Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Still deciding? Get samples of US$ 598/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory
  • Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory
  • Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory
  • Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory
  • Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory
Find Similar Products

Basic Info.

Model NO.
CKFXRS-12II/d, CKFXRS-19II/d, CKFXRS-35II/d
Work Environment
Low-temperature Heat Pump
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, SASO
Rated Heating Capacity
12kw, 19kw, 36kw,55kw, 75kw, 105kw, 145kw
Compressor
Copeland
Type
Side Blowing
Cop at Ambient Temp. -25c
1.8
Heat Exchanger
Swep
Control System Brand
Konnen
Transport Package
Safe Export Packing, With Pallet
Specification
CE
Trademark
KONNEN
Origin
China (Mainland)
Production Capacity
2000 Units/Month

Product Description

EVI air source heat pump with Copeland compressor and tested in our national proved laboratory.
More than 6 months testing for all kinds of conditions, lowest ambient temperature tested -20C.
Use our own control system which allows the best controlling for EVI heat pump in China.
We can sure that our EVI heat pump can reach one of the best performance and COP in China.
Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory
Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory
Evi Low Temperature Air Source Heat Pump Lowest Working Temp. -25c, Tested in National Proved Laboratory
AIR TO WATER HEAT PUMP WATER HEATER
AIR SOURCE HEAT PUMP WATER HEATER
EVI AIR SOURCE HEAT PUMP
EVI AIR TO WATER HEAT PUMP
LOW TEMPERATURE HEAT PUMP
 
A02U series( EVI air source heat pump low temperature type)                                                                                                                                             EVI-150307
  EVI3P-S5 EVI5P-S5 EVI10P-C24 EVI15P-C24 EVI20P-C48 EVI30P-C48 EVI40P-C96
Normal condition Heating capacity kW 12 19 36 55 75 105 145
Input power kW 2.80  4.40  8.20  12.70  17.10  24.10  33.20 
Input current A 5.30  8.60  14.80  24.20  33.00  45.10  62.50 
COP / 4.29  4.32  4.39  4.32  4.39  4.36  4.37 
Nominal  condition Rated heating capacity kW 9.50  15.00  30.00  45.00  60.00  90.00  120.00 
Rated input power kW 2.60  4.10  8.10  12.20  16.10  24.50  32.50 
Rated input current A 5.20  8.20  15.30  23.10  30.20  46.00  61.10 
COP / 3.65  3.66  3.70  3.68  3.73  3.67  3.69 
Low temperature condition Heating capacity kW 5.50  8.80  17.50  15.30  36.50  52.50  70.00 
Input power kW 2.26  3.65  7.30  6.41  15.10  21.60  29.10 
Input current A 4.29  6.93  13.00  12.10  28.10  40.80  54.80 
COP / 2.43  2.41  2.40  2.39  2.42  2.43  2.41 
Maximum input power/current kW/A 3.61/6.92 5.71/11.20 10.62/20.75 16.52/32.23 22.27/43.36 31.38/612 42.92/83.62
Rated hot water output temperature ºC 55
Maximum hot water output temperature ºC 60
Rated hot water produce capacity L/H 204.25 322.5 645 967.5 1290 1935 2580
Power supply 3N 380V/50Hz
Compressor Type Fully closed scroll type
Start mode Directly start
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow M3/h 2.1  3.3  6.0  9.5  12.9  18.0  24.9 
Water pressure drop KPa ≤50 ≤55 ≤60 ≤60 ≤65 ≤65 ≤65
Pipe size DN 25 25 32 32 50 65 65
Middle heat exchanger Type Brazed plate type heat exchanger
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Noise DB(A) ≤55 ≤58 ≤65 ≤68 ≤70 ≤73 ≤74
Unit dimensions mm 835×410×1330 1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1980 2000×2050×1980
Weight KG 115 175 355 425 620 855 1250
Testing condition: 1. Normal condition: dry bulb 20ºC, wet bulb 15ºC; initial water temperature 15ºC, end water temperature 55ºC.
                          2. Nominal condition: dry bulb 7ºC, wet bulb 6ºC; initial water temperature 9ºC, end water temperature 55ºC.
                          3. Low temperature condition: dry bulb -12ºC, wet bulb -14ºC; initial water temperature 9ºC, end water temperature 55ºC.
 
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier