• Air to Water Heat Pump Water Heater with CE, Best Components, Tested in Laboratory
  • Air to Water Heat Pump Water Heater with CE, Best Components, Tested in Laboratory
  • Air to Water Heat Pump Water Heater with CE, Best Components, Tested in Laboratory
  • Air to Water Heat Pump Water Heater with CE, Best Components, Tested in Laboratory

Air to Water Heat Pump Water Heater with CE, Best Components, Tested in Laboratory

Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification: CE, ISO9001, CCC, CB, RoHS, SASO
Samples:
US$ 1100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HW03P-HW48P
Product Name
Commercial Use Air Source Heat Pump (Ckfxrs-70II)
Rated Heating Capacity
35kw
Suitable Environment
-25~52
Transport Package
Safety Export Packing, with Pallet
Specification
Standard
Trademark
KONNEN
Origin
China (Mainland)
HS Code
84189910
Production Capacity
500 Units/Month

Product Description

Air to Water Heat Pump Water Heater with CE, Best Components, Tested in LaboratoryCommercial Use Air Source Heat Pump (CKFXRS-35II):
Air to Water Heat Pump Water Heater with CE, Best Components, Tested in Laboratory

Air to Water Heat Pump Water Heater with CE, Best Components, Tested in Laboratory
* Sanyo compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporatorer;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* LCD controller;
* Delivery time: 20~25 days;
* Warranty time: 24 months after installation.
                               
                              
Air source heat pump:
1. Computer self-inspection and protection functions, low pollution operate
2. Evaporator applies clear water membrane, high absorbing ability, high efficiency, anti-corrosion
3. Convenient installation, small occupation, saves cost
4. Apply word famous compressor, 4-way valve, expansion value, the performance is higher and more stable.


Heat Pump,Air Source Heat Pump,Air to Water Heat Pump, Home Use Heat Pump,Commercial Use Heat Pump, Water Source Heat Pump,Water to Water Heat Pump, Ground Source Heat Pump,Geothermal Heat Pump,Domestic Use Heat Pump,Home Use Heat Pump,EVI Heat Pump,EVI System Air Source Heat Pump,Direct Air Source Heat Pump, Water Heater Heat Pump,Made In China Central Heating Heat Pump,Floor Warming Heat Pump.

A02H series   ( commercial use circulating type)                                                                                                                                                            CN/D-RYF-CA02HCY01-130514 
  CKFXRS-12 I CKFXRS-19 I CKFXRS-12 II   CKFXRS-19 II CKFXRS-25II CKFXRS-35 II CKFXRS-50 II CKFXRS-75 II CKFXRS-105 II
CA02H03A CA02H05A CA02H03B CA02H05B CA02H07A CA02H10A CA02H14A CA02H20A CA02H30A
Rated heating capacity KW 12  19  12  19  25  35  50  75  105 
Rated power KW 3.0  4.8  3.0  4.8  6.3  8.8  12.6  18.9  27.0 
Rated current A 15.5  24.6  5.7  9.1  11.9  16.7  23.9  35.8  51.0 
Maximum power KW 4.0  6.4  4.0  6.4  8.4  11.8  16.8  25.2  35.9 
Maximum current A 20.7  32.7  7.6  12.0  15.8  22.1  31.6  47.4  67.5 
Performance coefficient (COP) / 4.0  4.0  4.0  4.0  4.0  4.0  4.0  4.0  3.9 
Rated hot water output temperature C 55  55  55  55  55  55  55  55  55 
Maximum  hot water output temperature C 60  60  60  60  60  60  60  60  60 
Rated  hot water produce capacity L/H 257 408 257 408 515 760 1075 1612 2258 
Power supply 1N 220V/50Hz 3N 380V/50Hz
Alternative power supply (1N 208-230V/60Hz);  (1N 220-240V/50Hz); (3N 220-240V/50Hz)
( 3N 208-230V/60Hz); (3N 380-415V/50Hz); (3N 440-460V/60Hz); (3N 380V/60Hz)
Compressor Type Fully closed scroll type
Start mode Direct
Water side heat exchanger Type Shell and tube heat exchanger
Water flow M3/h 2.1  3.3  2.1  3.3  4.1  6.0  8.6  12.9  18.0 
 Water pressure drop KPa ≤ 50 ≤ 55 ≤ 50 ≤ 55 ≤ 55 ≤ 60 ≤ 70 ≤ 70 ≤ 72
Pipe size DN 20 25 20 25 25 32 32 50 50
Protections 1.High and low pressure protection,   2. Anti-freeze protection,    3. High temperature protection,                                                                                                           4. Overload protection,     5. Reverse of phase protection,  Lack of phase protection,  etc.
Refrigerant Type R410A
Weight(KG) 1.7 2.7 1.7 2.7 4.2 2.7x2 4.2x2 2.7x4 2.8x6
Noise ≤ DB ( A ) 55 63 55 63 68 68 68 69 70
Unit dimensions Length MM 700 820 700 820 820 1460 1460 2050 2641
Width MM 700 820 700 820 820 910 910 1100 1000
Height MM 870 1060 870 1060 1060 1430 1430 1935 1930
Weight KG 100 160 100 160 190 299 400 650 855
Note: 1. Hot water standard condition: use side  initial water temperature 15  C , end  water temperature 55  C ; dry-bulb temperature 20 C, wet bulb temperature 15 C .
   2. The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us.
   3. The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now