Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling

Product Details
Customization: Available
Certification: SASO, CCC, ISO9001, CE, TUV
Working Medium: R410A
Still deciding? Get samples of US$ 1100/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
  • Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
  • Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
  • Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
  • Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
Find Similar Products

Basic Info.

Model NO.
RF6I/bd---RF20I/bd
Heat Source Type
Air Source Heat Pump
Product Name
Air to Water Heat Pump Water Heater
Rated Outlet Hot Water Temperature
55 Degree
Maximum Outlet Hot Water Temperature
56 Degree
Compressor
Gmcc
Refrigerant
R410A
Usage
Water Heater
Control Type
Digital
Display Type
LCD
Material
Colored Steel Casing
Working Range
-30--43 Degree
Power Supplier
220V/1/50Hz
Heating Capacity (Kw)
8.8kw-17kw
Power Input (Kw)
2.55-4.91
Cooling Capacity (Kw)
8-12
Cooling Input(Kw)
3.2-4.8
Transport Package
Safe Export Packing
Specification
RF8I/bd--RF16I/bd
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
2500units/Month

Product Description

KONNEN DC INVERTER AIR SOURCE HEAT PUMP, FOR COOLING +HEATING:
* Delivery time:about 30days after received deposit;
* Payment:T/T 30% prepaid ,then pay for the balance before delivery;
*Package:ply-wood cases;
* Warrenty:18month;

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /CoolingKONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
WHY US:
Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
KONNEN NEW PROJECTS:
Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
KONNEN HEAT PUMPS LOADING:
Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling
PARAMETERS TABLE:
POLESTAR series DC INVERTER MONOBLOCK TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER
Model RF6I/bd RF8I/bd RF12I/bd RF16I/bd RF20I/bd RF20II/bd
Power Supply V/Ph/Hz 220~240/1/50 380/3/50
Rated Condition 7ºC Heating Capacity (KW) 6.2 8.5 15 18 20 20
Power Input (KW) 1.88 2.66 4.36 5.21 5.88 5.88
COP 3.3 3.2 3.44 3.45 3.4 3.4
Nominal Condition -12ºC Heating Capacity (KW) 5 5.50 10.50 12.13 14.5 14.5
Power Input (KW) 2.17 2.33 4.40 5.05 6.01 6.02
COP 2.3 2.36 2.40 2.40 2.41 2.41
Low Temp. Condition -20ºC Heating Capacity (KW) 4.1 4.70 9.21 10.52 12.5 12.5
Power Input (KW) 2.16 2.47 4.56 5.18 6.25 6.25
COP 1.9 1.90 2.02 2.03 2 2
Low Temp. Condition -25ºC
/Water output temp. 41ºC
Heating Capacity (KW) 3.2 3.55 6.82 8.76 10.35 10.35
Power Input (KW) 2.1 2.20 4.21 5.03 6.02 6.02
COP 1.52 1.61 1.62 1.74 1.72 1.72
Low Temp. Condition -25ºC
/Water output temp. 50ºC
Heating Capacity (KW) 2.96 3.19 6.14 8.08 9.59 9.58
Power Input (KW) 2.17 2.28 4.23 5.69 6.81 6.81
COP 1.36 1.40 1.42 1.42 1.41 1.41
Rated Cooling Condition Cooling capacity (KW) 4.77 7.00 11.50 12.00 15.00 15.00
Power input (KW) 1.83 2.64 4.34 4.61 5.75 5.74
EER 2.6 2.65 2.65 2.60 2.61 2.61
Max. power input (KW) 2.7 4.4 5.2 6.6 7.1 8.5
Max. current Without E-heater (A) 12.5 20 23.7 30 32.5 15.5
Max. Water Output Temp. Under Ambient Temp. -25ºC 58 58 58 58 58 58
Water resistance (kPa) 30 35 38 43 54 50
Noise Level dB(A) 56.5 59.5 61.5 61.5 62 63
Refrigerant R410A R410A R410A R410A R410A R410A
Water Flow 0.86m³/h 0.95 m³/h 1.98 m³/h 2.06 m³/h 2.5m³/h 2.5m³/h
Pipe Size DN20 DN25
Dimensions(mm) 795*300*550 920*365*710 940*393*1373
Net Weight 45kg 60Kg 130kg 130kg 140kg 145kg
Testing Condition:
- Rated condition: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
Air Source DC Inverter Heat Pump Water Heater for Hot Water / Heating /Cooling

 