Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved

Product Details
Customization: Available
Heat Temperature: 10c-45c
Work Environment: Common Heat Pump
Still deciding? Get samples of US$ 980/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved
  • Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved
  • Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved
  • Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved
Find Similar Products

Basic Info.

Model NO.
W02F Series
Heat Source
Water-source
Heating Type
Circulating Heat
Application
Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC
Rated Heating Capacity
8kw-190kw
Refrigerant
R410A
Transport Package
Plywood Case or Carton
Specification
CE
Trademark
CEN
Origin
Zhejiang, China
HS Code
8418612090
Production Capacity
1500units/Month

Product Description

KONNEN WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, WITH COPELAND COMPRESSOR AND R410A REFRIGERANT:
* Panasonic compressor & R410a refrigerant or Copeland compressor & R410a refrigerant;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Schneider AC contactor and relay
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* KONNEN LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY 2017(HEAT PUMP + WATER TANK + CONTROLLER):

Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved
WHY US:
Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved
KONNEN NEW PROJECTS:
Brine Water to Water Heat Pump for Space Heating / Cooling with Ce ApprovedKONNEN HEAT PUMPS FOR EXPORTING:
Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved

WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved
PRODUCT FEATURES:
Brine Water to Water Heat Pump for Space Heating / Cooling with Ce Approved

PARAMETERS TABLE:
Ground source heat pump for Cooling/Heating
  CRS13/S CRS17/S CRS19/S CRS28/S CRS38/S CRS56/S
(CS02W035S) (CS02W046S) (CS02W050S) (CS02W080S) (CS02W100S) (CS02W160S)
Underground water type Rated cooling capacity KW 13.5 17.5 19.1 28.1 38.1 56.2
Rated input power for cooling KW 2.54 3.24 3.33 5.25 6.67 10.62
Rated input current for cooling A 12.81 15.82 6.93 10.21 13.61 22.13
Cooling performance coefficient (EER) / 5.31  5.40  5.74  5.35  5.71  5.29 
Rated heating capacity KW 12.8 16.9 18.2 27.6 36.2 55.3
Rated input power for heating KW 2.98 3.93 4.16 6.45 8.42 12.86
Rated input current for heating A 15.1 19.8 8.66 12.3 17.56 26.4
Heating performance coefficient (COP) / 4.30  4.30  4.38  4.28  4.30  4.30 
Use side heat exchanger water flow M3/h 2.32 3.01 3.28 4.83 6.55 9.66
Heat source side heat exchanger water flow M3/h 1.32  1.71  1.87  2.75  3.72  5.49 
Ground source closed loop Rated cooling capacity KW 12.98  16.82  18.36  27.01  36.63  54.03 
Rated input power for cooling KW 2.59  3.30  3.40  5.36  6.80  10.83 
Rated input current for cooling A 12.33  16.66  7.23  11.39  14.48  23.05 
Cooling performance coefficient (EER) / 5.01  5.09  5.41  5.04  5.38  4.99 
Rated heating capacity KW 8.7 11.2 12.51  19.5 25.1 39.1
Rated input power for heating KW 3.21 4.15 4.15  6.62 8.42 13.27
Rated input current for heating A 15.34 19.7 9.43  15.05  19.14  30.16 
Heating performance coefficient (COP) / 2.71  2.70  3.01  2.95  2.98  2.95 
Use side heat exchanger water flow M3/h 2.23  2.89  3.16  4.65  6.30  9.29 
Heat source side heat exchanger water flow M3/h 2.79  3.62  3.95  5.81  7.87  11.62 
Power supply 220V/50Hz 380V/50Hz
Compressor Type Fully closed scroll type
Quantity PCS 1 1 1 1 2 2
Heat source side heat exchanger Type Shell & tube heat exchanger
Pipe size DN DN20 DN25 DN25 DN25 DN32 DN32
Use side heat exchanger Type Shell & tube heat exchanger
Pipe size DN DN20 DN25 DN25 DN25 DN32 DN32
Protections            
Refrigerant Type R410A
Quantity KG 2 2.6 2.9 3.3 2.9x2 3.3x2
Unit dimensions Length MM 810 810 810 810 1100 1100
Width MM 420 420 420 420 840 840
Height MM 590 590 590 590 800 800
Noise ≤DB(A) 40 40 40 50 55 60
Weight KG 115 118 120 180 190 700
Note:
1. Underground water type cooling standard condition: use side water input/output temperature 12ºC/7ºC; source side water input/output temperature 18ºC/29ºC.                                                                                                      Underground water type heating standard condition: use side water input/output temperature 40ºC/45ºC; source side water input/output temperature 15ºC/-a.
2. Ground source closed loop type cooling standard condition: use side water input/output temperature 12ºC/7ºC; source side water input/output temperature 25ºC/30ºC                                                                                             Ground source closed loop type heating standard condition: use side water input/output temperature 40ºC/45ºC ; source side water input/output temperature 5ºC/-a.
3. "-a " means the water flow under cooling standard condition.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

HEAT PUMP, WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, GROUND SOURCE HEAT PUMP, GEOTHERMAL HEAT PUMP.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier