• Commercial Use Air Source Heat Pump Water Heater for Hot Water
  • Commercial Use Air Source Heat Pump Water Heater for Hot Water
  • Commercial Use Air Source Heat Pump Water Heater for Hot Water
  • Commercial Use Air Source Heat Pump Water Heater for Hot Water
  • Commercial Use Air Source Heat Pump Water Heater for Hot Water
  • Commercial Use Air Source Heat Pump Water Heater for Hot Water

Commercial Use Air Source Heat Pump Water Heater for Hot Water

Energy Efficiency Grade: One
Heat Temperature: 40-60°c
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family
Samples:
US$ 1050/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
HW03P-HW60P
Certification
CE, ISO9001, CCC, SASO, TUV
Rated Heating Capacity
19kw
Rated Outlet Hot Water Quantity (L/H)
R410A/R417A/R134A
Transport Package
Safe Export Packing, with Pallet
Specification
CE
Trademark
KONNEN
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
1000 Units/Month

Product Description

KONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Commercial Use Air Source Heat Pump Water Heater for Hot Water
WHY US:
Commercial Use Air Source Heat Pump Water Heater for Hot Water
KONNEN NEW PROJECTS:
Commercial Use Air Source Heat Pump Water Heater for Hot Water
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Commercial Use Air Source Heat Pump Water Heater for Hot Water
KONNEN HEAT PUMPS LOADING:
Commercial Use Air Source Heat Pump Water Heater for Hot Water
PARAMETERS TABLE:
HotSpring series (Air source heat pump water heater circulation type)                                                                                                                                                      
  HW03Ps-E3 HW05Ps-E5 HW03P-E3 HW05P-E5 HW07P-E5 HW10P-E10 HW14P-E10 HW20P-E20 HW24P-E20 HW30P-E20 HW40P-C96 HW48P-C96 HW60P-C96
Rated heating capacity kW 11.8 18.7 11.9 18.8 24.5 34.7 49.6  73.8 84.5 103.8 137.5 164.7 204.8
Rated input power kW 2.83  4.44  2.85  4.45  5.86  8.16  11.95  17.66  20.02  24.95  33.25  39.17  48.89 
Rated input current A 15.13  23.74  5.41  8.45  11.53  15.89  20.91  35.78  38.24  48.38  63.15  74.39  92.86 
Maximum input power kW 3.84  7.32  3.82  7.31  9.68  11.47  17.38  27.20  31.28  39.11  42.15  49.58  66.15 
Maximum input current A 19.50  38.80  6.41  12.15  18.42  22.36  29.53  51.23  59.15  73.96  80.62  94.34  126.11 
Performance coefficient(COP) / 4.17  4.21  4.17  4.22  4.18  4.25  4.15  4.18  4.22  4.16  4.14  4.20  4.19 
Rated hot water output temp. ºC 55 
Max. hot water output temp. ºC 60 
Rated hot water produce capacity L/H 253 401 253 401 525 744 1063 1582 1812 2226 2949 3532 4392
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Hermetic scroll type
Start Mode Directly start
Quantity Set 1 1 1 1 1 2 2 4 4 4 4 4 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 2.1  3.3  2.1  3.3  4.1  6.0  8.6  12.9  14.6  18.1  23.7  28.4  35.2 
Water Pressure Drop kPa ≤50 ≤55 ≤50 ≤55 ≤55 <60 <70 <70 <72 <72 <75 <75 <75
Pipe size DN DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN80 DN80 DN80
Protections 1. High pressure and low pressure protection,
2. Anti-freezing protection,
3. High temperature protection,
4. Too big of the water temperature difference for outlet and inlet protection,
5. Overload protection,
6. Lack phase protection,
7. Reverse phase protection, etc..
Refrigerant Throttle Type Electronic expansion valve
Quantity kg 1.9 2.6 1.9 2.6 4 2.6×2 4.0×2 2.6×4 3.2×4 4.0×4 6.0×4 7.2×4 9.2x4
Noise DB(A) ≤55 ≤63 ≤55 ≤63 ≤68 ≤68 ≤68 ≤69 ≤69 ≤70 ≤74 ≤74 ≤75
Dimension mm 700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1060
1502×750×
1060
1502×750×
1060
1995×1165×1105 1995×1165×1105 1995×1165×1105 2000×2050×1980 2000×2050×1980 2000×2050×1980
Net Weight kg 110 160 110 160 190 255 400 600 725 855 1050 1230 1620
Testing conditions:
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC.
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us.