• Air to Water Swimming Pool Heat Pump (S02H Series)
  • Air to Water Swimming Pool Heat Pump (S02H Series)
  • Air to Water Swimming Pool Heat Pump (S02H Series)
  • Air to Water Swimming Pool Heat Pump (S02H Series)
  • Air to Water Swimming Pool Heat Pump (S02H Series)

Air to Water Swimming Pool Heat Pump (S02H Series)

Energy Efficiency Grade: One
Heat Temperature: 28-35c
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels
Samples:
US$ 1100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SP03P-SP48P (14KW-230KW)
Certification
CE, ISO9001, CCC
Transport Package
Plywood Case
Specification
SP03P- SP48P
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
2500PCS/Month

Product Description

KONNEN SWIMMING POOL HEAT PUMP, AIR TO WATER HEAT PUMP:
* Copeland /Panasonic compressor & R410a/R417a refrigerant.
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
*Chinese No.1 brand "Gimleo" Titanium tube heat exchanger; 
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~30 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Air to Water Swimming Pool Heat Pump (S02H Series)
WHY US:
Air to Water Swimming Pool Heat Pump (S02H Series)
KONNEN NEW PROJECTS:
Air to Water Swimming Pool Heat Pump (S02H Series)
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Air to Water Swimming Pool Heat Pump (S02H Series)
KONNEN HEAT PUMPS LOADING:
Air to Water Swimming Pool Heat Pump (S02H Series)
PARAMETERS TABLE:
S02H series(Swimming pool heat pump)                                                                                                                                                                    SP-150301
    SP03PS-E3 SP05PS-E5 SP03P-E3 SP05P-E5 SP07P-E5 SP10P-C24 SP14P-C24 SP20P-C48 SP24P-C48 SP30P-C48 SP36P-C96 SP48P-C96
Rated heating capacity kW   14  24  14  24  32  48  66  95  115  145  170  230 
Rated input power kW   2.45  4.14  2.37  4.06  5.69  8.14  11.57  16.10  19.49  25.11  29.31  39.65 
Rated input current A   12.56  21.23  4.55  7.80  10.92  15.63  22.21  30.91  37.42  48.21  56.28  76.13 
COP  /   5.71  5.80  5.91  5.91  5.62  5.90  5.70  5.90  5.90  5.77  5.80  5.80 
*Heating capacity kW   12  20  12  20  25  40  52  80  95  120  145  190 
*Input power kW   2.30  3.88  2.33  3.80  4.87  7.62  9.98  15.36  18.20  22.81  27.83  36.19 
*Input current A   11.81  19.92  4.47  7.30  9.36  14.63  19.16  29.48  34.94  43.80  53.44  69.49 
*COP /   5.21  5.15  5.15  5.26  5.13  5.25  5.21  5.21  5.22  5.26  5.21  5.25 
Maximum input power kW   3.19  5.38  3.08  5.28  7.40  10.58  15.04  20.93  25.34  32.64  38.10  51.55 
Maxmum input current A   16.33  27.60  5.92  10.13  14.20  20.32  28.88  40.19  48.65  62.67  73.16  98.97 
Rated hot water output temperature' ºC 28 
Maximum hot water output temperature ºC 35 
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type   Fully closed scroll type
Start mode Directly start
Quantity Set   1 1 1 1 1 2 2 2 2 3 3 4
Water side heat exchanger Type Titanium tube heat exchanger
Water flow M3/h   6.02  10.32  6.02  10.32  13.76  20.64 28.38 40.85 49.45  62.35  73.10  98.90 
 Water pressure drop KPa ≤50 ≤70
Pipe size Φ   Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ90 Φ90 Φ110 Φ110
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection,
8. Water flow protection etc.
Noise DB(A)   ≤55 ≤63 ≤55 ≤63 ≤63 ≤65 ≤68 ≤70 ≤72 ≤73 ≤74 ≤78
Unit dimensions mm   700×700×870 820×695×1060 700×700×870 820×695×1060 820×695×1060 1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1980 1000×2050×1980 2000×2050×1980
Weight KG   100 160 100 160 165 335 365 600 660 840 860 1260
Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC
                             2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC
The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now