• Air Source Heat Pump Water Heater Circulation Type (HW020P-C48)
  • Air Source Heat Pump Water Heater Circulation Type (HW020P-C48)
  • Air Source Heat Pump Water Heater Circulation Type (HW020P-C48)

Air Source Heat Pump Water Heater Circulation Type (HW020P-C48)

Type: Heat Pump
Certification: CE, ISO
Structure: Vertical Type
Brand: Konnen
Principle: Recuperative Heat Exchanger
Structure Material: Metal Material
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Application
Cooler
Heat Transfer Surface
Plate Heat Exchanger
Transport Package
Carton Packaging with Plywood
Specification
CE
Trademark
CEN
Origin
Zhejiang, China
HS Code
8418991000
Production Capacity
3000units/Month

Product Description

                      Air to water heat pump 
Air Source Heat Pump Water Heater Circulation Type (HW020P-C48)

Air Source Heat Pump Water Heater Circulation Type (HW020P-C48)
A. High quality components:
1)Coplend flexible scroll compressor, strong and reliable, service life up to 15 years,
2)Emerson ALCO thermal expansion valve, with accurate and stable throttling performance, ensuring high COP

3)Al-Mg fan motor, and Nylon fan blades, low noise, durable, with big air volume.
4)Accurate design of the case for the fan to avoid virbration to reduce the noise largely.

B. Large heat exchanger, extracting more heat from the ambient air, with high COP and stable operation evenin low ambient temperature.

C. Special design and accurate workmanship forfixing the case with bolts and nuts, no damage to the case coating, avoiding corrosion and rust to the case.

D. Noise level in one meter ditance: 50-60dBA.

WE offer OEM service!

 
  CKFGRS-28 II CKFGRS-35 II CKFGRS-50 II CKFGRS-70 II CKFGRS-85 II
( CE02A08A ) ( CE02A10A ) ( CE02A14A ) ( CE02A20A ) ( CE02A24A )
Rated  cooling  capacity KW 21 30 40 55 68
Rated  heating  capacity KW 22 33 42 57 71
Rated  water  heating  capacity KW 28 35 50 70 85
Rated  input  power  for  cooling KW 7.4  10.5  14.1  19.3  23.9 
Rated  input  power  for  heating KW 7.5  11.2  14.3  19.4  24.2 
Rated  input  power  for  water  heating KW 7.4  9.3  13.3  18.6  22.6 
Rated  input  current  for  cooling A 13.9  19.8  26.4  36.4  45.0 
Rated  input  current  for  heating A 14.2  21.2  27.0  36.7  45.7 
Rated  input  current  for  water  heating A 14.1  17.6  25.1  35.2  42.7 
Maximum  power KW 9.2  11.5  16.5  23.1  28.0 
Maximum  current A 17.4  21.8  31.2  43.6  53.0 
Output  water  quantity L/H 602.0  752.5  1075.0  1505.0  1827.5 
Cooling  performance  coefficient  (EER) / 2.8  2.9  2.8  2.8  2.8 
Heating  performance  coefficient  (COP) / 2.9  3.0  2.9  2.9  2.9 
Hot  water  performance  coefficient  (COP) / 3.8  3.8  3.8  3.8  3.8 
Rated  hot  water  output  temperature   55 
Maximum    hot  water  output  temperature   60 
Power  supply 3N  380V/50HZ
Alternative  power  supply (1N  208-230V/60Hz);     (1N  220-240V/50Hz);     (3N  220-240V/50Hz)
(3N  208-230V/60Hz);     (3N  380-415V/50Hz);     (3N  440-460V/60Hz);     (3N  380V/60Hz)
Compressor Type Scroll  type
Start  mode Direct
Cooling/heating  side  heat  exchanger Type Plate  type  heat  exchanger Horizontal  type  shell  and  tube  heat  exchanger
Water  flow M 3 /h 3.612 5.16 6.88 9.46 11.696
Water  pressure  drop KPa 50 50 50 50 50
Water  pipe  size DN DN32 DN50
Pipe  connection Inner  thread Flange
Hot  water  side  heat  exchanger Type Vertical  type  shell  and  tube  heat  exchanger Horizontal  type  shell  and  tube  heat  exchanger
Water  flow M 3 /h 4.816 6.02 8.6 12.04 14.62
Water  pressure  drop KPa 50 50 50 50 50
Water  pipe  size DN DN32 DN50
Pipe  connection Inner  thread Flange
Protections 1. High  and  low  pressure  protection,       2. Anti-freeze  protection,                                                                                                                                                                                 3. High  temperature  protection,         4. Overload  protection,                                                                                                                             5. Reverse  of  phase  protection, lack  of  phase  protection, etc.
Refrigerant Type R410A
Throttle  mode Thermal  expansion  valve
Quantity(KG) 5.3× 2 5.9× 2 6.3× 2 8.3× 2 9.0× 2
Unit  dimensions Length MM 1460 1460 1460 2050 2050
Width MM 910 910 910 1100 1100
Height MM 1430 1430 1430 1935 1935
Noise ≤ DB ( A ) 65 65 65 67 67
Weight KG 315 340 380 650 650
Note:   1. Standard  cooling  working  condition:   dry  bulb  temperature  35   ,   use  side  water  input/output  temperature  12/7
2. Standard  heating  working  condition:   dry  bulb  temperature  7   ,   use  side  water  input/output  temperature  40/45
3. Standard  hot  water  heating  working  condition:   dry  bulb  temperature  20   ,   wet  bulb  15, use  side  initial  temperature  15   ,   end  water  temperature  55 
4. The  above  parameters  are  based  on  Refrigearnt  R410A,   for  parameters  based  on  other  refrigerant  please  contact  us.
The  above  parameters  may  have  some  differences  from  the  final  product  because  of  products  updating,   so  above  information  is  not  the  provision  of  any  business  contract.   Please  refer  to  final  product  label  when  buy,   or  refer  to  us  for  any  information.   Our  company  keeps  the  right  to  interpret.