Water Source Heat Pump for Max. 80 Deg C Hot Water Output

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 60~80 Deg C
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Water Source Heat Pump for Max. 80 Deg C Hot Water Output
  • Water Source Heat Pump for Max. 80 Deg C Hot Water Output
Find Similar Products

Basic Info.

Model NO.
W07P-W5
Work Environment
Common Heat Pump
Heat Source
Ground-source
Heating Type
Circulating Heat
Application
Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, RoHS, SASO
Product Name
Ground Source Heat Pump with 12kw Heating Capacity
Rated Hot Water Outlet Temperature
70
Maximum Hot Water Outlet Temperature
80
Refrigerant
R134A
Capacity
19kw
Transport Package
Plywood Case with Pallet
Specification
CE
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
50 Units/Day

Product Description

KONNEN HIGH TEMPERATURE WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, WITH PANASONIC OR COPELAND COMPRESSOR AND R134A REFRIGERANT, MAX. WATER OUTPUT TEMPERATURE 80 DEG C:
* Panasonic compressor & R134a refrigerant or Copeland compressor & R134a refrigerant;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Schneider AC contactor and relay
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* KONNEN LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY 2017(HEAT PUMP + WATER TANK + CONTROLLER):

Water Source Heat Pump for Max. 80 Deg C Hot Water Output
WHY US:
Water Source Heat Pump for Max. 80 Deg C Hot Water Output
KONNEN NEW PROJECTS:
Water Source Heat Pump for Max. 80 Deg C Hot Water OutputKONNEN HEAT PUMPS FOR EXPORTING:
Water Source Heat Pump for Max. 80 Deg C Hot Water Output

WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Water Source Heat Pump for Max. 80 Deg C Hot Water Output
PRODUCT FEATURES:
Water Source Heat Pump for Max. 80 Deg C Hot Water Output

PARAMETERS TABLE:

HEAT PUMP, WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, GROUND SOURCE HEAT PUMP, GEOTHERMAL HEAT PUMP.
W03H series (High temperature Water source heat pump water heater)                                   
Model W03Ps-W5 W05Ps-W5 W03P-W5 W05P-W5 W07P-W5 W10P-W10 W14P-W10 W18P-W20 W24P-W20 W30P-W20 W36P-W40 W48P-W40
Rated heating capacity KW 8.5 14 8.5 14 19 28 40 50 66 84 100 132
Rated power KW 1.91  3.10  1.90  3.07  4.21  6.19  8.97  11.29  14.83  18.96  22.42  29.86 
Rated current A 8.36  13.61  3.57  5.77  7.92  11.65  16.86  21.22  27.88  35.65  42.15  56.14 
Maximum power KW 2.44  3.97  2.43  3.93  5.39  7.93  11.48  14.45  18.98  24.27  28.70  38.23 
Maximum current A 11.35  18.48  4.60  7.43  10.19  14.99  21.70  27.30  35.88  45.87  54.24  72.25 
Performance coefficient COP 4.46  4.51  4.47  4.56  4.51  4.52  4.46  4.43  4.45  4.43  4.46  4.42 
Rated hot water yields t40 L/H 183  301  183  301  409  602  860  1075  1419  1806  2150  2838 
t60 L/H 122  201  122  201  272  401  573  717  946  1204  1433  1892 
Setting water temperature ºC 70ºC(default)  28-80ºC(adjustable)
Power supply 1N 220V/50Hz                                                      (Special power supply for option) 3N 380V/50Hz(Special power supply for option)
Compressor Type Hermetic scroll type
Quantity Unit 1 1 1 1 1 2 2 2 2 3 3 4
Start mode Direct(Soft start for option)
Application side heat exchanger Type Shell & tube heat exchanger
(Tube in tube heat exchanger or Plate type heat exchanger for option)
Shell & tube heat exchanger
Water flow M3/h 1.5  2.4  1.5  2.4  3.3  4.8  6.9  8.6  11.4  14.4  17.2  22.7 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70
Pipe connection DN DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN65 DN65
Pipe type Inner thread Flange
Heat source side heat exchanger Type Shell & tube heat exchanger
Water flow M3/h 1.1  1.9  1.1  1.9  2.5  3.8  5.4  6.7  8.8  11.3  13.4  17.7 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70
Pipe size DN DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN65 DN65
Connection type Inner thread Flange
Protections 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.
Refrigerant  Type R134A
Quantity(KG) 2.2 3.3 2.2 3.3 4.2 3.3x2 6.5x2 8x2 8.8x2 8.2x3 8.8x3 8.8x4
Noise DB(A) ≤53 ≤55 ≤55 ≤55 ≤58 ≤58 ≤62 65 ≤65 ≤70 ≤75 ≤75
Dimension mm 956x556x680 840x1100x800 1795x1116x1050 2000x1200
x1000
2665x1110
x1201
Net weight KG 68 95 65 95 135 195 320 480 885 985 1180 1210
Gross weight KG 78 105 75 105 145 215 340 515 920 1020 1215 1245
Note: 1. Hot water heating standard condition: use side initial water temperature 15ºCend water temperature 55ºC;  heat source side water input temperature 15ºC.  
    2. The above parameters are based on refrigerant R134A, for parameters based on other refrigerant please contact us.
   3.  The above parameters may have some differences from the final product because of products updating, please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.