CL11s-CW5 |
CL17s-CW5 |
CL11-CW5 |
CL17-CW5 |
CL24-CW5 |
CL34-CW10 |
CL48-CW10 |
CL68-CW20 |
CL80-CW20 |
CL120-CW20 |
CL160-CW20 |
Underground water open loop |
Rated cooling capacity |
KW |
11 |
17 |
11 |
17 |
24 |
34 |
48 |
68 |
80 |
120 |
160 |
Rated input power for cooling |
KW |
2.15 |
3.34 |
2.11 |
3.20 |
4.72 |
6.53 |
9.18 |
13.18 |
15.72 |
23.35 |
31.56 |
Rated input current for cooling |
A |
9.55 |
14.84 |
3.98 |
6.04 |
8.91 |
12.33 |
17.35 |
24.91 |
29.71 |
44.12 |
59.64 |
Cooling performance coefficient (EER) |
/ |
5.12 |
5.09 |
5.22 |
5.32 |
5.09 |
5.21 |
5.23 |
5.16 |
5.09 |
5.14 |
5.07 |
Rated heating capacity |
KW |
9.5 |
16 |
9.5 |
16 |
22 |
32 |
45 |
65 |
75 |
115 |
150 |
Rated input power for heating |
KW |
2.59 |
4.38 |
2.59 |
4.31 |
6.09 |
8.86 |
12.33 |
18.01 |
21.01 |
32.39 |
41.78 |
Rated input current for heating |
A |
12.33 |
20.87 |
4.89 |
8.15 |
11.52 |
16.75 |
23.30 |
34.03 |
39.71 |
61.23 |
78.97 |
Heating performance coefficient (COP) |
/ |
3.67 |
3.65 |
3.67 |
3.71 |
3.61 |
3.61 |
3.65 |
3.61 |
3.57 |
3.55 |
3.59 |
Application side heat exchanger water flow |
M3/h |
1.89 |
2.92 |
1.89 |
2.92 |
4.13 |
5.85 |
8.26 |
11.70 |
13.76 |
20.64 |
27.52 |
Heat source side heat exchanger water flow |
M3/h |
1.03 |
1.59 |
1.03 |
1.59 |
2.25 |
3.19 |
4.50 |
6.38 |
7.51 |
11.26 |
15.01 |
Ground source closed loop |
Rated cooling capacity |
KW |
10 |
16 |
10 |
16 |
22 |
32 |
46 |
64 |
76 |
114 |
150 |
Rated input power for cooling |
KW |
1.96 |
3.17 |
1.95 |
3.13 |
4.38 |
6.17 |
8.83 |
12.48 |
14.90 |
22.27 |
29.64 |
Rated input current for cooling |
A |
8.70 |
14.11 |
3.68 |
5.91 |
8.28 |
11.65 |
16.69 |
23.58 |
28.16 |
42.08 |
56.03 |
Cooling performance coefficient (EER) |
/ |
5.11 |
5.04 |
5.13 |
5.12 |
5.02 |
5.19 |
5.21 |
5.13 |
5.10 |
5.12 |
5.06 |
Rated heating capacity |
KW |
8 |
12 |
8 |
12 |
16 |
24 |
33 |
48 |
57 |
86 |
115 |
Rated input power for heating |
KW |
3.07 |
4.43 |
3.04 |
4.58 |
5.99 |
9.20 |
12.60 |
18.39 |
22.01 |
32.95 |
43.73 |
Rated input current for heating |
A |
13.27 |
19.17 |
5.66 |
8.52 |
11.15 |
17.10 |
23.43 |
34.21 |
40.93 |
61.29 |
81.33 |
Heating performance coefficient (COP) |
/ |
2.61 |
2.71 |
2.63 |
2.62 |
2.67 |
2.61 |
2.62 |
2.61 |
2.59 |
2.61 |
2.63 |
Application side heat exchanger water flow |
M3/h |
1.38 |
2.06 |
1.38 |
2.06 |
2.75 |
4.13 |
5.68 |
8.26 |
9.80 |
14.79 |
19.78 |
Heat source side heat exchanger water flow |
M3/h |
1.72 |
2.58 |
1.72 |
2.58 |
3.44 |
5.16 |
7.10 |
10.32 |
12.26 |
18.49 |
24.73 |
Power supply |
1N 220V/50Hz (Special power supply for option) |
3N 380V/50Hz(Special power supply for option) |
Compressor |
Type |
Hermetic scroll type |
Quantity |
PCS |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
3 |
4 |
Heat source side heat exchanger |
Type |
Shell & coil(tube) heat exchanger |
Connection size |
DN |
DN20 |
DN25 |
DN25 |
DN25 |
DN25 |
DN32 |
DN32 |
DN50 |
DN65 |
DN65 |
DN80 |
Application side heat exchanger |
Type |
Shell & coil(tube) heat exchanger |
Connection size |
DN |
DN20 |
DN25 |
DN25 |
DN25 |
DN25 |
DN32 |
DN32 |
DN50 |
DN65 |
DN65 |
DN80 |
Protections |
1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc. |
Refrigerant |
Type |
R410A |
Quantity |
KG |
2.6 |
3.3 |
2.6 |
3.3 |
4.2 |
3.3x2 |
4.2x2 |
6.6x2 |
7.6x2 |
7.6x3 |
7.6x4 |
Dimension |
mm |
790x415x590 |
790x710x950 |
2000x1000x1600 |
Wooden case package dimensions(L*W*H) |
mm |
836x461x752 |
836x756x1112 |
2056x1056x1768 |
Net weight |
KG |
68 |
95 |
65 |
95 |
135 |
195 |
320 |
795 |
885 |
1180 |
1210 |
Gross weight |
KG |
78 |
105 |
75 |
105 |
145 |
215 |
340 |
830 |
920 |
1215 |
1245 |
Noise |
DB(A) |
≤53 |
≤55 |
≤55 |
≤55 |
≤58 |
≤58 |
≤62 |
≤65 |
≤70 |
≤75 |
≤75 |
Note: |
1. Underground water open loop type cooling standard condition: application side water input/output temperature 12ºC/7ºC; source side water input/output temperature 18ºC/29ºC. Underground water open loop type heating standard condition: application side water input/output temperature 40ºC/45ºC; source side water input/output temperature 15ºC/-a. |
2. Ground source closed loop type cooling standard condition: application side water input/output temperature 12ºC/7ºC; source side water input/output temperature 25ºC/30ºC Ground source closed loop type heating standard condition: application side water input/output temperature 40ºC/45ºC ; source side water input/output temperature 5ºC/-a. |
3. "-a " means the water flow under cooling standard condition. |
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret. |