New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature

Product Details
Customization: Available
Certification: CCC, ISO9001, CE, ERP
Working Medium: 134A
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
195
Year of Establishment
2006-05-25
  • New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
  • New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
  • New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
  • New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
  • New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
  • New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
Find Similar Products

Basic Info.

Model NO.
HW HT
WiFi
Yes
Functions
Hot Water
Transport Package
Carton + Pallet
Specification
10~20kw
Trademark
KONNEN
Origin
Zhejiang, China
HS Code
8418612090
Production Capacity
3000 Units/Month

Product Description

New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High TemperatureHigh temperature air to water heat pump water heater, with Copeland compressor and R134a refrigerant, lowest working temperature can reach -15 deg  C, max. water output temperature 60 deg C/80 deg C.
* R410a refrigerant for HotSping series   &  R134a refrigerant for Volcano series;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "ND" shell & tube heat exchanger;
* "Sanhua" 4-way valve;
* KONNEN LCD controller;
* Delivery time: 25~30 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

PRODUCT FEATURES:
New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature

PARAMETERS TABLE:  
 HOTSPRING series (Air source heat pump water heater circulation type)       60ºC                                                                                  
  HW03Ps-E3 HW05Ps-E5 HW03P-E3  HW05P-E5 HW07P-E5 HW10P-C24 HW14P-C24 HW20P-C48 HW24P-C48 HW30P-C48 HW36P-C48 HW48P-C96
Rated heating capacity kW 12 19 12 19 25 35 50  75 85 105 125 165
Rated input power kW 2.75  4.39  2.75  4.37  5.75  8.10  11.57  17.20  19.60  24.20  28.90  38.10 
Rated input current A 14.05  23.10  5.17  8.34  10.77  15.00  23.86  31.80  37.00  46.10  53.50  72.30 
Maximum input power kW 3.38  5.40  3.38  5.38  7.07  9.96  14.23  21.16  24.11  29.77  35.55  46.86 
Maximum input current A 18.28  29.19  6.43  10.21  13.44  18.93  27.05  40.20  45.81  56.56  67.54  89.04 
Performance coefficient(COP) / 4.36  4.33  4.36  4.35  4.35  4.33  4.32  4.36  4.34  4.34  4.33  4.33 
Rated hot water output temp. ºC 55 
Max. hot water output temp. ºC 60 
Rated hot water produce capacity L/H 258 408 258 408 537 752.5 1075 1612.5 1827.5 2257.5 2687.5 3547.5
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Hermetic scroll type
Start Mode Directly start
Quantity Set 1 1 1 1 1 2 2 4 2 3 3 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 2.1  3.3  2.1  3.3  4.3  6.0  8.6  12.9  14.6  18.1  21.5  28.4 
Water Pressure Drop kPa ≤50 ≤55 ≤50 ≤55 ≤55 <60 <60 <65 <65 <65 <65 <65
Pipe size DN DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN65 DN80
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Refrigerant Throttle Type Electronic expansion valve
Quantity kg 1.9 2.8 1.9 2.8 4.1 2.8×2 4.1×2 3.2×4 7.6×2 6.2×3 7.6×3 7.6×4
Noise DB(A) 55 63 55 63 65 65 68 70 72 73 74 78
Dimension mm 700×680×
875
820×695×
1060
700×680×
875
820×695×
1060
820×695×
1060
1000×1000×1858 1000×1000×1858 1000×2050×1900 1000×2050×1900 1000×2050×1980 1000×2050×1980 2000×2050×1980
Net Weight kg 100 160 100 160 190 310 400 605 650 835 840 1230
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

VOLCANO SERIES (High temperature air source heat pump water heater circulation type)      80ºC                                                                                                     
  HT3Ps-T3 HT5sP-T5 HT3P-T3 HT5P-T5 HT7P-T5 HT10P-C24 HT14P-C24 HT20P-C48 HT24P-C48 HT30P-C48 HT36P-C48 HT48P-C96
Rated heating capacity kW 8 13.5 8 13.5 18 26 35 55 65 80 95 130
Rated input power kW 2.2 3.65 2.19  3.66  4.96  7.11  9.62  14.91  17.81  21.98  26.03  35.81 
Rated input current A 9.58 15.9 4.14  6.92  9.37  13.55  18.17  28.17  33.66  41.54  49.19  67.69 
Maximum input power kW 2.86 4.75 2.74  4.58  6.20  8.89  12.02  18.63  22.26  27.47  32.53  44.77 
Maximum input current A 14.92 24.77 5.34  8.92  12.09  17.33  23.44  36.33  43.41  53.57  63.44  87.29 
Performance coefficient(COP) / 3.63 3.69 3.65  3.69  3.63  3.65  3.64  3.69  3.65  3.64  3.65  3.63 
Rated hot water output temp. ºC 75
Maximum hot water output temp. ºC 80
Rated hot water produce capacity t40 L/H 172.0  290.2  172.0  290.3  387.0  559.0  752.5  1182.5  1397.5  1720.0  2042.5  2795.0 
t60 L/H 114.7  193.5  114.7  193.5  258.0  372.7  501.7  788.3  931.7  1146.7  1361.7  1863.3 
Power supply 1N 220V/50Hz 3N 380V/50Hz
Compressor Type Hermetic scroll type
Start Mode Directly start
Quantity Set 1 1 1 1 1 2 2 4 2 3 3 4
Water side heat exchanger Type Shell & coil(tube) heat exchanger
Water flow m3/h 1.4  2.3  1.4  2.3  3.1  4.5  6.0  9.5  11.2  13.8  16.3  22.4 
Water Pressure Drop kPa ≤45 ≤53 <50 <55 <57 <60 <60 <65 <65 <65 <65 <65
Pipe size mm DN20 DN25 DN20 DN25 DN25 DN32 DN32 DN50 DN50 DN50 DN65 DN80
Protections 1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection, etc.. 
Refrigerant Type R134a
Throttle Type Electronic expansion valve
Quantity kg 2.1 3.3 2.1 3.3 4.3 2.8×2 4.1×3 3.2×4 7.6×2 6.2*3 7.6×3 7.6×4
Noise DB(A) 55 63 55 63 65 65 68 70 72 73 74 78
Dimension mm 700×680×
875
860×820×
1080
700×680×
875
860×820×
1080
860×820×
1080
1000×1000×
1858
1000×1000×
1858
1000×2050×
1900
1000×2050×
1900
1000×2050×
1980
1000×2050×
1980
2000×2050×
1980
Net Weight kg 100 170 100 170 190 310 410 605 650 835 840 1250
Testing conditions: 
1. Application side initial water temperature: 15ºC, end temperature 75ºC, max. temperature 80ºC.
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC
The above parameters are based on Refrigearnt R134a, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any  business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
WHY CHOOSE US:
New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
KONNEN NEW PROJECTS:
New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
WORLD FAMOUS BRAND WE COOPERATED FOR OUR HEAT PUMPS:
New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
HEAT PUMP LOADING:
New Design Hot Selling Max 80 Degree C Air to Water Heat Pump High Temperature
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier