Customization: | Available |
---|---|
Heat Temperature: | 50-70°C |
Work Environment: | Low-temperature Heat Pump |
Still deciding? Get samples of US$ 598/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
|||||||||||||||||||||
Model Parameter | KFXRS-12IIL/d | KFXRS-19IIL/d | KFXRS-35IIL/d | KFXRS-120IIL/d | |||||||||||||||||
Rated Heating capacity (KW) | 12 | 19 | 35 | 120 | |||||||||||||||||
Rated outlet hot water quantity (L/H) | 257 | 408 | 760 | 2580 | |||||||||||||||||
Outlet water rated temp (°C) | 50 | 50 | 50 | 50 | |||||||||||||||||
Outlet water max temp (°C) | 55 | 55 | 55 | 55 | |||||||||||||||||
Working temeperature range(°C) | -20 to 43 | -20 to 43 | -20 to 43 | -20 to 43 | |||||||||||||||||
electricity parameter | Rated Power (KW) | 2.75 | 4.85 | 9.7 | 28 | ||||||||||||||||
Rated Current (A) | 5.2 | 9.1 | 21.4 | 91 | |||||||||||||||||
Max. Power (KW) | 3.72 | 7.7 | 12.7 | 52 | |||||||||||||||||
Max. Current (A) | 6.7 | 11.99 | 27.8 | 165 | |||||||||||||||||
Power Supply | 380V~3N/50HZ | 380V~3N/50HZ | 380V~3N/50HZ | 380V~3N/50HZ | |||||||||||||||||
Refrigerant | R22(2200g) | R22(3250g) | R22(3250*2g) | R22(3250*6g) | |||||||||||||||||
Dimensions (mm) | 700*700*870 | 840*840*1060 | 1450*910*1430 | 1200*2500*2050 | |||||||||||||||||
Pipe size (mm) | 2* DN20 | 2* DN32 | 2* DN40 | 2* DN90 | |||||||||||||||||
Circulation Water Flow (M3/h) | >2.58 | >3.4 | >7.52 | >20.64 | |||||||||||||||||
Weight KG | 103 | 165 | 267 | 855 | |||||||||||||||||
Waterproof grade | IPX4 | IPX4 | IPX4 | IPX4 | |||||||||||||||||
Defend electric shock grade | GRADE 1 | GRADE 1 | GRADE 1 | GRADE 1 | |||||||||||||||||
Noise Db | ≤58Db | ≤63Db | ≤68Db | ≤78dB | |||||||||||||||||
Compressor | Copeland | Copeland | Copeland | Copeland | |||||||||||||||||
Testing Conditions | Ambient Temperature | ||||||||||||||||||||
Dry Bulb Temp. | Wet Bulb Temp. | ||||||||||||||||||||
20°C | 15°C | ||||||||||||||||||||
1. EVI system for lowest temperature -25°C working. 2. Using the famous compressor, four-way valve,expansion valve 3. Microcomputer control, automatic cycle to maintain the temperature 4. Intelligent heat defrost,three sets of unique design of heat exchange, one set special for defrosting, to ensure constant hot water temperature. 5. Low noise, fin evaporator, hear transfer efficiency, corrosion-resistant. 6. Can be modular, multi-unit and joint control, hot water volume, water temperature constant |