Customization: | Available |
---|---|
Energy Efficiency Grade: | One |
Heat Temperature: | 50-70°C |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
D03H series( EVI Air source heat pump Hot water use & Space heating) EFH-150307 | ||||
EFH3P-S5 | EFH5P-S5 | |||
Hot water Normal condition | Heating capacity | kW | 12 | 19 |
Input power | kW | 2.80 | 4.40 | |
Input current | A | 5.30 | 8.60 | |
COP | / | 4.29 | 4.32 | |
Hot water Nominal condition | Rated heating capacity | kW | 9.50 | 15.00 |
Rated input power | kW | 2.60 | 4.10 | |
Rated input current | A | 5.20 | 8.20 | |
COP | / | 3.65 | 3.66 | |
Hot water Low temperature condition | Heating capacity | kW | 5.50 | 8.80 |
Input power | kW | 2.26 | 3.65 | |
Input current | A | 4.29 | 6.93 | |
COP | / | 2.43 | 2.41 | |
Space heating standard conditions | Heating capacity | kW | 9 | 14.5 |
Input power | kW | 2.82 | 4.61 | |
Input current | A | 5.33 | 8.71 | |
COP | / | 3.19 | 3.15 | |
Maximum input power/current | kW/A | 3.61/6.92 | 5.71/11.20 | |
Rated hot water output temperature | ºC | 55 | ||
Rated space heating water output temperature | ºC | 45 | ||
Maximum water output temperature | ºC | 60 | ||
Rated hot water produce capacity | L/H | 204.25 | 322.5 | |
Power supply | 3N 380V/50Hz | |||
Compressor | Type | Fully closed scroll type | ||
Start mode | Directly start | |||
Water side heat exchanger | Type | Shell & coil heat exchanger | ||
Water flow | M3/h | 2.1 | 3.3 | |
Water pressure drop | KPa | ≤50 | ≤55 | |
Pipe size | DN | 25 | 25 | |
Middle heat exchanger | Type | Brazed plate type heat exchanger | ||
Protections | 1. High pressure and low pressure protection, 2. Anti-freezing protection, 3. High temperature protection, 4. Too big of the water temperature difference for outlet and inlet protection, 5. Overload protection, 6. Lack phase protection, 7. Reverse phase protection, etc.. |
|||
Noise | DB(A) | ≤55 | ≤58 | |
Unit dimensions | mm | 835×410×1330 | ||
Weight | KG | 115 | 175 | |
Testing condition: 1. Hot water normal condition: dry bulb 20ºC, wet bulb 15ºC; initial water temperature 15ºC, end water temperature 55ºC. 2.Hot water nominal condition: dry bulb 7ºC, wet bulb 6ºC; initial water temperature 9ºC, end water temperature 55ºC. 3. Hot water low temperature condition: dry bulb -12ºC, wet bulb -14ºC; initial water temperature 9ºC, end water temperature 55ºC. 4.Heating standard conditions: dry-bulb temperature 7ºC, wet bulb temperature 6ºC; Cold water inlet temperature 40ºC, outlet water temperature 45ºC. |
||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret. |