Swimming Pool Heat Pump for Swimming Pool Use

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Still deciding? Get samples of US$ 598/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Swimming Pool Heat Pump for Swimming Pool Use
  • Swimming Pool Heat Pump for Swimming Pool Use
  • Swimming Pool Heat Pump for Swimming Pool Use
  • Swimming Pool Heat Pump for Swimming Pool Use
  • Swimming Pool Heat Pump for Swimming Pool Use
  • Swimming Pool Heat Pump for Swimming Pool Use
Find Similar Products

Basic Info.

Work Environment
Common Heat Pump
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, SASO, TUV
Product Name
Swimming Pool Heat Pump Water Healter(12kw~230kw)
Rated Heating Capacity
24kw
Rated Outlet Hot Water Temperature
28
Maximum Outlet Hot Water Temperature
35
Compressor
Panasonic
Refrigerant
R410A
Power Supply
3n 380V/50Hz
Type
Heat Pump
Transport Package
Carton Packaging Plus Plywood
Specification
Grade A
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
10units /Day

Product Description

  • 24kW Swimming Pool Heat Pump with CE approved:

  • Long time of warranty

  • Machine casing: spray coating metal plate

  • Function: Production of hot water

  • Host machine color:  white

  • Accessories: LCD controller, pressurized water tank(150L, 200L, 300L, 500L)

  • Safety protecting system:

  • 1)High and low pressure protection

  • 2)Anti-freeze protection

  • 3)High temperature protection

  • 4)Safety valve

  • 5)Overload protection

  • 6)Reverse phase

  • 7)Lack of phase

  • 8)Separation of water and electricity

    Refrigerant: R22/R410A/R417a

    S02H series(Swimming pool heat pump)                                                                                                                                                                                                        SP-150301
      SP2.5PS-H2 SP03PS-E3 SP05PS-E5 SP03P-E3 SP05P-E5 SP07P-E5 SP10P-C24 SP14P-C24 SP20P-C48 SP24P-C48 SP30P-C48 SP36P-C96 SP40P-C96 SP48P-C96
    Rated heating capacity kW 12  14  24  14  24  32  48  66  95  115  145  170  190  230 
    Rated input power kW 2.11  2.45  4.14  2.37  4.06  5.69  8.14  11.57  16.10  19.49  25.11  29.31  32.76  39.65 
    Rated input current A 10.82  12.56  21.23  4.55  7.80  10.92  15.63  22.21  30.91  37.42  48.21  56.28  62.90  76.13 
    COP  / 5.59  5.71  5.80  5.91  5.91  5.62  5.90  5.70  5.90  5.90  5.77  5.80  5.80  5.80 
    *Heating capacity kW 12  20  12  20  25  40  52  80  95  120  145  160  190 
    *Input power kW 1.80  2.30  3.88  2.33  3.80  4.87  7.62  9.98  15.36  18.20  22.81  27.83  30.48  36.19 
    *Input current A 9.21  11.81  19.92  4.47  7.30  9.36  14.63  19.16  29.48  34.94  43.80  53.44  58.51  69.49 
    *COP / 5.01  5.21  5.15  5.15  5.26  5.13  5.25  5.21  5.21  5.22  5.26  5.21  5.25  5.25 
    Maximum input power kW 2.74  3.19  5.38  3.08  5.28  7.40  10.58  15.04  20.93  25.34  32.64  38.10  42.59  51.55 
    Maxmum input current A 14.05  16.33  27.60  5.92  10.13  14.20  20.32  28.88  40.19  48.65  62.67  73.16  81.77  98.97 
    Rated hot water output temperature' ºC 28 
    Maximum hot water output temperature ºC 35 
    Power supply 1N 220V/50Hz 3N 380V/50Hz
    Compressor Type Rotor type Fully closed scroll type
    Start mode Directly start
    Quantity Set 1 1 1 1 1 1 2 2 2 2 3 3 4 4
    Water side heat exchanger Type Titanium tube heat exchanger
    Water flow M3/h 5.07  6.02  10.32  6.02  10.32  13.76  20.64 28.38 40.85 49.45  62.35  73.10  81.70  98.90 
     Water pressure drop KPa ≤50 ≤70
    Pipe size Φ Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ90 Φ90 Φ110 Φ110 Φ110
    Protections 1. High pressure and low pressure protection, 
    2. Anti-freezing protection, 
    3. High temperature protection, 
    4. Too big of the water temperature difference for outlet and inlet protection, 
    5. Overload protection, 
    6. Lack phase protection, 
    7. Reverse phase protection,
    8. Water flow protection etc.
    Noise DB(A) ≤50 ≤55 ≤63 ≤55 ≤63 ≤63 ≤65 ≤68 ≤70 ≤72 ≤73 ≤74 ≤76 ≤78
    Unit dimensions mm 1000×360×
    630
    700×700×
    870
    820×695×
    1060
    700×700×
    870
    820×695×
    1060
    820×695×
    1060
    1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1980 2000×2050×1980 2000×2050×1980 2000×2050×1980
    Weight KG 64 100 160 100 160 165 335 365 600 660 840 860 1225 1260
    Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC
                                 2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC
    The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us.
    The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.



    Swimming Pool Heat Pump for Swimming Pool Use
    Swimming Pool Heat Pump for Swimming Pool Use

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier