Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C

Product Details
Customization: Available
Heat Temperature: 70~80 Deg C
Work Environment: Common Heat Pump
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
  • Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
  • Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
  • Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
  • Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
  • Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
Find Similar Products

Basic Info.

Model NO.
A03H
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB, RoHS, SASO
Product Name
Commercial Use Air Source Heat Pump (Ckfxrs-70II)
Rated Heating Capacity
8kw~130kw
Suitable Environment
-25~52
Color
Dark Black-Grey
Controller
Konnen Brand
Testing
25HP National Proved Laboratory
Transport Package
Safety Export Packing, with Pallet
Specification
Standard
Trademark
KONNEN
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
500 Units/Month

Product Description

High temperature air to water heat pump water heater, with Copeland compressor and R134a refrigerant, max. water output temperature 80 deg C, 8KW to 155KW.
* Copeland compressor & R134a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* KONNEN LCD controller;
* Delivery time: 25~30 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
WHY US:
Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
KONNEN NEW PROJECTS:
Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
WORLD FAMOUS BRAND WE COOPERATED FOR OUR HEAT PUMPS:
Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
HEAT PUMP LOADING:
Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
PRODUCT FEATURES:
Air to Water Heat Pump for Water Output Temperature Max. 80 Deg C
PARAMETERS TABLE:
A03H (High temperature air source heat pump water heater circulation type)                                                                                                           
  HT3Ps-T3 HT5sP-T5 HT3P-T3 HT5P-T5 HT7P-T5 HT10P-C24 HT14P-C24 HT20P-C48 HT24P-C48 HT30P-C48 HT36P-C48 HT48P-C96
Rated heating capacity kW 8 13.5 8 13.5 18 26 35 55 65 80 95 130
Rated input power kW 2.2 3.65 2.19  3.66  4.96  7.11  9.62  14.91  17.81  21.98  26.03  35.81 
Rated input current A 9.58 15.9 4.14  6.92  9.37  13.55  18.17  28.17  33.66  41.54  49.19  67.69 
Maximum input power kW 2.86 4.75 2.74  4.58  6.20  8.89  12.02  18.63  22.26  27.47  32.53  44.77 
Maximum input current A 14.92 24.77 5.34  8.92  12.09  17.33  23.44  36.33  43.41  53.57  63.44  87.29 
Performance coefficient(COP) / 3.63 3.69 3.65  3.69  3.63  3.65  3.64  3.69  3.65  3.64  3.65  3.63 
Rated hot water output temp. ºC 75
Maximum hot water output temp. ºC 80
Rated hot water produce capacity t40 L/H 172.0  290.2  172.0  290.3  387.0  559.0  752.5  1182.5  1397.5  1720.0  2042.5  2795.0 
t60 L/H 114.7  193.5  114.7  193.5  258.0  372.7  501.7  788.3  931.7  1146.7  1361.7  1863.3 
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Hermetic scroll type
Start Mode Directly start
Quantity Set 1 1 1 1 1 2 2 4 2 3 3 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 1.4  2.3  1.4  2.3  3.1  4.5  6.0  9.5  11.2  13.8  16.3  22.4 
Water Pressure Drop kPa ≤45 ≤53 <50 <55 <57 <60 <60 <65 <65 <65 <65 <65
Pipe size mm DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN65 DN80
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Refrigerant Type R134a
Throttle Type Electronic expansion valve
Quantity kg 2.1 3.3 2.1 3.3 4.3 2.8×2 4.1×3 3.2×4 7.6×2 6.2*3 7.6×3 7.6×4
Noise DB(A) 55 63 55 63 65 65 68 70 72 73 74 78
Dimension mm 700×680×
875
860×820×
1080
700×680×
875
860×820×
1080
860×820×
1080
1000×1000×
1858
1000×1000×
1858
1000×2050×
1900
1000×2050×
1900
1000×2050×
1980
1000×2050×
1980
2000×2050×
1980
Net Weight kg 100 170 100 170 190 310 410 605 650 835 840 1250
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 75ºC, max. temperature 80ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC
The above parameters are based on Refrigearnt R134a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any  business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

AIR TO WATER HEAT PUMP, AIR SOURCE HEAT PUMP, HIGH TEMPERATURE HEAT PUMP, HEAT PUMP WATER HEATER.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier