Basic Info
  • Model NO.: CSFXRS-55II
  • Heat Temperature: 50-70°C
  • Heat Source: Water-source
  • Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
  • Product Name: Water to Water Heat Pump (Csfxrs-20II)
  • Compressor: SANYO or Copeland
  • Maximum Hot Water Outlet Temperature: 60
  • Type: Water to Water Heat Pump
  • Specification: water to water heat pump
  • HS Code: 8418612090
  • Energy Efficiency Grade: One
  • Work Environment: Common Heat Pump
  • Heating Type: Circulating Heat
  • Certification: CE, ISO9001, CCC, SASO, TUV
  • Hot Water Heating Capacity: 55kw
  • Refrigerant: R410A/R417A
  • Rated Hot Water Outlet Temperature: 55
  • Trademark: KONNEN
  • Origin: China
Product Description

Water to water heat pump water heater
Tested in national proved 25HP laboratory
With CE approved
Applications: Room heaing or domestic hot water
With Famouns brand components such as Copeland compressor, Saginomiya electronic expansion valve, Sanhua 4-way valve and etc..

CE approved
Long time of warranty
Machine casing: spray coating metal plate
Function: Production of hot water
Host machine color:  grey
Accessories: LCD controller, pressurized water tank(150L, 200L, 300L, 500L)
Safety protecting system:
1)High and low pressure protection
2)Anti-freeze protection
3)High temperature protection
4)Safety valve
5)Overload protection
6)Reverse phase
7)Lack of phase
8)Separation of water and electricity
Refrigerant: R22/R410A/R417a

W02H series (water source heat pump water heater)                                                                                                                                                                                                                                                       RYF-CW02HCY01-130514
 CSFXRS-8ICSFXRS-12ICSFXRS-20ICSFXRS-12II CSFXRS-20II CSFXRS-28IICSFXRS-40IICSFXRS-55IICSFXRS-80IICSFXRS-95IICSFXRS-120IICSFXRS-145IICSFXRS190II
CW02H020ACW02H030ACW02H050ACW02H030BCW02H050ACW02H070ACW02H100ACW02H140ACW02H200ACW02H240ACW02H300ACW02H360ACW02H480A
Rated heating capacityKW8122012202840558095120145190
Rated powerKW1.62.4 4.2 2.5 4.2 5.6 9.0 11.6 16.0 19.4 24.9 29.6 38.8 
Rated currentA8.412.8 21.7 4.7 7.8 10.5 16.0 20.9 30.1 36.4 46.1 55.6 72.9 
Maximum powerKW2.23.3 5.6 3.4 5.6 7.6 11.9 15.0 21.6 26.2 33.6 39.9 52.3 
Maximum currentA11.417.2 29.3 6.4 10.6 14.3 23.8 26.8 40.8 49.4 60.6 75.5 98.9 
Performance coefficientCOP5.0 4.9 4.8 4.8 4.8 5.0 4.4 4.7 5.0 4.9 4.8 4.9 4.9 
Rated hot water produce capacityL/H172258 430 258 430 602 860 1182 1720 2043 2580 3118 4085 
Rated hot water output tempemperatureºC55
Maximum hot water output temperatureºC60
Power supply1N 220V/50Hz3N 380V/50Hz
CompressorTypeRotor typeFully colsed scroll type
Start modeDirect
Use side heat exchangerTypeShell & tube heat exchanger
Water flowM3/h1.42.1 3.4 2.1 3.4 4.8 6.9 9.4 13.8 16.3 20.6 24.9 32.7 
Water pressure dropKPa≤50≤50≤50≤50≤50≤50≤50≤60≤60≤70≤70≤70≤70
Pipe connectionDNDN20DN20DN25DN20DN25DN25DN32DN50DN50DN50DN65DN65DN65
Pipe type Inner threadFlange
Heat source side heat exchangerTypeShell & tube heat exchanger
Water flowM3/h1.11.6 2.7 1.6 2.7 3.8 5.4 7.3 10.7 12.7 16.1 19.4 25.5 
Water pressure dropKPa≤50≤50≤50≤50≤50≤50≤50≤60≤60≤70≤70≤70≤70
Pipe sizeDNDN20DN20DN25DN20DN25DN25DN32DN50DN50DN50DN65DN65DN65
Pipe connectionInner threadFlange
Protections1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.
Refrigerant TypeR410A
Quantity(KG)1.61.92.81.92.832.8x26.5x28x28.7x212x27.8x48.7x4
Noise≤DB(A)51525552555858626465687072
Unit dimensionsLengthMM71081081081081081084084018001800180020002000
WidthMM36042042042042042080080011501150115012001200
HeightMM5905905905905905901430143010501050105010001000
WeightKG5565936593128180220700730780850880
Note: 1. Hot water heating standard condition: use side initial water temperature 15ºC, end water temperature 55ºC;  heat source side water input temperature 15ºC.  
    2. The above parameters are based on refrigerant R410A, for parameters based on other refrigerant please contact us.
   3.  The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.

Water to water heat pump, water source heat pump, ground source heat pump, geothermal heat pump, brine to water heat pump
Send your message to this supplier
Avatar
Ms. Nico Yuan
sales manager
*From:
To: Ms. Nico Yuan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now