Water Source Heat Pump with Tube Heat Exchanger

Product Details
Customization: Available
Certification: Ce, ISO, UL
Rated Heating Capacity: 8kw to 40kw
Still deciding? Get samples of US$ 3000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Water Source Heat Pump with Tube Heat Exchanger
  • Water Source Heat Pump with Tube Heat Exchanger
  • Water Source Heat Pump with Tube Heat Exchanger
  • Water Source Heat Pump with Tube Heat Exchanger
  • Water Source Heat Pump with Tube Heat Exchanger
  • Water Source Heat Pump with Tube Heat Exchanger
Find Similar Products

Basic Info.

Model NO.
CSFXRS-20II
Usage
Air Conditioner
Control Type
Digital
Display Type
LCD
Material
Stainless Steel
Transport Package
Safe Export Packing
Specification
1300mm*750mm*1050mm
Trademark
CEN Creative Power
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
5 Units/Day

Product Description

KONNEN WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, WITH COPELAND COMPRESSOR AND R410A REFRIGERANT:
* Panasonic compressor & R410a refrigerant or Copeland compressor & R410a refrigerant;
* Preservative oil for copper tubes and all important part of cabinet;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* KONNEN LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.


PARAMETERS TABLE:
W02H series (water source heat pump water heater)     
Model CSFXRS-8I CSFXRS-12I CSFXRS-20I CSFXRS-12II  CSFXRS-20II  CSFXRS-28II CSFXRS-40II CSFXRS-55II CSFXRS-80II CSFXRS-95II CSFXRS-120II CSFXRS-145II CSFXRS-190II
Rated heating capacity KW 8 12 20 12 20 28 40 55 80 95 120 145 190
Rated power KW 1.64  2.41  4.02  2.41  3.91  5.58  7.98  11.07  16.26  19.11  24.44  29.47  39.09 
Rated current A 7.11  10.48  17.46  4.56  7.38  10.54  15.09  20.92  30.73  36.13  46.19  55.70  73.89 
Maximum power KW 2.21  3.25  5.42  3.14  5.08  7.25  10.38  14.39  21.14  24.85  31.77  38.31  50.82 
Maximum current A 10.52  15.49  25.82  6.12  9.90  14.14  20.24  28.05  41.22  48.46  61.96  74.71  99.10 
Performance coefficient COP 4.89  4.98  4.98  4.97  5.12  5.02  5.01  4.97  4.92  4.97  4.91  4.92  4.86 
Rated hot water yields L/H 172 258  430  258  430  602  860  1182  1720  2043  2580  3118  4085 
Setting water temperature ºC 50ºC(default)  28-60ºC(adjustable)
Power supply 1N 220V/50Hz                                                      (Special power supply for option) 3N 380V/50Hz(Special power supply for option)
Compressor Type Hermetic Rotor type Hermetic scroll type
Start mode Direct(Soft start for option)
Application side heat exchanger Type Shell & tube heat exchanger(Tube in tube heat exchanger or Plate type heat exchanger for option) Shell & tube heat exchanger
Water flow M3/h 1.4 2.1  3.4  2.1  3.4  4.8  6.9  9.4  13.8  16.3  20.6  24.9  32.7 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70
Pipe connection DN DN20 DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN65 DN65
Pipe type Inner thread Flange
Heat source side heat exchanger Type Shell & tube heat exchanger
Water flow M3/h 1.1 1.6  2.7  1.6  2.7  3.8  5.4  7.3  10.7  12.7  16.1  19.4  25.5 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70
Pipe size DN DN20 DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN65 DN65
Connection type Inner thread Flange
Protections 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.
Refrigerant  Type R410A
Quantity(KG) 1.6 1.9 2.8 1.9 2.8 3 2.8x2 6.5x2 8x2 8.7x2 8x3 8.7x3 8.7x4
Noise DB(A) ≤52 ≤53 ≤55 ≤55 ≤55 ≤58 ≤58 ≤62 ≤65 ≤65 ≤70 ≤75 ≤75
Dimension mm 810x420x590 840x800x1430 1800x1150x1050
Net weight KG 55 68 95 65 95 135 195 320 795 885 985 1180 1210
Gross weight KG 65 78 105 75 105 145 215 340 830 920 1020 1215 1245
Note: 1. Hot water heating standard condition: use side initial water temperature 15ºC, end water temperature 55ºC;  heat source side water input temperature 15ºC.  
          2. The above parameters are based on refrigerant R410A, for parameters based on other refrigerant please contact us.
          3. The above parameters may have some differences from the final product because of products updating, please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

HEAT PUMP, WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, GROUND SOURCE HEAT PUMP, GEOTHERMAL HEAT PUMP.

PRODUCT FEATURES:
Water Source Heat Pump with Tube Heat Exchanger

HEAT PUMP, WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, BRINE TO WATER HEAT PUMP, GROUND SOURCE HEAT PUMP, GEOTHERMAL HEAT PUMP.


WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY 2017(HEAT PUMP + WATER TANK + CONTROLLER):

Water Source Heat Pump with Tube Heat Exchanger
WHY US:
Water Source Heat Pump with Tube Heat Exchanger
KONNEN NEW PROJECTS:
Water Source Heat Pump with Tube Heat ExchangerKONNEN HEAT PUMPS FOR EXPORTING:
Water Source Heat Pump with Tube Heat Exchanger

WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Water Source Heat Pump with Tube Heat Exchanger

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier