Super Low Temperature Air to Water Heat Pump Water Heater

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 40~60 Deg C
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • Super Low Temperature Air to Water Heat Pump Water Heater
  • Super Low Temperature Air to Water Heat Pump Water Heater
  • Super Low Temperature Air to Water Heat Pump Water Heater
  • Super Low Temperature Air to Water Heat Pump Water Heater
  • Super Low Temperature Air to Water Heat Pump Water Heater
  • Super Low Temperature Air to Water Heat Pump Water Heater
Find Similar Products

Basic Info.

Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB, RoHS, SASO
Product Name
Commercial Use Air Source Heat Pump (Ckfxrs-70II)
Rated Heating Capacity
12kw~145kw
Suitable Environment
-25~43
Color
Dark Black-Grey
Controller
Konnen Brand
Testing
25HP National Proved Laboratory
Transport Package
Plywood Case with Pallet
Specification
Standard
Trademark
KONNEN
Origin
China (Mainland)
HS Code
8418612090
Production Capacity
500 Units/Month

Product Description

Low working ambient temperature of EVI air to water heat pump for water heating, room heating, EVI air source heat pump, with Copeland compressor and R410a refrigerant, SWEP plate type heat exchanger, lowest working temperature can reach -25 deg C.
* Copeland compressor & R410a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* "SWEP" plate type heat exchanger;
* Chinese No.1 brand "Sanhua" 4-way valve;
* Schneider AC contactor and relay;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* KONNEN LCD controller;
* Delivery time: 25~30 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Super Low Temperature Air to Water Heat Pump Water Heater
WHY US:
Super Low Temperature Air to Water Heat Pump Water Heater
KONNEN NEW PROJECTS:
Super Low Temperature Air to Water Heat Pump Water Heater
WORLD FAMOUS BRAND WE COOPERATED FOR OUR HEAT PUMPS:
Super Low Temperature Air to Water Heat Pump Water Heater
HEAT PUMP LOADING:
Super Low Temperature Air to Water Heat Pump Water Heater
PRODUCT FEATURES:
Super Low Temperature Air to Water Heat Pump Water Heater

PARAMETERS TABLE:
A02U series( EVI air source heat pump low temperature type)                                                                                                   EVI-150307
  EVI3P-S5 EVI5P-S5 EVI10P-C24 EVI15P-C24 EVI20P-C48 EVI30P-C48 EVI40P-C96
Normal condition Heating capacity kW 12 19 36 55 75 105 145
Input power kW 2.80  4.40  8.20  12.70  17.10  24.10  33.20 
Input current A 5.30  8.60  14.80  24.20  33.00  45.10  62.50 
COP / 4.29  4.32  4.39  4.32  4.39  4.36  4.37 
Nominal condition Rated heating capacity kW 9.50  15.00  30.00  45.00  60.00  90.00  120.00 
Rated input power kW 2.60  4.10  8.10  12.20  16.10  24.50  32.50 
Rated input current A 5.20  8.20  15.30  23.10  30.20  46.00  61.10 
COP / 3.65  3.66  3.70  3.68  3.73  3.67  3.69 
Low temperature condition Heating capacity kW 5.50  8.80  17.50  15.30  36.50  52.50  70.00 
Input power kW 2.26  3.65  7.30  6.41  15.10  21.60  29.10 
Input current A 4.29  6.93  13.00  12.10  28.10  40.80  54.80 
COP / 2.43  2.41  2.40  2.39  2.42  2.43  2.41 
Maximum input power/current kW/A 3.61/6.92 5.71/11.20 10.62/20.75 16.52/32.23 22.27/43.36 31.38/612 42.92/83.62
Rated hot water output temperature ºC 55
Maximum hot water output temperature ºC 60
Rated hot water produce capacity L/H 204.25 322.5 645 967.5 1290 1935 2580
Power supply 3N 380V/50Hz
Compressor Type Hermetic scroll type
Start mode Directly start
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow M3/h 2.1  3.3  6.0  9.5  12.9  18.0  24.9 
Water pressure drop KPa 50 55 60 60 65 65 65
Pipe size DN 25 25 32 32 50 65 65
Middle heat exchanger Type Brazed plate type heat exchanger
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Noise DB(A) 55 58 65 68 70 73 74
Unit dimensions mm 835×410×1330 1000×1000×1858 1000×2050
×1900
1000×2050
×1980
2000×2050
×1980
Weight KG 115 175 355 425 620 855 1250
Testing condition: 1. Normal condition: dry bulb 20ºC, wet bulb 15ºC; initial water temperature 15ºC, end water temperature 55ºC.
                          2. Nominal condition: dry bulb 7
ºC, wet bulb 6ºC; initial water temperature 9ºC, end water temperature 55ºC.
                          3. Low temperature condition: dry bulb -12
ºC, wet bulb -14ºC; initial water temperature 9ºC, end water temperature 55ºC.

 
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier