Heat Source: Ground-source
Certification: CE
Transport Package: Safe Export Packing
Trademark: CEN
Origin: China
Samples:
US$ 598/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
W02H
HS Code
8418612090
Production Capacity
5000 Units/Month

Product Description

KONNEN WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, WITH COPELAND COMPRESSOR AND R410A REFRIGERANT:
* Panasonic compressor & R410a refrigerant or Copeland compressor & R410a refrigerant;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Schneider AC contactor and relay
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* KONNEN LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY 2017(HEAT PUMP + WATER TANK + CONTROLLER):
Ground Source Heat Pump
WHY US:
Ground Source Heat Pump
KONNEN NEW PROJECTS:
Ground Source Heat PumpKONNEN HEAT PUMPS FOR EXPORTING:
Ground Source Heat Pump

WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Ground Source Heat Pump
PRODUCT FEATURES:
Ground Source Heat Pump

PARAMETERS TABLE:
W02H series (water source heat pump water heater)     
Model CSFXRS-8I CSFXRS-12I CSFXRS-20I CSFXRS-12II  CSFXRS-20II  CSFXRS-28II CSFXRS-40II CSFXRS-55II CSFXRS-80II CSFXRS-95II CSFXRS-120II CSFXRS-145II CSFXRS-190II
Rated heating capacity KW 8 12 20 12 20 28 40 55 80 95 120 145 190
Rated power KW 1.64  2.41  4.02  2.41  3.91  5.58  7.98  11.07  16.26  19.11  24.44  29.47  39.09 
Rated current A 7.11  10.48  17.46  4.56  7.38  10.54  15.09  20.92  30.73  36.13  46.19  55.70  73.89 
Maximum power KW 2.21  3.25  5.42  3.14  5.08  7.25  10.38  14.39  21.14  24.85  31.77  38.31  50.82 
Maximum current A 10.52  15.49  25.82  6.12  9.90  14.14  20.24  28.05  41.22  48.46  61.96  74.71  99.10 
Performance coefficient COP 4.89  4.98  4.98  4.97  5.12  5.02  5.01  4.97  4.92  4.97  4.91  4.92  4.86 
Rated hot water yields L/H 172 258  430  258  430  602  860  1182  1720  2043  2580  3118  4085 
Setting water temperature ºC 50ºC(default)  28-60ºC(adjustable)
Power supply 1N 220V/50Hz                                                      (Special power supply for option) 3N 380V/50Hz(Special power supply for option)
Compressor Type Hermetic Rotor type Hermetic scroll type
Start mode Direct(Soft start for option)
Application side heat exchanger Type Shell & tube heat exchanger(Tube in tube heat exchanger or Plate type heat exchanger for option) Shell & tube heat exchanger
Water flow M3/h 1.4 2.1  3.4  2.1  3.4  4.8  6.9  9.4  13.8  16.3  20.6  24.9  32.7 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70
Pipe connection DN DN20 DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN65 DN65
Pipe type Inner thread Flange
Heat source side heat exchanger Type Shell & tube heat exchanger
Water flow M3/h 1.1 1.6  2.7  1.6  2.7  3.8  5.4  7.3  10.7  12.7  16.1  19.4  25.5 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70
Pipe size DN DN20 DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN65 DN65
Connection type Inner thread Flange
Protections 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.
Refrigerant  Type R410A
Quantity(KG) 1.6 1.9 2.8 1.9 2.8 3 2.8x2 6.5x2 8x2 8.7x2 8x3 8.7x3 8.7x4
Noise DB(A) ≤52 ≤53 ≤55 ≤55 ≤55 ≤58 ≤58 ≤62 ≤65 ≤65 ≤70 ≤75 ≤75
Dimension mm 810x420x590 840x800x1430 1800x1150x1050
Net weight KG 55 68 95 65 95 135 195 320 795 885 985 1180 1210
Gross weight KG 65 78 105 75 105 145 215 340 830 920 1020 1215 1245
Note: 1. Hot water heating standard condition: use side initial water temperature 15ºC, end water temperature 55ºC;  heat source side water input temperature 15ºC.  
          2. The above parameters are based on refrigerant R410A, for parameters based on other refrigerant please contact us.
          3. The above parameters may have some differences from the final product because of products updating, please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

HEAT PUMP, WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, GROUND SOURCE HEAT PUMP, GEOTHERMAL HEAT PUMP.Ground Source Heat Pump
(Water Source Heat Pump)

1. High Reliability
Using famous parts, and as the temperature of the original source is stable, the water/ground source heat pump works more reliable and stable, guaranteeing the high efficiency and economy. Without problem of defrosting in winter.

2. Different functions available
It could be used for cooling, heating or tap hot water for daily life, or combines two/three of these functions.

Wä Rmepumpe, wä Rme pumpe, pompa ciepa, pompy ciepa, bomba calor, pompe chaleur, pompa di calore, α ν τ λ α θ ρ μ τ η τ α , varmepumpe, varmepumpen, varme pumpe, warmtepomp, warmte pomp, tepelné Erpadlo, hszivattyú , hszivattyú S, s pompas, toplinska pumpa, siltumsknis, toplinska pumpa, toplinska crpka, ilumos siurblys, soojuspump, bomba calor
3. High Efficiency for Heat Recovery
Using the latest high technology, following the law of conservation, when the unit is cooling, the heat recovers to produce the hot water (for example, in summer, it provides the free hot water by heat recovery). The unit is with higher efficiency and more energy saving.

4. Less Cost
The working condition is reliable, so the system is simple and less components. It runs easily and reliably, and maintenance cost is less.

5. Environment friendly
Use R410A refrigerant, the ratio of ozonosphere damage is zero, environment friendly, green product, meet the countries' environmental protection demand.



Heat Pump, Air Source Heat Pump, Air to Water Heat Pump, Home Use Heat Pump, Commercial Use Heat Pump, Water Source Heat Pump, Water to Water Heat Pump, Ground Source Heat Pump, Geothermal Heat Pump, Domestic Use Heat Pump, Home Use Heat Pump, EVI Heat Pump, EVI System Air Source Heat Pump, Made In China, Direct Air Source Heat Pump, Water Heater Heat Pump, Central Heating Heat Pump, Floor Warming Heat Pump.
                                                                    Models     
Parameter
CSFXRS-4 I CSFXRS-8 I CSFXRS-12 II CSFXRS-20 II CSFXRS-40 II CSFXRS-50 II CSFXRS-60 II
Hot  Water  Heating  Capacity kW 4 8 12 20 40 50 60
input  power kW 0.82 1.64 2.5 4.1 8.3 10.2 12.5
input  current A 4.3 8.6 4.5 7.4 14.9 19.2 23.2
rated  hot  water  outlet  temperature   55
maximum  hot  water  outlet  temperature   60
Power  Supply 220V/50Hz 380V/50Hz
compressor type rotor  type scroll  type
Start  Method Direct  Start
quantity pc 1 1 1 1 2 2 2
source  side  heat  exchanger type coaxial  heat  exchanger/plate  type  heat  exchanger shell  and  tube  heat  exchanger
water  flow m³ /h 0.55 1.1 1.6 2.7 5.5 6.9 8.3
Water kPa < 20 < 38 < 40
pipe  size mm DN20 DN20 DN20 DN25 DN32 DN32 DN50
application  side  heat  exchanger type shell  and  tube  heat  exchanger/coaxial  heat  exchanger shell  and  tube  heat  exchanger
water  flow m³ /h 0.69 1.4 2.1 3.4 6.9 8.6 10.3
Water  pipe  size kPa < 20 < 35 < 40
mm DN20 DN20 DN20 DN25 DN32 DN32 DN50
Protection high  pressure  and  low  pressure  protection,   anti-freezing  protection,   high  temperature
protection,   safety  valve,   overload  protection,   lack  phase  protection,   reverse  phase
protection,   water  flow  protection  ect.
refrigerant type R22/R410A/R407C/R134A
Throttle  Type thermostatic  expansion  valve
quantity kg 0.8 1.1 1.9 2.8 2.7× 2 3.4× 2 4.5× 2
Noise dB ( A ) 32 35 38 42 62 62 62
Weight kg 40 45 69 93 340 440 570
1, High efficieny, stable operation, with large heat exchangers, extracting more heat from underground, lake, or river.
2. Save 80% ofthecost of traditional boilers.
3, Quiet: The system design is optimized to reduce vibration, with noise insulation inside.
4, Anti-corrosion: Durable coating with special case design by using stainless steel bolts and nuts, no rust.
5. Easy installation, low maintenance cost.
6. Using high quality Coplend flexible scroll compressor, strong and reliable, Emerson ALCO thermal expansion valve, stainless steel plate heat exchanger. Long service life up to 15 years.
Unit Model SFXRS-17.5II
Rated heating capacity (KW) 17
Heating input power (KW) 4.4
Rated cooling capacity (KW)  16
Cooling input power (KW) 4.3
Rated produce hot water quantity   (L/H) 370
Rated outlet hot water temperature (  º C ) 55----60
Cold return water temperature ( º C ) 7---12
Refrigerant charging quantity ( kg ) 3
Electrical source 380V ~ 50Hz
Dimensions   Length   (mm) 810
Width   (mm) 810
Height (mm) 900
Unit wight ( Kg ) 160
Noise     dB(A) ≤ 54
Unit control system Microcomputer central processor ( line control )
Protection   function High pressure protection, low pressure protection, overload protection
Applicable environment   temperature range ( º C ) -50