3P-E3 HT5P-E5 HT7P-E7 HT10P-E10 HT14P-E14 HT20P-E20 HT24P-E20 HT30P-E20 HT40P-C96 HT48P-C96 HT60P-C96
Rated heating capacity kW 8.2 13.5 8.2 13.5 17.8 26.1 34.7 55.2 64.3 78.5 108.8 129.5 153.7
Rated input power kW 2.42 3.98 2.42 3.95 5.26 7.65 10.21 16.32 19.13 23.56 31.91 38.09 45.88
Rated input current A 10.58 17.56 4.58 7.52 9.99 14.55 19.35 30.95 36.33 44.71 60.60 72.34 87.14
Maximum input power kW 3.14 5.17 3.14 5.13 6.84 9.95 13.27 21.22 24.88 30.63 39.88 47.62 57.36
Maximum input current A 14.01 23.23 5.95 9.75 13.02 19.13 24.98 40.25 46.88 57.96 75.75 90.44 108.94
Performance coefficient(COP) / 3.39 3.39 3.39 3.42 3.38 3.41 3.40 3.38 3.36 3.33 3.41 3.40 3.35
Rated hot water output temp. ºC 75
Maximum hot water output temp. ºC 80
Rated hot water produce capacity △t40 L/H 175.7 289.3 175.7 289.3 381.4 559.3 743.6 1182.9 1377.9 1682.1 2042.5 2795.0 3440.0
△t60 L/H 117.1 192.9 117.1 192.9 254.3 372.9 495.7 788.6 918.6 1121.4 1559.0 1863.3 2293.4
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Hermetic scroll type
Start Mode Directly start(Soft start for option)
Quantity Set 1 1 1 1 1 2 2 4 4 4 4 4 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 1.4 2.3 1.4 2.3 3.1 4.5 6.0 9.5 11.2 13.8 18.7 22.4 27.6
Water Pressure Drop kPa ≤45 ≤53 <50 <55 <57 <60 <70 <70 <72 <72 <75 <75 <75
Pipe size mm DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN80 DN80 DN80
Protections 1. High pressure and low pressure protection,
2. Anti-freezing protection,
3. High temperature protection,
4. Too big of the water temperature difference for outlet and inlet protection,
5. Overload protection,
6. Lack phase protection,
7. Reverse phase protection, etc..
Refrigerant Type R134a
Throttle Type Electronic expansion valve
Quantity kg 1.9 3.3 1.9 3.3 4.3 2.8×2 4.1×2 3.2×4 3.8×4 4.6x4 6.4×4 7.6×4 9.2x4
Noise DB(A) ≤55 ≤63 ≤55 ≤63 ≤65 ≤68 ≤68 ≤70 ≤70 ≤72 ≤74 ≤74 ≤75
Dimension mm 700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1360
1502×750×
1060
1502×750×
1360
1995×1165
×1105
1995×1165
×1105
1995×1165
×1105
2000×2050
×1980
2000×2050
×1980
2000×2050
×1980
Net Weight kg 110 160 110 160 190 255 410 600 755 855 1050 1250 1620
Testing conditions:
1. Application side initial water temperature: 15ºC, end temperature 75ºC, max. temperature 80ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC.
The above parameters are based on Refrigearnt R134a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any  business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now