W02F Series Ground source heat pump for Cooling/Heating |
Model |
CRS13/S |
CRS13/S |
CRS19/S |
CRS26/S |
CRS38/S |
CRS49/S |
CRS76/S |
CRS91/S |
CRS114/S |
(CS02W035S) |
(CS02W035S) |
(CS02W050S) |
(CS02W070S) |
(CS02W100S) |
(CS02W140S) |
(CS02W200S) |
(CS02W240S) |
(CS02W300S) |
Underground water type |
Rated cooling capacity |
KW |
13.5 |
13.5 |
19.1 |
26.1 |
38.1 |
52 |
76.10 |
91.50 |
114.20 |
Rated input power for cooling |
KW |
2.54 |
2.54 |
3.33 |
4.86 |
6.67 |
9.8 |
13.70 |
16.78 |
21.05 |
Rated input current for cooling |
A |
12.81 |
4.7 |
6.93 |
9.72 |
13.61 |
19.5 |
27.22 |
32.66 |
40.83 |
Cooling performance coefficient (EER) |
/ |
5.31 |
5.31 |
5.74 |
5.37 |
5.71 |
5.31 |
5.55 |
5.45 |
5.43 |
Rated heating capacity |
KW |
12.8 |
12.8 |
18.2 |
25.6 |
36.2 |
51.3 |
72.30 |
86.80 |
108.40 |
Rated input power for heating |
KW |
2.98 |
3.4 |
4.16 |
5.95 |
8.42 |
11.95 |
16.98 |
20.68 |
25.49 |
Rated input current for heating |
A |
15.1 |
6.4 |
8.66 |
11.8 |
17.56 |
23.7 |
35.12 |
42.14 |
52.68 |
Heating performance coefficient (COP) |
/ |
4.30 |
4.30 |
4.38 |
4.30 |
4.30 |
4.29 |
4.26 |
4.20 |
4.25 |
Use side heat exchanger water flow |
M3/h |
2.32 |
2.32 |
3.28 |
4.83 |
6.55 |
9.7 |
13.12 |
15.70 |
19.66 |
Heat source side heat exchanger water flow |
M3/h |
1.32 |
1.32 |
1.87 |
2.75 |
3.72 |
5.50 |
7.46 |
8.91 |
11.18 |
Ground source closed loop |
Rated cooling capacity |
KW |
12.98 |
12.98 |
18.36 |
25.01 |
36.63 |
50.00 |
73.30 |
87.85 |
109.50 |
Rated input power for cooling |
KW |
2.59 |
2.59 |
3.40 |
4.80 |
6.80 |
9.59 |
13.90 |
16.50 |
20.92 |
Rated input current for cooling |
A |
12.33 |
4.30 |
7.23 |
10.39 |
14.48 |
20.80 |
28.98 |
34.78 |
43.50 |
Cooling performance coefficient (EER) |
/ |
5.01 |
5.01 |
5.41 |
5.21 |
5.38 |
5.21 |
5.27 |
5.32 |
5.23 |
Rated heating capacity |
KW |
8.7 |
8.9 |
12.51 |
17.5 |
25.1 |
34.9 |
50.10 |
59.90 |
74.80 |
Rated input power for heating |
KW |
3.21 |
2.95 |
4.15 |
6.01 |
8.42 |
12.02 |
16.95 |
20.80 |
25.85 |
Rated input current for heating |
A |
15.34 |
6.1 |
9.43 |
13.05 |
19.14 |
30.20 |
38.30 |
45.95 |
57.70 |
Heating performance coefficient (COP) |
/ |
2.71 |
3.02 |
3.01 |
2.91 |
2.98 |
2.90 |
2.96 |
2.88 |
2.89 |
Use side heat exchanger water flow |
M3/h |
2.23 |
2.23 |
3.16 |
4.65 |
6.30 |
9.30 |
12.65 |
15.30 |
18.93 |
Heat source side heat exchanger water flow |
M3/h |
2.79 |
2.79 |
3.95 |
5.81 |
7.87 |
11.60 |
15.85 |
18.92 |
23.65 |
Power supply |
220V/50Hz |
3N 380V/50Hz |
Compressor |
Type |
Fully closed scroll type |
Quantity |
PCS |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
2 |
Heat source side heat exchanger |
Type |
Shell & tube heat exchanger |
Pipe size |
DN |
DN20 |
DN20 |
DN25 |
DN25 |
DN32 |
DN32 |
DN50 |
DN65 |
DN65 |
Use side heat exchanger |
Type |
Shell & tube heat exchanger |
Pipe size |
DN |
DN20 |
DN20 |
DN25 |
DN25 |
DN32 |
DN32 |
DN50 |
DN65 |
DN65 |
Protections |
|
|
|
|
|
|
|
|
|
Refrigerant |
Type |
R410A |
Quantity |
KG |
2 |
2 |
2.9 |
3 |
2.9x2 |
3.3x2 |
8x2 |
8.7x2 |
12x2 |
Unit dimensions |
Length |
MM |
810 |
810 |
810 |
810 |
1100 |
1100 |
1800 |
1800 |
1800 |
Width |
MM |
420 |
420 |
420 |
420 |
840 |
840 |
1150 |
1150 |
1150 |
Height |
MM |
590 |
590 |
590 |
590 |
800 |
800 |
1050 |
1050 |
1050 |
Noise |
≤DB(A) |
51 |
51 |
55 |
58 |
60 |
60 |
64 |
65 |
68 |
Weight |
KG |
115 |
115 |
120 |
180 |
190 |
700 |
730 |
780 |
850 |
Note: |
1. Underground water type cooling standard condition: use side water input/output temperature 12ºC/7ºC; source side water input/output temperature 18ºC/29ºC. Underground water type heating standard condition: use side water input/output temperature 40ºC/45ºC; source side water input/output temperature 15ºC/-a. |
2. Ground source closed loop type cooling standard condition: use side water input/output temperature 12ºC/7ºC; source side water input/output temperature 25ºC/30ºC Ground source closed loop type heating standard condition: use side water input/output temperature 40ºC/45ºC ; source side water input/output temperature 5ºC/-a. |
3. "-a " means the water flow under cooling standard condition. |
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret. |