Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 28-35°c
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
  • Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
  • Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
  • Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
  • Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
  • Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
Find Similar Products

Basic Info.

Model NO.
SP3P-SP48P (14kw-230kw)
Work Environment
Common Heat Pump
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC
Rated Heating Capacity (Kw)
14kw-230kw
Rated Input Power (Kw)
2.45kw-39.65kw
Transport Package
Safe Packing Export, with Pallet
Specification
standard
Trademark
KONNEN
Origin
Zhejiang, China
HS Code
8418612090
Production Capacity
2500units/Month

Product Description

KONNEN SWIMMING POOL HEAT PUMP, AIR TO WATER HEAT PUMP:
* Copeland /Panasonic compressor & R410a/R417a refrigerant.
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
*Chinese No.1 brand "Gimleo" Titanium tube heat exchanger; 
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~30 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
WHY US:
Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
KONNEN NEW PROJECTS:
Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
KONNEN HEAT PUMPS LOADING:
Swimming Pool Heat Pump Water Heater with Long Warrenty (14KW-230KW)
PARAMETERS TABLE: 
Wave series(Swimming pool heat pump)
  SP2.5PS-H2 SP03PS-E3 SP05PS-E5 SP03P-E3 SP05P-E5 SP07P-E5 SP10P-E10 SP14P-E10 SP20P-E20 SP24P-E20 SP30P-E20 SP40P-C96 SP48P-C96 SP60P-C96
Rated heating capacity kW 11.8  13.8  24.1  13.8  24.1  31.5  47.5  63.3  92.8  112.6  143.3  190.0  230.0  280.0 
Rated input power kW 2.21  2.63  4.51  2.64  4.52  6.01  9.06  12.10  16.96  20.91  26.49  34.0  40.9  49.7 
Rated input current A 12.82  15.36  25.93  5.01  8.61  11.94  17.51  23.04  32.91  40.42  50.58  65.0  77.9  94.5 
COP / 5.34  5.25  5.34  5.23  5.33  5.24  5.24  5.23  5.47  5.38  5.41  5.6  5.6  5.6 
*Heating capacity kW 8.9  11.8  19.7  11.9  20.1  24.7  39.8  50.4  77.2  92.5  115.7  160.0  190.0  230.0 
*Input power kW 1.86  2.47  4.14  2.45  4.12  5.18  8.30  10.57  15.66  18.77  23.81  30.5  36.0  44.1 
*Input current A 10.66  14.24  23.65  4.70  7.82  9.85  15.98  20.12  29.85  35.65  45.35  58.0  68.9  83.7 
*COP / 4.78  4.78  4.76  4.86  4.88  4.77  4.80  4.77  4.93  4.93  4.86  5.3  5.3  5.2 
**Cooling capacity kW 8.74  11.65  19.42  11.65  19.42  24.27  38.83  50.49  77.67  92.23  116.50  155.35  184.47  220.25 
**Input power kW 2.33  3.08  5.06  3.04  5.08  6.34  10.25  13.25  20.39  24.21  30.66  40.98  48.92  58.27 
**Input current A 12.26  16.22  26.61  5.78  9.66  12.04  19.47  25.18  38.73  46.00  58.25  77.87  92.96  110.67 
**EER / 3.75  3.78  3.84  3.83  3.82  3.83  3.79  3.81  3.81  3.81  3.80  3.79  3.77  3.78 
Maximum input power kW 2.87  3.42  5.86  3.43  5.88  7.81  11.78  15.73  22.05  27.18  34.44  44.2  53.1  62.8 
Maxmum input current A 14.05  16.33  27.60  5.92  10.13  14.20  20.32  28.88  40.19  48.65  62.67  81.8  99.0  120.2 
Rated hot water output temperature ºC 28 
Maximum hot water output temperature ºC 40 
Rated cooling water output temperature ºC 12 
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Rotor type Hermetic scroll type
Start mode Directly start
Quantity Set 1 1 1 1 1 1 2 2 4 4 4 4 4 4
Water side heat exchanger Type Titanium tube heat exchanger
Water flow M3/h 5.07  6.02  10.32  6.02  10.32  13.76  20.64 28.38 40.85 49.45  62.35  81.70  98.90  124.70 
Water pressure drop KPa ≤50 ≤70
Pipe size Φ Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ50 Φ90 Φ90 Φ90 Φ110 Φ110 Φ110
Protections 1. High pressure and low pressure protection,
2. Anti-freezing protection,
3. High temperature protection,
4. Too big of the water temperature difference for outlet and inlet protection,
5. Overload protection,
6. Lack phase protection,
7. Reverse phase protection,
8. Water flow protection etc.
Noise DB(A) ≤50 ≤55 ≤63 ≤55 ≤63 ≤63 ≤65 ≤68 ≤70 ≤70 ≤70 ≤76 ≤78 ≤80
Unit dimensions mm 1000×360×
630
700×700×
870
820×695×
1060
700×700×
870
820×695×
1060
820×695×
1060
1502×750×1060 1502×750×1060 1995×1165×1105 1995×1165×1105 1995×1165×1105 2000×2050×1980 2000×2050×1980 2000×2050×1980
Weight KG 64 100 160 100 160 190 255 400 600 725 855 1225 1260 1310
Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC.
2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC.
3. ** Cooling: Ambient temp.(DB/WB): 35ºC/24ºC; Water temp.(In/Out):29ºC/27ºC
Cooling function for option, if your require cooling function, please let us know in advance.
The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier