• Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
  • Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
  • Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
  • Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
  • Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
  • Geothermal Source/Water Source Heat Pump Water Heater Ce Approved

Geothermal Source/Water Source Heat Pump Water Heater Ce Approved

Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Heat Source: Water-source
Heating Type: Circulating Heat
Application: Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Customization:

Contact Supplier

Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
W02H
Certification
CE
Transport Package
Safe Packing Export, with Pallet
Specification
CE, CCC, ISO9001, TUV
Trademark
KONNEN or OEM
Origin
Zhejiang, China
HS Code
8418612090
Production Capacity
1500unit/Month

Product Description

KONNEN WATER SOURCE HEAT PUMP, WATER TO WATER HEAT PUMP, GEOTHERMY /GROUND SOURCE:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R417a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* "Schneider" AC contactor & Relay
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
WHY US:
Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
KONNEN NEW PROJECTS:
Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
KONNEN HEAT PUMPS LOADING:
Geothermal Source/Water Source Heat Pump Water Heater Ce Approved
PARAMETERS TABLE:
Geothermy series (Water / Ground source heat pump water heater)
  CSFXRS-8I CSFXRS-10I CSFXRS-12I CSFXRS-20II CSFXRS-12II CSFXRS-20II CSFXRS-28II CSFXRS-40II CSFXRS-55II CSFXRS-80II CSFXRS-95II CSFXRS-120II CSFXRS-160II CSFXRS-190II CSFXRS-240II
Rated heating capacity KW 7.9 9.8 11.8 19.8 11.9 19.8 28.1 39.5 54.3 79.2 93.95 118.85 158.2 188.8 238.4
Rated power KW 1.64  2.03  2.45  4.09  2.45  4.09  5.79  8.18  11.28  16.45  19.57  24.61  32.75  38.92  49.36 
Rated current A 8.77  11.53  13.92  23.24  4.62  7.77  10.99  15.54  21.97  31.12  37.16  46.74  62.19  73.92  93.75 
Maximum power KW 2.21  2.71  3.25  5.42  3.28  5.52  7.81  11.04  15.22  22.14  26.42  33.22  44.22  52.51  66.63 
Maximum current A 11.82  15.32  17.38  30.79  6.23  10.48  14.83  20.97  29.65  41.99  50.51  63.09  83.98  99.72  126.55 
Performance coefficient COP 4.82  4.83  4.82  4.84  4.86  4.84  4.85  4.83  4.81  4.81  4.80  4.83  4.83  4.85  4.83 
Rated hot water produce capacity L/H 172 215 258  430  258  430  602  860  1182  1720  2043  2580  3440  4085  5150 
Rated hot water output tempemperature ºC 55
Maximum hot water output temperature ºC 60
Power supply 1N 220V~240V/50Hz 3N 380V~420V/50Hz
Compressor Type Rotor type Hermetic scroll type
Start mode Directly Start(Soft start for option)
Hot water side heat exchanger Type Shell & tube heat exchanger
Water flow M3/h 1.4 1.8 2.1  3.4  2.1  3.4  4.8  6.9  9.4  13.8  16.3  20.6  27.5  32.7  41.2 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70 ≤70
Pipe connection DN DN20 DN20 DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN80 DN80 DN80
Pipe type Inner thread Flange
Heat source side heat exchanger Type Plate type heat exchanger Tube in tube heat exchanger Shell & tube heat exchanger
Water flow M3/h 1.1 1.4 1.6  2.7  1.6  2.7  3.8  5.4  7.3  10.7  12.7  16.1  21.5  25.5  32.3 
Water pressure drop KPa ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤50 ≤60 ≤60 ≤70 ≤70 ≤70 ≤70 ≤70
Pipe size DN DN20 DN20 DN20 DN25 DN20 DN25 DN25 DN32 DN50 DN50 DN50 DN65 DN80 DN80 DN80
Pipe connection Inner thread Flange
Protections 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.
Refrigerant Type R410A
Quantity(KG) 1.2 1.3 1.7 2.8 1.7 2.6 3.8 2.6x2 3.8x2 6x2 7.2x2 9x2 6x4 7.5x4 9x4
Noise ≤DB(A) 51 51 52 55 52 55 58 58 62 64 65 68 71 72 73
Unit dimensions Length MM 706 706 956 956 956 956 956 1100 1100 1795 1795 1795 2752 2752 2752
Width MM 356 356 556 556 556 556 556 840 840 1116 1116 1116 1178 1178 1178
Height MM 591 591 680 680 680 680 680 800 800 1049 1049 1049 1201 1201 1201
Weight KG 55 58 65 93 65 93 128 180 220 700 730 780 1300 1400 1500
Note: 1. Hot water heating standard condition: Hot water side initial water temperature 15ºC, final water temperature 55ºC;  heat source side water input temperature 15ºC.
2. The above parameters are based on refrigerant R410A, for parameters based on other refrigerant please contact us.