Home Use Water Heater (circulating heating)

Product Details
Customization: Available
Outlet Water Max Temp: 60 Celsius Degree
Outlet Water Rated Temp.: 55 Celsius Degree
Still deciding? Get samples of US$ 598/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Home Use Water Heater (circulating heating)
  • Home Use Water Heater (circulating heating)
  • Home Use Water Heater (circulating heating)
  • Home Use Water Heater (circulating heating)
  • Home Use Water Heater (circulating heating)
  • Home Use Water Heater (circulating heating)
Find Similar Products

Basic Info.

Model NO.
A02H
Refrigerant
R410A
Compressor
Panasonic
Transport Package
Standard Export Packing
Trademark
CREATIVE POWER
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
500 PCS Per Month

Product Description

KONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
*  AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Home Use Water Heater (circulating heating)
WHY US:
Home Use Water Heater (circulating heating)
KONNEN NEW PROJECTS:
Home Use Water Heater (circulating heating)
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Home Use Water Heater (circulating heating)
KONNEN HEAT PUMPS LOADING:
Home Use Water Heater (circulating heating)
PARAMETERS TABLE:

 A02H series (Air source heat pump water heater circulation type)                                                                                                                                          
  HW03Ps-E3 HW05Ps-E5 HW03P-E3  HW05P-E5 HW07P-E5 HW10P-C24 HW14P-C24 HW20P-C48 HW24P-C48 HW30P-C48 HW36P-C48 HW48P-C96
Rated heating capacity kW 12 19 12 19 25 35 50  75 85 105 125 165
Rated input power kW 2.75  4.39  2.75  4.37  5.75  8.10  11.57  17.20  19.60  24.20  28.90  38.10 
Rated input current A 14.05  23.10  5.17  8.34  10.77  15.00  23.86  31.80  37.00  46.10  53.50  72.30 
Maximum input power kW 3.38  5.40  3.38  5.38  7.07  9.96  14.23  21.16  24.11  29.77  35.55  46.86 
Maximum input current A 18.28  29.19  6.43  10.21  13.44  18.93  27.05  40.20  45.81  56.56  67.54  89.04 
Performance coefficient(COP) / 4.36  4.33  4.36  4.35  4.35  4.33  4.32  4.36  4.34  4.34  4.33  4.33 
Rated hot water output temp. ºC 55 
Max. hot water output temp. ºC 60 
Rated hot water produce capacity L/H 258 408 258 408 537 752.5 1075 1612.5 1827.5 2257.5 2687.5 3547.5
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Fully closed scroll type
Start Mode Directly start
Quantity Set 1 1 1 1 1 2 2 4 2 3 3 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 2.1  3.3  2.1  3.3  4.3  6.0  8.6  12.9  14.6  18.1  21.5  28.4 
Water Pressure Drop kPa ≤50 ≤55 ≤50 ≤55 ≤55 <60 <60 <65 <65 <65 <65 <65
Pipe size DN DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN65 DN80
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Refrigerant Throttle Type Electronic expansion valve
Quantity kg 1.9 2.8 1.9 2.8 4.1 2.8×2 4.1×2 3.2×4 7.6×2 6.2×3 7.6×3 7.6×4
Noise DB(A) ≤55 ≤63 ≤55 ≤63 ≤65 ≤65 ≤68 ≤70 ≤72 ≤73 ≤74 ≤78
Dimension mm 700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1060
1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1980 1000×2050×1980 2000×2050×1980
Net Weight kg 100 160 100 160 190 310 400 605 650 835 840 1230
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. 
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.
Domestic Air Source Heat Pump Water Heater
Air Source Heat Pump
Air to water Heat Pump
Air-source heat pump Cycling Water Heater Home Use Series:
Suitable for households of 2-13 people
By creating comfortable living conditions
So that you can enjoy
Hot water bath
And fashionable life
In your own house

Features:
Split-type design and independent water tanks for flexible and convenient connection of water pipes.
Flexible installation of main unit and water tank.
Dynamic heat exchange between water and coolant as there is no coolant pipe in the water tank. This will reduce the damping of the heat exchanger and thus ensure adequate flow of water, prevent leakage caused by corrosion of copper tube, and reduce scale formation in the system.
Free selection of water tank sizes.
Stainless steel water tank with good insulation and less scale formation to ensure the quality of water.
Isolated water and electricity system to ensure operating safety.
Constant Outlet Water Temperature

Water temperature can be set between 40 degrees and 60 degrees, with an difference of less than 1degrees. The outlet temperature can be easily controlled and the adjustment will cause no significant change in water temperature. Whether the outlet quantity is increased or decreased, the water temperature will remain unchanged.

The RL series can produce constant temperature water no matter how the flow is adjusted. In the case of common gas water heaters, the water temperature will change when the flow is adjusted. The temperature will go down when the outlet flow is decreased; Otherwise, it will go up. A sudden rise in water temperature may cause skin burns. When the water flow is too small, the heater may be choked off. For those with a complicated pipe system, the water temperature will be more difficult to control.

Convenient Use of Hot Water.
Air Source Heat Pump Domestic Type (circulation type)
                              Model                                    Parameter KXRS-3.5 IH KXRS-5.0 IH KXRS-7.0 IH KXRS-9.0 IH
Rated Heating capacity   (KW) 3.5 5 7 9
Rated outlet hot water quantity (L/H) 75 107 150 193
Outlet water rated temp  ( C ) 55
Outlet water max temp  ( C ) 60
Electricity Parameter  Rated power   (KW) 0.9 1.24 1.71 2.26
Rated current   (A) 4.1 5.6 7.8 10.3
Power supply 220V~/50HZ
Max power   (KW) 1.25 1.58 2.25 2.72
Max current    (A) 5.7 7.2 10.3 12.4
Refrigerant R410a(R134a/R407c/R22)
Dimensions mm 950*360*560 1010*360*630
Weight KG  40 60 67 72
Waterproof grade IPX4
Defend electric shock grade GRADE 1
Noise Db 50Db  53Db 
Compressor Panasonic
Testing Conditions            Ambient Temperature               Water Inlet/Outlet Temp.
Dry Bulb Temp. Wet Bulb Temp. Water Inlet Temp. Water Outlet Temp.
20C 15C 15C 55C
 
Water Tank
Specifications 150L 200L 300L 500L
Pipe size (mm) 2 x DN15 2 x DN20
Water Tank Size φ470 x 1390 φ520 x 1535 φ620 x 1455 φ700 x 1775
Installation  floor type
Concurrent User 3-4 people 4-5 people 6-8 people 10-13 people

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier