Customization: | Available |
---|---|
Certification: | CCC, ISO9001, CE |
Working Medium: | R410A |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R410a refrigerant; |
* Stainless steel 304 for all fasteners, for side covers of evaporator; |
* Preservative oil for copper tubes and all important part of cabinet; |
* Chinese No.1 brand "Gimleo" Titanium tube heat exchanger; |
* Japan "Saginomiya" or "Sanhua" electronic expansion valve; |
* "Sanhua" 4-way valve; |
* LCD controller; |
* Delivery time: 20~25 days; |
* Payment term: T/T 30% in advance and T/T 70% before delivery; |
* Warranty time: 24 months after delivery. |
S02H series(Swimming pool heat pump) |
||||||||||||||||
SP2.5PS-H2 | SP03PS-E3 | SP05PS-E5 | SP03P-E3 | SP05P-E5 | SP07P-E5 | SP10P-C24 | SP14P-C24 | SP20P-C48 | SP24P-C48 | SP30P-C48 | SP36P-C96 | SP40P-C96 | SP48P-C96 | |||
Rated heating capacity | kW | 12 | 14 | 24 | 14 | 24 | 32 | 48 | 66 | 95 | 115 | 145 | 170 | 190 | 230 | |
Rated input power | kW | 2.11 | 2.45 | 4.14 | 2.37 | 4.06 | 5.69 | 8.14 | 11.57 | 16.10 | 19.49 | 25.11 | 29.31 | 32.76 | 39.65 | |
Rated input current | A | 10.82 | 12.56 | 21.23 | 4.55 | 7.80 | 10.92 | 15.63 | 22.21 | 30.91 | 37.42 | 48.21 | 56.28 | 62.90 | 76.13 | |
COP | / | 5.59 | 5.71 | 5.80 | 5.91 | 5.91 | 5.62 | 5.90 | 5.70 | 5.90 | 5.90 | 5.77 | 5.80 | 5.80 | 5.80 | |
*Heating capacity | kW | 9 | 12 | 20 | 12 | 20 | 25 | 40 | 52 | 80 | 95 | 120 | 145 | 160 | 190 | |
*Input power | kW | 1.80 | 2.30 | 3.88 | 2.33 | 3.80 | 4.87 | 7.62 | 9.98 | 15.36 | 18.20 | 22.81 | 27.83 | 30.48 | 36.19 | |
*Input current | A | 9.21 | 11.81 | 19.92 | 4.47 | 7.30 | 9.36 | 14.63 | 19.16 | 29.48 | 34.94 | 43.80 | 53.44 | 58.51 | 69.49 | |
*COP | / | 5.01 | 5.21 | 5.15 | 5.15 | 5.26 | 5.13 | 5.25 | 5.21 | 5.21 | 5.22 | 5.26 | 5.21 | 5.25 | 5.25 | |
Maximum input power | kW | 2.74 | 3.19 | 5.38 | 3.08 | 5.28 | 7.40 | 10.58 | 15.04 | 20.93 | 25.34 | 32.64 | 38.10 | 42.59 | 51.55 | |
Maxmum input current | A | 14.05 | 16.33 | 27.60 | 5.92 | 10.13 | 14.20 | 20.32 | 28.88 | 40.19 | 48.65 | 62.67 | 73.16 | 81.77 | 98.97 | |
Rated hot water output temperature' | ºC | 28 | ||||||||||||||
Maximum hot water output temperature | ºC | 35 | ||||||||||||||
Power supply | 1N 220V/50Hz | 3N 380V/50Hz | ||||||||||||||
Compressor | Type | Rotor type | Fully closed scroll type | |||||||||||||
Start mode | Directly start | |||||||||||||||
Quantity | Set | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 3 | 4 | 4 | |
Water side heat exchanger | Type | Titanium tube heat exchanger | ||||||||||||||
Water flow | M3/h | 5.07 | 6.02 | 10.32 | 6.02 | 10.32 | 13.76 | 20.64 | 28.38 | 40.85 | 49.45 | 62.35 | 73.10 | 81.70 | 98.90 | |
Water pressure drop | KPa | ≤50 | ≤70 | |||||||||||||
Pipe size | Φ | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ50 | Φ90 | Φ90 | Φ110 | Φ110 | Φ110 | |
Protections | 1. High pressure and low pressure protection, 2. Anti-freezing protection, 3. High temperature protection, 4. Too big of the water temperature difference for outlet and inlet protection, 5. Overload protection, 6. Lack phase protection, 7. Reverse phase protection, 8. Water flow protection etc. |
|||||||||||||||
Noise | DB(A) | ≤50 | ≤55 | ≤63 | ≤55 | ≤63 | ≤63 | ≤65 | ≤68 | ≤70 | ≤72 | ≤73 | ≤74 | ≤76 | ≤78 | |
Unit dimensions | mm | 1000×360× 630 |
700×700× 870 |
820×695× 1060 |
700×700× 870 |
820×695× 1060 |
820×695× 1060 |
1000×1000×1858 | 1000×1000×1858 | 1000×2050×1900 | 1000×2050×1900 | 1000×2050×1980 | 2000×2050×1980 | 2000×2050×1980 | 2000×2050×1980 | |
Weight | KG | 64 | 100 | 160 | 100 | 160 | 165 | 335 | 365 | 600 | 660 | 840 | 860 | 1225 | 1260 | |
Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC | ||||||||||||||||
2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC | ||||||||||||||||
The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us. | ||||||||||||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret. |