DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
  • DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
  • DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
  • DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
  • DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
  • DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
Find Similar Products

Basic Info.

Work Environment
Low-temperature Heat Pump
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons, DC Inverter Heat Pump
Certification
CE, ISO9001, CCC
Product Name
Air to Water Heat Pump Water Heater
Air to Water Heat Pump Water Heater
55 Degree
Maximum Outlet Hot Water Temperature
60 Degree
Compressor
Gmcc
Refrigerant
R410A
Usage
Water Heater
Control Type
Digital
Display Type
LCD
Material
Colored Steel Casing
Working Range
-30--43 Degree
Power Supplier
220V/1/50Hz
Heating Capacity
8.8kw-17kw
Power Input (Kw)
2.55-4.91
Cooling Capacity (Kw)
8-12
Cooling Input(Kw)
3.2-4.8
Transport Package
Plywood Cases
Specification
RF8I/bd--RF16I/bd
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
2500units/Month

Product Description

KONNEN DC INVERTER AIR SOURCE HEAT PUMP, FOR COOLING +HEATING:
* GMCC Compressor with R410A;
* High efficiency hydrophilic aluminum foil fin heat exchanger;
* "SANHUA" EEV;
* "Lifeng" fan ;
* Delivery time:about 30days after received deposit;
* Payment:T/T 30% prepaid ,then pay for the balance before delivery;
*Package:ply-wood cases;
* Warrenty:18month;

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot WaterKONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
WHY US:
DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
KONNEN NEW PROJECTS:
DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
KONNEN HEAT PUMPS LOADING:
DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
PARAMETERS TABLE:
Model RF8I/bd RF12/bd RF16I/bd
Power Supply V/Ph/Hz 220/1/50
Rated Current Input Without E-heater (A) 20 24 30
Rated Condition 7ºC Heating Capacity (KW) 8.8 12 17
Power Input (KW) 2.55 3.55 4.91
COP 3.45 3.4 3.5
Nominal Condition -12ºC Heating Capacity (KW) 5.41  10.50  12.13 
Power Input (KW) 2.25  4.40  5.05 
COP 2.40  2.40  2.40 
Low Temp. Condition -20ºC Heating Capacity (KW) 4.78  9.21  10.52 
Power Input (KW) 2.45  4.56  5.18 
COP 1.95  2.02  2.03 
Low Temp. Condition -25ºC/Water output temp. 41ºC Heating Capacity (KW) 3.55  6.82  7.80 
Power Input (KW) 2.20  4.21  4.81 
COP 1.61  1.62  1.62 
Low Temp. Condition -25ºC/Water output temp. 50ºC Heating Capacity (KW) 3.19  6.14  7.02 
Power Input (KW) 2.28  4.23  4.91 
COP 1.40  1.42  1.43 
Rated Cooling Condition Cooling capacity (KW) 8.00  11.50  12.00 
Power input (KW) 3.20  4.60  4.80 
EER 2.50  2.50  2.50 
Max. Water Output Temp. Under Ambient Temp. -25ºC 56.2ºC 56.1ºC 56.2ºC
Noise Level dB(A) 59.5 60.5 61.5
Refrigerant R410A R410A R410A
Water Flow 1.38 m³/h 1.92 m³/h 2.67 m³/h
Pipe Size DN20 DN25 DN25
Dimensions 947*403*813mm 940*393*1373mm 940*393*1373mm
Net Weight 80Kg 110kg 110kg
Testing Condition:                                                                                                                          
- Rated condition: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
- Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant.
DC Inverter Air Source Heat Pump for Cooling, Heating and Sanitary Hot Water
heat pump,DC heat pump,DC inverter heat pump,air to water heat pump,air source heat pump,heat pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier