Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE

Product Details
Customization: Available
Certification: SASO, CCC, ISO9001, CE, TUV
Working Medium: R410A
Still deciding? Get samples of US$ 1100/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
  • Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
  • Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
  • Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
  • Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
Find Similar Products

Basic Info.

Model NO.
RF8I/bdm---RF27I/bdm
Heat Source Type
Air Source Heat Pump
Product Name
Air to Water Heat Pump Water Heater
Rated Outlet Hot Water Temperature
55 Degree
Maximum Outlet Hot Water Temperature
56 Degree
Compressor
Gmcc
Refrigerant
R410A
Usage
Water Heater
Control Type
Digital
Display Type
LCD
Material
Colored Steel Casing
Working Range
-30--43 Degree
Power Supplier
220V/1/50Hz
Heating Capacity (Kw)
8.8kw-17kw
Power Input (Kw)
2.55-4.91
Cooling Capacity (Kw)
8-12
Cooling Input(Kw)
3.2-4.8
Transport Package
Safe Export Packing
Specification
RF8I/bd--RF16I/bd
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
2500units/Month

Product Description



KONNEN DC INVERTER AIR SOURCE HEAT PUMP, FOR COOLING +HEATING:
* Delivery time:about 30days after received deposit;
* Payment:T/T 30% prepaid ,then pay for the balance before delivery;
*Package:ply-wood cases;
* Warrenty:18month;

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CEKONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
WHY US:
Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
KONNEN NEW PROJECTS:
Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
KONNEN HEAT PUMPS LOADING:
Evi Air to Water/Air Source DC Inveter Heat Pump for Heating /Cooling /Hot Water with CE
PARAMETERS TABLE:
POLESTAR series DC INVERTER MONOBLOCK TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER
Model RF6I/bd RF8I/bd RF12I/bd RF16I/bd RF20I/bd RF20II/bd
Power Supply V/Ph/Hz 220~240/1/50 380/3/50
Rated Condition 7ºC Heating Capacity (KW) 6.2 8.5 15 18 20 20
Power Input (KW) 1.88 2.66 4.36 5.21 5.88 5.88
COP 3.3 3.2 3.44 3.45 3.4 3.4
Nominal Condition -12ºC Heating Capacity (KW) 5 5.50 10.50 12.13 14.5 14.5
Power Input (KW) 2.17 2.33 4.40 5.05 6.01 6.02
COP 2.3 2.36 2.40 2.40 2.41 2.41
Low Temp. Condition -20ºC Heating Capacity (KW) 4.1 4.70 9.21 10.52 12.5 12.5
Power Input (KW) 2.16 2.47 4.56 5.18 6.25 6.25
COP 1.9 1.90 2.02 2.03 2 2
Low Temp. Condition -25ºC
/Water output temp. 41ºC
Heating Capacity (KW) 3.2 3.55 6.82 8.76 10.35 10.35
Power Input (KW) 2.1 2.20 4.21 5.03 6.02 6.02
COP 1.52 1.61 1.62 1.74 1.72 1.72
Low Temp. Condition -25ºC
/Water output temp. 50ºC
Heating Capacity (KW) 2.96 3.19 6.14 8.08 9.59 9.58
Power Input (KW) 2.17 2.28 4.23 5.69 6.81 6.81
COP 1.36 1.40 1.42 1.42 1.41 1.41
Rated Cooling Condition Cooling capacity (KW) 4.77 7.00 11.50 12.00 15.00 15.00
Power input (KW) 1.83 2.64 4.34 4.61 5.75 5.74
EER 2.6 2.65 2.65 2.60 2.61 2.61
Max. power input (KW) 2.7 4.4 5.2 6.6 7.1 8.5
Max. current Without E-heater (A) 12.5 20 23.7 30 32.5 15.5
Max. Water Output Temp. Under Ambient Temp. -25ºC 58 58 58 58 58 58
Water resistance (kPa) 30 35 38 43 54 50
Noise Level dB(A) 56.5 59.5 61.5 61.5 62 63
Refrigerant R410A R410A R410A R410A R410A R410A
Water Flow 0.86m³/h 0.95 m³/h 1.98 m³/h 2.06 m³/h 2.5m³/h 2.5m³/h
Pipe Size DN20 DN25
Dimensions(mm) 795*300*550 920*365*710 940*393*1373
Net Weight 45kg 60Kg 130kg 130kg 140kg 145kg
Testing Condition:
- Rated condition: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C


 
DC INVERTER SPLIT TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER
Model RF27I/bdm
Rated Heating Heating capacity kW 27.00
Power input kW 8.04
COP W/W 3.36
Nominal Heating Heating capacity kW 19.50
Power input kW 8.26
COP W/W 2.36
IPLV(H) W/W 2.80
Low Temp. Heating Heating capacity kW 16.50
Power input kW 8.46
COP W/W 1.95
Rated Cooling Cooling capacity kW 19.5
Power input kW 7.77
EER W/W 2.51
Power Supply V/Ph/Hz 380/3/50
Max. Power Input
(With E-Heater)
kW 10.5KW+3KW
Max. Current Input
(With E-Heater)
A 20A+13.6A
Max. Water Temp.
(Without E-Heater)
ºC 58
Working Range
(Ambient temp.)
ºC -30 to 43
Refrigeration Circulation Refrigerant Type R410A
Qty./Kg 4600g
Compressor Qty. 2
Type DC INVERTER DOUBLE ROTOR
Brand GMCC
Evaporator Type High efficiency hydrophilic aluminum foil fin heat exchanger
EEV Brand SANHUA
Fan Motor Qty. 2
Power
Input(W)
2*150
Fan Blades Size mm Φ525*135
Liquid valve size inch(mm) 3/8"(9.52)
Gas valve size inch(mm) 5/8"(15.88)
Water system Condenser Type Tube in tube heat exchanger
Water Pump Brand XINHU
Model GPD25-12S
Water Flow m3/h 3.35 
Water Drop kpa 65
Air Vent Valve / Standard
Pressure Release Valve / Standard
Pressure
value
3kgs
E-Heater kW 3
Buffer Tank L 5
Water
Inlet/Outlet Pipe
inch(mm) 1/2" ,3/4" male
Net Dimensions indoor Unit
(L*W*H)
mm 760x510x330
Outdoor Unit
(L*W*H)
mm 1118*425*1556
Package Size indoor Unit
(L*W*H)
mm 795x562x373
Outdoor Unit
(L*W*H)
mm 1240x670x1750
N.W. Indoor Unit kg 140
Outdoor Unit kg  
G.W. Indoor Unit kg 48
Outdoor Unit kg  
Noise Level Indoor Unit dB(A) ≤63
Outdoor Unit dB(A)  
Product Photo  
Product implementation standards: GB/T 25127.2-2010 GB/T 18430.2-2016 Testing Condition:
- Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
- Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier