Water/Ground Source Heat Pump for Cooling&Heating

Product Details
Customization: Available
Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
Find Similar Products

Basic Info.

Model NO.
CRS-70II
Heat Source
Water-source
Application
Villa Family
Certification
CE, ISO9001, CCC
Product Name
Water/Ground Source Heat Pump for Cooling&Heating
Refrigerant
R410A
Cooling Capacity
60kw
Rated Heating Capacity
69kw
Compressor
SANYO
Power Supply
380V/50Hz
Transport Package
Safe Export Packing, with Pallet
Specification
CE
Trademark
CEN (Creative Power)
Origin
Zhejiang, China
HS Code
84189910
Production Capacity
5000 Units/Month

Product Description

Water/Ground Source Heat Pump for Cooling&HeatingWater/Ground Source Heat Pump for Cooling&HeatingWater/Ground Source Heat Pump for Cooling&HeatingGeothermal heat pump
1. Cooling, heating & dhw
2. Indoor installation
3. CE approve
4. Comfort, safe and high cop
Ground source heat pump

1) it can be worked as an air conditioner, and while the same time, it can provide you with hot water; Also can be worked separately, such as an air conditioner or water heater.

2) LCD display controller, easy and automatic control.

3) insufficient water flow protection of heat pump

4) high/low pressure protection of heat pump.

5) automatic reversing defrosting function enables, units to work reliably in hard winter.

6) unit runs automatically according to set water temperature.

7) qualified components: Branded compressor, emerson expansion valve, high efficient heat exchanger, durable and low noise fans.
water(ground) source heat pump cooling & heating
Modle   CRS-4I   CRS-8I CRS-12II CRS-20II CRS-40II   CRS-70II CRS-80II CRS-120II CRS-165II CRS-200II CRS-240II CRS-300II
Cooling capacity kW 4 8 12 20 40 60 80 120 165 200 240 300
Heating capacity kW 4.3 8.6 13 22 45 69 91 131 176 213 260 315
Cooling input power kW 0.8 1.6 2.5 4.1 8.3 12.7 16.6 25.3 32.3 39.2 47 58.8
heating input power kW 0.95 1.9 2.8 4.7 10.4 14.6 20.6 27.2 39.1 47.3 57.7 70
Cooling input current A 4.3 8.4 4.5 7.5 15 22.7 29.5 45.5 58 71 85 106
Heating input current A 5.1 10.1 5.2 8.5 18.6 27 37 50.3 71 86 106 127
Underground working condution Cooling capacity kW 3.9 7.7 11.5 19.5 38.4 57.6 76.9 115.3 158.6 192.3 230.7 288.4
Heating capacity kW 4.2 8.2 12.5 21.2 43.2 66.3 85.1 125.9 169.2 204.8 250 302.8
Cooling input power kW 0.81 1.6 2.4 4.1 8.2 12.4 16.7 24.9 32.3 39.2 47 58
Heating input power kW 0.93 1.8 2.7 4.8 10 15.4 20.3 29.2 41.2 49.9 60.9 73.8
Cooling input current A 4.2 8.5 4.5 7.5 15 23.5 31.5 46 60.2 72.9 86 105
Heating input current A 4.8 9.8 5.3 9.1 18 29.1 37.5 55.3 76.6 92.8 113.2 137
Underground circle type nominal working condition Cooling capacity kW 3.8 7.6 11.4 19.1 38 57 76.2 114.1 157 190.3 228.4 285.5
Heating capacity kW 4.1 8.1 12.3 20.9 42 65 80.1 124.6 167.5 202.3 247.5 299.8
Cooling input power kW 0.8 1.6 2.4 4.2 8.4 12.7 16.9 25.3 32.9 39.8 47.8 59.8
Heating input power kW 1.1 2.1 3.1 5.1 10.5 16.2 20 31.1 41.8 50.5 61.8 74
Cooling input current A 4.2 8.4 4.7 7.9 15.6 23.6 31.9 47 61.1 74 88 111
Heating input current A 5.7 11.1 5.8 9.6 18 30.1 37.8 57.8 77.7 93 114 139.3
Circle water working conditon Cooling capacity kW 3.6 7.2 10.9 18.1 36.2 54.3 72.4 108.7 149.5 181.3 217.5 271.9
Heating capacity kW 4.7 10.3 15.6 26.4 54.6 84.5 104 161.9 218 266 330 390
Cooling input power kW 0.95 1.9 2.9 4.8 9.5 14.2 19.1 28.6 36.4 44.2 53 66.3
Heating input power kW 1.04 2.3 3.4 6 12.1 18.7 23.1 35.9 43.6 53.2 66 78
Cooling input current A 5.1 10.3 5.6 9.3 17.6 26.4 36 53.1 67.7 82 98 123.3
Heating input current A 5.5 12.3 6.7 11.4 22.5 34.7 43 66.7 81 98 122.7 145
power 220V/50Hz 380V/50Hz
Compressor type Rotor Scroll Double-Screw-Refrigeration Compressors
NO. UNIT 1 1 1 1 1 2 2 2 1 1 1 1
Energy regulation % 0, 100 0, 100 0, 100 0, 100 0, 100 0, 50, 100 0, 50, 100 0, 50, 100 0, 25, 50, 75, 100
Heating source side heat exchanger  Type Plate type heat exchanger
  Horizontal type shell& tube heat exchanger
Underground water make cooling water flow m 3 /h 0.36 0.7 1 1.7 3.4 5.2 6.7 10.8 14.2 16 20 24
Underground water make heating  water flow m 3 /h 0.42 0.83 1.3 2.1 4.2 6.2 8.3 12.4 17 21 25 31
Underground circle type nominal working condition cooling water flow m 3 /h 0.7 1.4 2.2 3.6 7.2 11.2 13.7 21.4 28.8 35 42 52
Underground circle type nominal working condition heating water flow m 3 /h 0.65 1.3 1.96 3.3 6.5 9.8 13.1 19.6 27 33 39.5 49
Water tube interface mm DN20 DN20 DN20 DN25 DN40 DN50 DN80 DN100
User side heat exchanger Type Plate type heat exchanger   Horizontal type shell& tube heat exchanger
cooling water flow m3/h 0.7 1.4 2.1 3.4 6.8 10.3 13.7 20 28.3 34.4 41.3 52
Heating water flow m3/h 0.74 1.5 2.2 3.8 7.7 11.8 15.6 22.5 30 36.6 44.7 54.2
Water tube interface mm DN20 DN20 DN20 DN25 DN40 DN50 DN80 DN100
Protector 1\High and low pressure protection, 2\anti-freeze protection, 3\temperature protection, 4\safety valve, 5\overload protection, 6\Reverse phase,
7\Lack of phase, 8\Separation of water and electricity, ect.
Refrigerant Type R410a/R407c
Throttle Mode thermostatic expansion valve
weight kg 0.8 1.2 1.9 3 12 19 23 39 45 56 67 82
Size Long mm 709 709 709 810 1760 2400 2400 2560 2560 2650 2890 2890
Wide mm 359 359 359 420 500 650 650 880 900 900 900 1100
High mm 592 592 592 590 1150 1210 1260 1300 1335 1430 1430 1530
Noise ≤ dB(A) 35 35 38 42 55 60 60 62 65 66 66 68
Weight kg 43.8 45 69 93 340 570 612 850 1150 1300 1450 1850
Note: 1, Underground circle type nominal cooling working condition: User side water inlet/outlet temperature 12º C/7º C; Source side water inlet/outlet temperature 25º C/30º C













              Underground circle type nominal Heating working condition: User side water inlet/outlet temperature 40º C/45º C; Source side water inlet/outlet temperature 10º C/5º C













        2, Underground water type nominal cooling workingcondition: user side water inlet/outlet temperature 12º C/7º C; source side water inlet/outlet temperature 18º C/29º C













              Underground water type nominal heating workingcondition: user side water inlet/outlet temperature 40º C/45º C; source side water inlet/outlet temperature 15º C/7º C













        3, Circle water type nominal cooling workingcondition: user side water inlet/outlet temperature 12º C/7º C; source side water inlet/outlet temperature 30º C/35º C













              Circle water type nominal heatinging workingcondition: user side water inlet/outlet temperature 40º C/45º C; source side water inlet/outlet temperature 20º C/15º C













        4, Standard cooling working condition: User side water inlet/outlet temperature 12º C/7º C; Source side water inlet/outlet temperature 15º C/20º C













            Standard heating working condition: User side water inlet/outlet temperature 40º C/45º C; Source side water inlet/outlet temperature 15º C/10º C













      5, The above parameters based on Refrigearnt R22, for parameters based on other refrigerants please contact us.













      6, The product parameters may have some difference from the final product because of products updating, please refer to final product label when buy. Our company keeps the right to interpret.