KONNEN WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, WITH COPELAND COMPRESSOR AND R410A REFRIGERANT:
* Panasonic compressor & R410a refrigerant or Copeland compressor & R410a refrigerant; |
* Preservative oil for copper tubes and all important part of cabinet; |
* Chinese No.1 brand "ND" shell & tube heat exchanger; |
* Schneider AC contactor and relay |
* Japan "Saginomiya" or "Sanhua" electronic expansion valve; |
* KONNEN LCD controller; |
* Delivery time: 20~25 days; |
* Payment term: T/T 30% in advance and T/T 70% before delivery; |
* Warranty time: 24 months after delivery. |
WE SUPPLY OEM SERVICE!
KONNEN NEW FACTORY 2017(HEAT PUMP + WATER TANK + CONTROLLER):
WHY US:
KONNEN NEW PROJECTS:
KONNEN HEAT PUMPS FOR EXPORTING:
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
PRODUCT FEATURES:
PARAMETERS TABLE:
W02H series (water source heat pump water heater) |
|
Model |
CSFXRS-8I |
CSFXRS-12I |
CSFXRS-20I |
CSFXRS-12II |
CSFXRS-20II |
CSFXRS-28II |
CSFXRS-40II |
CSFXRS-55II |
CSFXRS-80II |
CSFXRS-95II |
CSFXRS-120II |
CSFXRS-145II |
CSFXRS-190II |
Rated heating capacity |
KW |
8 |
12 |
20 |
12 |
20 |
28 |
40 |
55 |
80 |
95 |
120 |
145 |
190 |
Rated power |
KW |
1.64 |
2.41 |
4.02 |
2.41 |
3.91 |
5.58 |
7.98 |
11.07 |
16.26 |
19.11 |
24.44 |
29.47 |
39.09 |
Rated current |
A |
7.11 |
10.48 |
17.46 |
4.56 |
7.38 |
10.54 |
15.09 |
20.92 |
30.73 |
36.13 |
46.19 |
55.70 |
73.89 |
Maximum power |
KW |
2.21 |
3.25 |
5.42 |
3.14 |
5.08 |
7.25 |
10.38 |
14.39 |
21.14 |
24.85 |
31.77 |
38.31 |
50.82 |
Maximum current |
A |
10.52 |
15.49 |
25.82 |
6.12 |
9.90 |
14.14 |
20.24 |
28.05 |
41.22 |
48.46 |
61.96 |
74.71 |
99.10 |
Performance coefficient |
COP |
4.89 |
4.98 |
4.98 |
4.97 |
5.12 |
5.02 |
5.01 |
4.97 |
4.92 |
4.97 |
4.91 |
4.92 |
4.86 |
Rated hot water yields |
L/H |
172 |
258 |
430 |
258 |
430 |
602 |
860 |
1182 |
1720 |
2043 |
2580 |
3118 |
4085 |
Setting water temperature |
ºC |
50ºC(default) 28-60ºC(adjustable) |
Power supply |
1N 220V/50Hz (Special power supply for option) |
3N 380V/50Hz(Special power supply for option) |
Compressor |
Type |
Hermetic Rotor type |
Hermetic scroll type |
Start mode |
Direct(Soft start for option) |
Application side heat exchanger |
Type |
Shell & tube heat exchanger(Tube in tube heat exchanger or Plate type heat exchanger for option) |
Shell & tube heat exchanger |
Water flow |
M3/h |
1.4 |
2.1 |
3.4 |
2.1 |
3.4 |
4.8 |
6.9 |
9.4 |
13.8 |
16.3 |
20.6 |
24.9 |
32.7 |
Water pressure drop |
KPa |
≤50 |
≤50 |
≤50 |
≤50 |
≤50 |
≤50 |
≤50 |
≤60 |
≤60 |
≤70 |
≤70 |
≤70 |
≤70 |
Pipe connection |
DN |
DN20 |
DN20 |
DN25 |
DN20 |
DN25 |
DN25 |
DN32 |
DN50 |
DN50 |
DN50 |
DN65 |
DN65 |
DN65 |
Pipe type |
Inner thread |
Flange |
Heat source side heat exchanger |
Type |
Shell & tube heat exchanger |
Water flow |
M3/h |
1.1 |
1.6 |
2.7 |
1.6 |
2.7 |
3.8 |
5.4 |
7.3 |
10.7 |
12.7 |
16.1 |
19.4 |
25.5 |
Water pressure drop |
KPa |
≤50 |
≤50 |
≤50 |
≤50 |
≤50 |
≤50 |
≤50 |
≤60 |
≤60 |
≤70 |
≤70 |
≤70 |
≤70 |
Pipe size |
DN |
DN20 |
DN20 |
DN25 |
DN20 |
DN25 |
DN25 |
DN32 |
DN50 |
DN50 |
DN50 |
DN65 |
DN65 |
DN65 |
Connection type |
Inner thread |
Flange |
Protections |
1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc. |
Refrigerant |
Type |
R410A |
Quantity(KG) |
1.6 |
1.9 |
2.8 |
1.9 |
2.8 |
3 |
2.8x2 |
6.5x2 |
8x2 |
8.7x2 |
8x3 |
8.7x3 |
8.7x4 |
Noise |
DB(A) |
≤52 |
≤53 |
≤55 |
≤55 |
≤55 |
≤58 |
≤58 |
≤62 |
≤65 |
≤65 |
≤70 |
≤75 |
≤75 |
Dimension |
mm |
810x420x590 |
840x800x1430 |
1800x1150x1050 |
Net weight |
KG |
55 |
68 |
95 |
65 |
95 |
135 |
195 |
320 |
795 |
885 |
985 |
1180 |
1210 |
Gross weight |
KG |
65 |
78 |
105 |
75 |
105 |
145 |
215 |
340 |
830 |
920 |
1020 |
1215 |
1245 |
Note: 1. Hot water heating standard condition: use side initial water temperature 15ºC, end water temperature 55ºC; heat source side water input temperature 15ºC. |
2. The above parameters are based on refrigerant R410A, for parameters based on other refrigerant please contact us. |
3. The above parameters may have some differences from the final product because of products updating, please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret. |
HEAT PUMP, WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, GROUND SOURCE HEAT PUMP, GEOTHERMAL HEAT PUMP.Ground Source Heat Pump
(Water Source Heat Pump)
1. High Reliability
Using famous parts, and as the temperature of the original source is stable, the water/ground source heat pump works more reliable and stable, guaranteeing the high efficiency and economy. Without problem of defrosting in winter.
2. Different functions available
It could be used for cooling, heating or tap hot water for daily life, or combines two/three of these functions.
Wä Rmepumpe, wä Rme pumpe, pompa ciepa, pompy ciepa, bomba calor, pompe chaleur, pompa di calore, α ν τ λ α θ ρ μ τ η τ α , varmepumpe, varmepumpen, varme pumpe, warmtepomp, warmte pomp, tepelné Erpadlo, hszivattyú , hszivattyú S, s pompas, toplinska pumpa, siltumsknis, toplinska pumpa, toplinska crpka, ilumos siurblys, soojuspump, bomba calor
3. High Efficiency for Heat Recovery
Using the latest high technology, following the law of conservation, when the unit is cooling, the heat recovers to produce the hot water (for example, in summer, it provides the free hot water by heat recovery). The unit is with higher efficiency and more energy saving.
4. Less Cost
The working condition is reliable, so the system is simple and less components. It runs easily and reliably, and maintenance cost is less.
5. Environment friendly
Use R410A refrigerant, the ratio of ozonosphere damage is zero, environment friendly, green product, meet the countries' environmental protection demand.
Heat Pump, Air Source Heat Pump, Air to Water Heat Pump, Home Use Heat Pump, Commercial Use Heat Pump, Water Source Heat Pump, Water to Water Heat Pump, Ground Source Heat Pump, Geothermal Heat Pump, Domestic Use Heat Pump, Home Use Heat Pump, EVI Heat Pump, EVI System Air Source Heat Pump, Made In China, Direct Air Source Heat Pump, Water Heater Heat Pump, Central Heating Heat Pump, Floor Warming Heat Pump.
Models
Parameter |
CSFXRS-4 I |
CSFXRS-8 I |
CSFXRS-12 II |
CSFXRS-20 II |
CSFXRS-40 II |
CSFXRS-50 II |
CSFXRS-60 II |
Hot Water Heating Capacity |
kW |
4 |
8 |
12 |
20 |
40 |
50 |
60 |
input power |
kW |
0.82 |
1.64 |
2.5 |
4.1 |
8.3 |
10.2 |
12.5 |
input current |
A |
4.3 |
8.6 |
4.5 |
7.4 |
14.9 |
19.2 |
23.2 |
rated hot water outlet temperature |
|
55 |
maximum hot water outlet temperature |
|
60 |
Power Supply |
220V/50Hz |
380V/50Hz |
compressor |
type |
rotor type |
scroll type |
Start Method |
Direct Start |
quantity |
pc |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
source side heat exchanger |
type |
coaxial heat exchanger/plate type heat exchanger |
shell and tube heat exchanger |
water flow |
m³ /h |
0.55 |
1.1 |
1.6 |
2.7 |
5.5 |
6.9 |
8.3 |
Water |
kPa |
< 20 |
< 38 |
< 40 |
pipe size |
mm |
DN20 |
DN20 |
DN20 |
DN25 |
DN32 |
DN32 |
DN50 |
application side heat exchanger |
type |
shell and tube heat exchanger/coaxial heat exchanger |
shell and tube heat exchanger |
water flow |
m³ /h |
0.69 |
1.4 |
2.1 |
3.4 |
6.9 |
8.6 |
10.3 |
Water pipe size |
kPa |
< 20 |
< 35 |
< 40 |
mm |
DN20 |
DN20 |
DN20 |
DN25 |
DN32 |
DN32 |
DN50 |
Protection |
high pressure and low pressure protection, anti-freezing protection, high temperature |
protection, safety valve, overload protection, lack phase protection, reverse phase |
protection, water flow protection ect. |
refrigerant |
type |
R22/R410A/R407C/R134A |
Throttle Type |
thermostatic expansion valve |
quantity |
kg |
0.8 |
1.1 |
1.9 |
2.8 |
2.7× 2 |
3.4× 2 |
4.5× 2 |
Noise |
dB ( A ) |
32 |
35 |
38 |
42 |
62 |
62 |
62 |
Weight |
kg |
40 |
45 |
69 |
93 |
340 |
440 |
570 |