• High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
  • High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
  • High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
  • High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
  • High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
  • High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi

High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi

Energy Efficiency Grade: One
Heat Temperature: 40-60°c
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RF7I/BR---RF17I/BR
Certification
CE, CCC, SASO, TUV
Transport Package
Wooden and Carton
Specification
CKXRS-3.5IH ----9.0IH
Trademark
KONNEN
Origin
Zhejiang
HS Code
8418612090
Production Capacity
3800units/Year

Product Description

KONNEN HOME USE AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, DOMESTIC HOT WATER :
* GMCC Compressor with R410a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time:18 months after delivery.

WE SUPPLY OEM SERVICE!


Features:
Split-type design and independent water tanks for flexible and convenient connection of water pipes.
Flexible installation of main unit and water tank.
Dynamic heat exchange between water and coolant as there is no coolant pipe in the water tank. This will reduce the damping of the heat exchanger and thus ensure adequate flow of water, prevent leakage caused by corrosion of copper tube, and reduce scale formation in the system.
Free selection of water tank sizes.
Stainless steel water tank with good insulation and less scale formation to ensure the quality of water.
Isolated water and electricity system to ensure operating safety.
Constant Outlet Water Temperature

Water temperature can be set between 40 degrees and 60 degrees, with an difference of less than 1degrees. The outlet temperature can be easily controlled and the adjustment will cause no significant change in water temperature. Whether the outlet quantity is increased or decreased, the water temperature will remain unchanged.

The RL series can produce constant temperature water no matter how the flow is adjusted. In the case of common gas water heaters, the water temperature will change when the flow is adjusted. The temperature will go down when the outlet flow is decreased; Otherwise, it will go up. A sudden rise in water temperature may cause skin burns. When the water flow is too small, the heater may be choked off. For those with a complicated pipe system, the water temperature will be more difficult to control.


KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
WHY US:
High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
KONNEN NEW PROJECTS:
High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
KONNEN HEAT PUMPS LOADING:
High Performance Monoblock Air Soure DC Inevrter Heat Pump Water Heat with WiFi
PARAMETERS TABLE:
             
POLESTAR series DC INVERTER MONOBLOCK TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER
Model RF8I/bd RF12I/bd RF16I/bd RF20I/bd RF20II/bd
Power Supply V/Ph/Hz 220~240/1/50 380/3/50
Rated Condition 7ºC Heating Capacity (KW) 8.5 15 18 20 20
Power Input (KW) 2.66 4.36 5.21 5.88 5.88
COP 3.2 3.44 3.45 3.4 3.4
Nominal Condition -12ºC Heating Capacity (KW) 5.50  10.50  12.13  14.5 14.5
Power Input (KW) 2.33  4.40  5.05  6.01 6.02
COP 2.36  2.40  2.40  2.41 2.41
Low Temp. Condition -20ºC Heating Capacity (KW) 4.70  9.21  10.52  12.5 12.5
Power Input (KW) 2.47  4.56  5.18  6.25 6.25
COP 1.90  2.02  2.03  2 2
Low Temp. Condition -25ºC/Water output temp. 41ºC Heating Capacity (KW) 3.55  6.82  8.76  10.35 10.35
Power Input (KW) 2.20  4.21  5.03  6.02 6.02
COP 1.61  1.62  1.74  1.72 1.72
Low Temp. Condition -25ºC/Water output temp. 50ºC Heating Capacity (KW) 3.19  6.14  8.08  9.59 9.58
Power Input (KW) 2.28  4.23  5.69  6.81 6.81
COP 1.40  1.42  1.42  1.41 1.41
Rated Cooling Condition Cooling capacity (KW) 7.00  11.50  12.00  15.00  15.00 
Power input (KW) 2.64  4.34  4.61  5.75 5.74
EER 2.65  2.65  2.60  2.61 2.61
Max. power input (KW) 4.4 5.2 6.6 7.1 8.5
Max. current Without E-heater (A)  20 23.7 30 32.5 15.5
Max. Water Output Temp. Under Ambient Temp. -25ºC 58 58 58 58 58
Water resistance (kPa) 35 38 43 54 50
Noise Level dB(A) 59.5 61.5 61.5 62 63
Refrigerant  R410A R410A R410A R410A R410A
Water Flow 0.95 m³/h 1.98 m³/h 2.06 m³/h 2.5 2.5
Pipe Size DN20 DN25
Dimensions(mm) 920*365*710 940*393*1373
Net Weight 60Kg 130kg 130kg 140kg 145kg
Testing Condition:                                                                                                                          
- Rated condition: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.