Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)

Product Details
Customization: Available
Certification: CCC, ISO9001, CE
Product Name: Commercial Use Air Source Heat Pump (Ckfyrs-35II)
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
  • Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
  • Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
  • Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
  • Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
  • Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
Find Similar Products

Basic Info.

Model NO.
HW10P
Rated Outlet Hot Water Temperature
55 Degree
Maximum Outlet Hot Water Temperature
60 Degree
Compressor
SANYO
Refrigerant
R410A
Usage
Heat Pump
Control Type
Digital
Display Type
LCD
Material
Stainless Steel
Transport Package
Safe Export Packing
Trademark
KONNEN
Origin
China
HS Code
8418612090
Production Capacity
3, 000PCS/Month

Product Description

KONNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
WHY US:
Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
KONNEN NEW PROJECTS:
Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
KONNEN HEAT PUMPS LOADING:
Commercial Use Air Source Heat Pump Water Heater for Hotel /Hospital / School (HW10P)
PARAMETERS TABLE:

 A02H series (Air source heat pump water heater circulation type)                                                                                                                                          
  HW03Ps-E3 HW05Ps-E5 HW03P-E3  HW05P-E5 HW07P-E5 HW10P-C24 HW14P-C24 HW20P-C48 HW24P-C48 HW30P-C48 HW36P-C48 HW48P-C96
Rated heating capacity kW 12 19 12 19 25 35 50  75 85 105 125 165
Rated input power kW 2.75  4.39  2.75  4.37  5.75  8.10  11.57  17.20  19.60  24.20  28.90  38.10 
Rated input current A 14.05  23.10  5.17  8.34  10.77  15.00  23.86  31.80  37.00  46.10  53.50  72.30 
Maximum input power kW 3.38  5.40  3.38  5.38  7.07  9.96  14.23  21.16  24.11  29.77  35.55  46.86 
Maximum input current A 18.28  29.19  6.43  10.21  13.44  18.93  27.05  40.20  45.81  56.56  67.54  89.04 
Performance coefficient(COP) / 4.36  4.33  4.36  4.35  4.35  4.33  4.32  4.36  4.34  4.34  4.33  4.33 
Rated hot water output temp. ºC 55 
Max. hot water output temp. ºC 60 
Rated hot water produce capacity L/H 258 408 258 408 537 752.5 1075 1612.5 1827.5 2257.5 2687.5 3547.5
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Fully closed scroll type
Start Mode Directly start
Quantity Set 1 1 1 1 1 2 2 4 2 3 3 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 2.1  3.3  2.1  3.3  4.3  6.0  8.6  12.9  14.6  18.1  21.5  28.4 
Water Pressure Drop kPa ≤50 ≤55 ≤50 ≤55 ≤55 <60 <60 <65 <65 <65 <65 <65
Pipe size DN DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN65 DN80
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Refrigerant Throttle Type Electronic expansion valve
Quantity kg 1.9 2.8 1.9 2.8 4.1 2.8×2 4.1×2 3.2×4 7.6×2 6.2×3 7.6×3 7.6×4
Noise DB(A) ≤55 ≤63 ≤55 ≤63 ≤65 ≤65 ≤68 ≤70 ≤72 ≤73 ≤74 ≤78
Dimension mm 700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1060
1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1980 1000×2050×1980 2000×2050×1980
Net Weight kg 100 160 100 160 190 310 400 605 650 835 840 1230
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. 
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier