Basic Info.

Model NO.
HW05P-E5
Work Environment
Common Heat Pump
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC
Product Name
Air Source Commercial Use Heat Pump (Kfxrs)
Compressor
Panasonnic
Refrigerant
R410A
Rated Heating Capacity
19kw
Rated Produce Hot Water Capacity
408L/H
Power Supply
3n 380V/50Hz
Transport Package
Safety Export Packing
Specification
standard
Trademark
CEN (Creative Power)
Origin
Zhejiang, China( Main Land)
HS Code
84189910
Production Capacity
5000 PCS Per Month

Product Description

  • CE approved

  • Long time of warranty

  • Machine casing: spray coating metal plate

  • Function: Production of hot water

  • Host machine color:  grey

  • Accessories: LCD controller, pressurized water tank(150L, 200L, 300L, 500L)

  • Safety protecting system:

  • 1)High and low pressure protection

  • 2)Anti-freeze protection

  • 3)High temperature protection

  • 4)Safety valve

  • 5)Overload protection

  • 6)Reverse phase

  • 7)Lack of phase

  • 8)Separation of water and electricity

    Refrigerant: R22/R410A/R417a

     A02H series (Air source heat pump water heater circulation type)                                                                                                                                          HW-150304

    HW03Ps-E3 HW05Ps-E5 HW03P-E3  HW05P-E5 HW07P-E5 HW10P-C24 HW14P-C24 HW20P-C48 HW24P-C48 HW30P-C48 HW36P-C48 HW48P-C96
    Rated heating capacity kW 12 19 12 19 25 35 50  75 85 105 125 165
    Rated input power kW 2.75  4.39  2.75  4.37  5.75  8.10  11.57  17.20  19.60  24.20  28.90  38.10 
    Rated input current A 14.05  23.10  5.17  8.34  10.77  15.00  23.86  31.80  37.00  46.10  53.50  72.30 
    Maximum input power kW 3.38  5.40  3.38  5.38  7.07  9.96  14.23  21.16  24.11  29.77  35.55  46.86 
    Maximum input current A 18.28  29.19  6.43  10.21  13.44  18.93  27.05  40.20  45.81  56.56  67.54  89.04 
    Performance coefficient(COP) / 4.36  4.33  4.36  4.35  4.35  4.33  4.32  4.36  4.34  4.34  4.33  4.33 
    Rated hot water output temp. ºC 55 
    Max. hot water output temp. ºC 60 
    Rated hot water produce capacity L/H 258 408 258 408 537 752.5 1075 1612.5 1827.5 2257.5 2687.5 3547.5
    Power supply 1N 220V/50Hz 3N 380V/50Hz
    Compressor Type Fully closed scroll type
    Start Mode Directly start
    Quantity Set 1 1 1 1 1 2 2 4 2 3 3 4
    Water side heat exchanger Type Shell & coil(tube) heat exchanger
    Water flow m3/h 2.1  3.3  2.1  3.3  4.3  6.0  8.6  12.9  14.6  18.1  21.5  28.4 
    Water Pressure Drop kPa ≤50 ≤55 ≤50 ≤55 ≤55 <60 <60 <65 <65 <65 <65 <65
    Pipe size DN DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN65 DN80
    Protections 1. High pressure and low pressure protection, 
    2. Anti-freezing protection, 
    3. High temperature protection, 
    4. Too big of the water temperature difference for outlet and inlet protection, 
    5. Overload protection, 
    6. Lack phase protection, 
    7. Reverse phase protection, etc.. 
    Refrigerant Throttle Type Electronic expansion valve
    Quantity kg 1.9 2.8 1.9 2.8 4.1 2.8×2 4.1×2 3.2×4 7.6×2 6.2×3 7.6×3 7.6×4
    Noise DB(A) ≤55 ≤63 ≤55 ≤63 ≤65 ≤65 ≤68 ≤70 ≤72 ≤73 ≤74 ≤78
    Dimension mm 700×680×
    875
    820×695×
    1060
    700×680×
    875
    820×695×
    1060
    820×695×
    1060
    1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1980 1000×2050×1980 2000×2050×1980
    Net Weight kg 100 160 100 160 190 310 400 605 650 835 840 1230
    Testing conditions: 
    1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC.
    2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. 
    The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us.
    The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

    Air Source Commercial Use Heat Pump 19kwAir Source Commercial Use Heat Pump 19kwAir Source Commercial Use Heat Pump 19kw


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier