DC Inverter Split Air Source Heat Pump with Long Warrenty

Product Details
Customization: Available
Certification: SASO, CCC, ISO9001, CE, TUV
Working Medium: R410A
Still deciding? Get samples of US$ 1400/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • DC Inverter Split Air Source Heat Pump with Long Warrenty
  • DC Inverter Split Air Source Heat Pump with Long Warrenty
  • DC Inverter Split Air Source Heat Pump with Long Warrenty
  • DC Inverter Split Air Source Heat Pump with Long Warrenty
Find Similar Products

Basic Info.

Model NO.
RF8I/bdm --HF20I/bdm
Heat Source Type
Air Source Heat Pump
Product Name
Air to Water Heat Pump Water Heater
Rated Outlet Hot Water Temperature
55 Degree
Maximum Outlet Hot Water Temperature
58 Degree
Compressor
Gmcc
Refrigerant
R410A
Usage
Water Heater
Control Type
Digital
Display Type
LCD
Material
Colored Steel Casing
Working Range
-30--43 Degree
Power Supplier
220V/1/50Hz
Heating Capacity (Kw)
9kw-20kw
Power Input (Kw)
2.59-5.81
Cooling Capacity (Kw)
8-12
Cooling Input(Kw)
3.2-4.8
Transport Package
Safe Export Packing
Specification
RF8I/bd--RF16I/bd
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
2500units/Month

Product Description

KONNEN DC INVERTER AIR SOURCE HEAT PUMP, FOR COOLING +HEATING:
* GMCC Compressor with R410A;
* High efficiency hydrophilic aluminum foil fin heat exchanger;
* "SANHUA" EEV;
* "Lifeng" fan ;
* Delivery time:about 30days after received deposit;
* Payment:T/T 30% prepaid ,then pay for the balance before delivery;
*Package:ply-wood cases;
* Warrenty:18month;

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
DC Inverter Split Air Source Heat Pump with Long Warrenty
WHY US:
DC Inverter Split Air Source Heat Pump with Long Warrenty
KONNEN NEW PROJECTS:
DC Inverter Split Air Source Heat Pump with Long Warrenty
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
DC Inverter Split Air Source Heat Pump with Long Warrenty
KONNEN HEAT PUMPS LOADING:
DC Inverter Split Air Source Heat Pump with Long Warrenty
PARAMETERS TABLE:
DC INVERTER SPLIT TYPE HEAT PUMP FOR COOLING & HEATING
Model RF8I/bdm
(3HP)
RF12I/bdm
 (5HP)
RF13I/bdm
(6HP)
HF20I/bdm (8HP)
Rated Heating Heating capacity kW 9.00  15.00  18.00  20.00 
Power input kW 2.59  4.31  5.14  5.81 
COP W/W 3.47  3.48  3.50  3.44 
Nominal Heating Heating capacity kW 5.53  10.50  12.10  14.50 
Power input kW 2.34  4.43  5.13  6.01 
COP W/W 2.36  2.37  2.36  2.41 
IPLV(H) W/W 2.80  2.85  2.85  2.86 
Low Temp. Heating Heating capacity kW 4.50  8.90  10.10  12.50 
Power input kW 2.34  4.56  5.10  5.95 
COP W/W 1.92  1.95  1.98  2.10 
Rated Cooling Cooling capacity kW 8.00  11.50  12.00  /
Power input kW 3.20  4.60  4.80  /
EER W/W 2.50  2.50  2.50  /
Power Supply V/Ph/Hz 220/1/50
Max. Power Input
(With E-Heater)
kW 4.4(+3) 5.2(+3) 6.6(+3) 7.1(+3)
Max. Current Input
(With E-Heater)
A 20(+13.6) 23.7(+13.6) 30(+13.6) 32.5(+13.6A)
Max. Water Temp.
(Without E-Heater)
ºC 58
Working Range
(Ambient temp.)
ºC -30 to 43 -35 to 43
Cooling Circulation Refrigerant Type R410A
Qty./Kg 1.7 3.15 3.15 3.15
Compressor Qty. 1
Type DC INVERTER DOUBLE ROTOR EVI DC INVERTER DOUBLE ROTOR
Brand GMCC
Evaporator Type High efficiency hydrophilic aluminum foil fin heat exchanger
EEV Brand SANHUA
Fan Motor Qty. 1 2
Power Input(W) 140 2*150
Fan Blades Size mm Φ560*139 Φ525*135
Liquid valve size inch(mm) 3/8"(9.52)
Gas valve size inch(mm) 5/8"(15.88)
Water system Condenser Type Tube in tube heat exchanger
Water Pump Brand XINHU
Model GPD25-12S
Water Flow m3/h 1.38 1.98 2.06 2.5
Water Drop kpa 35 35 38 48
Air Vent Valve   Standard
Pressure Release Valve   Standard
Pressure value 3kgs
E-Heater kW 3
Buffer Tank L 5
Water Inlet/Outlet Pipe Size inch(mm) 5/4" male
Net Dimensions indoor Unit (L*W*H) mm 760x510x330
Outdoor Unit (L*W*H) mm 947x403x813 940x393x1373
Package Size indoor Unit (L*W*H) mm 795x562x373
Outdoor Unit (L*W*H) mm 1050x468x847 1060x490x1395
N.W. Indoor Unit kg 43
Outdoor Unit kg 63 110 115
G.W. Indoor Unit kg 48
Outdoor Unit kg 70 125 130
Noise Level Indoor Unit dB(A) ≤35
Outdoor Unit dB(A) ≤59.5 ≤61.5 ≤62
Product implementation standards: GB/T 25127.2-2010 GB/T 18430.2-2016                                                                                                       
Testing Condition:                                                                                                                          
- Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
- Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant.           
                                                                                        

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier